Product Details | ELECTRONIC TEST DIGITAL DATA ANALYZER

6625-01-530-9320 An instrument designed to receive and process digital signals from associated components in order to perform analysis of logic states, timing functions and microprocessor control. May include a display screen and/or triggering capabilities.

Part Alternates: CALYS 5, CALYS5, 6625-01-530-9320, 01-530-9320, 6625015309320, 015309320

Instruments and Laboratory Equipment | Electrical and Electronic Properties Measuring and Testing Instruments

Supply Group (FSG) NSN Assign. NIIN
66 16 JUN 2005 01-530-9320

Cross Reference | NSN 6625-01-530-9320

Part Number Cage Code Manufacturer
CALYS 5 08086 WAHL INSTRUMENTS, INC. DBA PALMER WAHL INSTRUMENTATION

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 6625-01-530-9320

Technical Data | NSN 6625-01-530-9320

Characteristic Specifications
DC VOLTAGE RATING 12.0 VOLTS NOMINAL
INTERNAL BATTERY ACCOMMODATION INCLUDED
OVERALL WIDTH 5.669 INCHES NOMINAL
OVERALL HEIGHT 2.362 INCHES NOMINAL
OVERALL LENGTH 10.236 INCHES NOMINAL
SPECIAL FEATURES DESIGNED FOR CHECKING EQUIPMENT IN TELEMETRY LOOPS, IE., SENSORS, TRANSMITTERS, POSITIONERS, CONVERTORS AND CONTROLLERS; MAX PERMISSIBLE COMMON MODE VOLTAGE IS 250 V RMS; ALPHANUMERIC DISPLAY; STORES UP TO 1000 MEASUREMENTS IN ONE OR MORE BURSTS
III END ITEM IDENTIFICATION GROUND SUPPORT EQUIPMENT
III PART NAME ASSIGNED BY CONTROLLING AGENCY ON SITE TESTER CALIBRATOR

Restrictions/Controls & Freight Information | NSN 6625-01-530-9320

Category Code Description
Shelf-Life Code:0Nondeteriorative
Hazardous Material Indicator CodePThere is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product
Demilitarization Code:ANon-Munitions List Item/ Non-Strategic List Item - Demilitarization not required.
Controlled Inventory Item Code:UUNCLASSIFIED
Precious Metals Indicator Code:AItem does not contain precious metal
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Automatic Data Processing Equipment:0Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)
Category Code Description
No Freight Information