NSN 6625-01-516-5522 TDS 2014 , TDS2014, 01-516-5522
Product Details | OSCILLOSCOPE
6625-01-516-5522 A test instrument which is designed to give visual indications on an LCD display or a cathode ray tube of instantaneous values and variations in electrical voltage. It can also be used to indicate any quantity which can be converted into terms of electrical potential. It may include an integral pulse generator, the output of which can be used to trigger an external component; be triggered by pulses from an external source, or it may utilize an LCD display or a special type of multigun cathode ray tube and circuitry which permits a trace(s) to be sustained and displayed indefinitely, and the trace(s) may be erased when desired. For items which are not separable and operable when detached from equipment of which they are a part (built into operational equipment), see INDICATOR (2) (as modified); MONITOR (as modified); and RECORDER (as modified). See also OSCILLOGRAPH.
Part Alternates: TDS 2014 , TDS2014, 6625-01-516-5522, 01-516-5522, 6625015165522, 015165522
Instruments and Laboratory Equipment | Electrical and Electronic Properties Measuring and Testing Instruments
Supply Group (FSG) | NSN Assign. | NIIN | Item Name Code (INC) |
---|---|---|---|
66 | 09 JAN 2004 | 01-516-5522 | 00357 ( OSCILLOSCOPE ) |
Demand History | NSN 6625-01-516-5522
Part Number | Request Date | QTY | Origin |
---|---|---|---|
6625-01-516-5522 | 2021-03-74 | 3 | United States |
Request a Quote
What Our Customers Say
Compare
Related Products | NSN 6625-01-516-5522
Technical Data | NSN 6625-01-516-5522
Characteristic | Specifications |
---|---|
BEAM QUANTITY | 4 |
SWEEP CIRCUITS | NOT INCLUDED |
AMPLIFIER DEFLECTION SENSITIVITY PROVISION | NOT PROVIDED |
INPUT INTENSITY MODULATION FEATURE | NOT PROVIDED |
PLATE DIRECT CONNECTION DEFLECTION SENSITIVITY PROVISION | NOT PROVIDED |
FREQUENCY RESPONSE RATING | NOT PROVIDED |
AMPLIFIER INPUT IMPEDANCE RATING PROVISION | NOT PROVIDED |
CALIBRATED SCREEN SCALE | NOT INCLUDED |
TRACE STORAGE TUBE | NOT INCLUDED |
CAMERA RECORDING DEVICE ACCOMMODATION | NOT PROVIDED |
CURRENT TYPE | AC |
VOLTAGE RATING | 300.0 VOLTS NOMINAL |
FREQUENCY RATING | 100.0 MEGAHERTZ NOMINAL |
OVERALL LENGTH | 323.8 MILLIMETERS NOMINAL |
OVERALL WIDTH | 151.4 MILLIMETERS NOMINAL |
OVERALL HEIGHT | 124.5 MILLIMETERS NOMINAL |
ACCESSORY COMPONENTS AND QUANTITY | P2200 200MHZ 10X - 1X SWITCHABLE PASSIVE PROBES ONE PER CHANNEL |
SPECIAL FEATURES | RECORD LENGTH 2.5 K POINTS; VERTICAL RESOLUTION EIGHT BITS; DISPLAY PASSIVE COLOR LCD WITH COLOR ON BLACK BACKROUND WITH ADJUSTABLE MULTI LEVEL CONTRAST |
III PART NAME ASSIGNED BY CONTROLLING AGENCY | DIGITAL STORAGE OSCILLOSCOPES |
Restrictions/Controls & Freight Information | NSN 6625-01-516-5522
Category | Code | Description |
---|---|---|
Shelf-Life Code: | 0 | Nondeteriorative |
Hazardous Material Indicator Code | P | There is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product |
Demilitarization Code: | D | Munitions List Item or Commerce Control List Item. Demilitarization required. Total destruction of the item and components so as to preclude restoration or repair to a usable condition by melting, cutting, tearing, scratching, crushing, breaking, punching, neutralizing, etc. (As an alternate, burial or deep water dumping may be used when coordinated with the DoD Demilitarization Program Office.) |
Controlled Inventory Item Code: | 7 | NON-SENSITIVE (SRC-N/A) - UNCLASSIFIED AA&E: OR ITEMS ASSIGNED A DEMILITARIZATION CODE OTHER THAN A, B, Q, OR P FOR WHICH ANOTHER CIIC IS INAPPROPRIATE. (NOTE: THE LOSS, THEFT, UNLAWFUL DISPOSITION, AND/OR RECOVERY OF AN ITEM WITH CIIC 7 WILL BE INVESTIGATED IN ACCORDANCE WITH DOD-4000-25-2-M AND DOD 7200.14-R, VOLUME 12, CHAPTER 7). |
Electro-static Discharge Susceptible: | A | No known Electrostatic Discharge (ESD) or Electromagnetic Interference (EMI) sensitivity |
Precious Metals Indicator Code: | A | Item does not contain precious metal |
Criticality Code: | X | The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. |
Automatic Data Processing Equipment: | 0 | Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9) |
Category | Code | Description |
---|---|---|
NMF Description | 061700 | ELEC APPLIANCES/INSTRUMENTS NOI |
Less than car load rating | ||
Less than truck load rating | J | 100.2 |
Water commodity Code | 72D | unknown |
Originating Activity Code | ZE | New Zealand ZF ZG |
Air Dimension Code | A | Shipment is not a consolidation and does not exceed 72 inches in any dimension. |
Air Commodity | H | Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc. |
Air Special Handling | Z | No special handling required. |
Special Handling Code | 9 | unknonwn |
HAZMAT | ||
Type of Cargo | Z | No special type of cargo code applicable |
Management | NSN 6625-01-516-5522
Category | Code | Description |
---|---|---|
Price Validation | E | The current standard price is an estimated price.
|
Materiel Management Aggregation Code | SD | SU:SPACE LIFT RANGES |
Budget Code | Y | variousO & M:AF centrally procured equipment items. They are separate, primary end items (other than the weapon system itself) needed by a user to perform an assigned mission. They are nonexpendable items (ERRCD NF or ND) which are not consumed in use, and they do not lose their original identity during periods of use by incorporation into, or attachment to another assembly. |
Source of Supply | FGZ | Ogden Air Logistics Center Hill AFB, UT 84056-5609 |
Agency | DF | Department of the Air Force |
Service Organization | L | Lead Service - 22 (Repairable) |
Reparability | U | AF Equipment Management System (AFEMS) |
Acquisition Advice Codes | C | SERVICE/AGENCY-MANAGED (Service/Agency use only.) # Issue, transfer, or shipment is not subject to specialized controls other than those imposed by individual Services supply policy. 1. The item is centrally managed, stocked, and issued. 2. Requisitions will be submitted in accordance with Service requisitioning procedures. |
Controlled Item Code | 7 | NON-SENSITIVE (SRC-N/A) - UNCLASSIFIED AA&E: OR ITEMS ASSIGNED A DEMILITARIZATION CODE OTHER THAN A, B, Q, OR P FOR WHICH ANOTHER CIIC IS INAPPROPRIATE. (NOTE: THE LOSS, THEFT, UNLAWFUL DISPOSITION, AND/OR RECOVERY OF AN ITEM WITH CIIC 7 WILL BE INVESTIGATED IN ACCORDANCE WITH DOD-4000-25-2-M AND DOD 7200.14-R, VOLUME 12, CHAPTER 7). |
Shelf Life Code | 0 | Nondeteriorative |
Purchasing | QTY UOM |
1 EA : Each |