Product Details | ELECTRICAL POWER CALIBRATOR

6625-01-494-6968 An item that determines by comparison the electrical power ratings of components such as attenuators, directional couplers, electrical power meters, insertion loss devices, signal generators, and the like.

Part Alternates: 5520ASC600, 5520A-SC600, 6625-01-494-6968, 01-494-6968, 6625014946968, 014946968

Instruments and Laboratory Equipment | Electrical and Electronic Properties Measuring and Testing Instruments

Supply Group (FSG) NSN Assign. NIIN
66 20 FEB 2002 01-494-6968

Demand History | NSN 6625-01-494-6968

Part Number Request Date QTY Origin
6625-01-494-6968 2008-03-91 1 US

Cross Reference | NSN 6625-01-494-6968

Part Number Cage Code Manufacturer
5520A-SC600 89536 FLUKE CORPORATION

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 6625-01-494-6968

Technical Data | NSN 6625-01-494-6968

Characteristic Specifications
CALIBRATION TYPE ANY ACCEPTABLE
AC VOLTAGE RATING 0.001 VOLTS MINIMUM AND 1.02 KILOVOLTS MAXIMUM
FREQUENCY RATING 10.0 HERTZ MINIMUM AND 500.0 KILOHERTZ MAXIMUM
DC VOLTAGE RATING 0.0 VOLTS MINIMUM AND 1.02 KILOVOLTS MAXIMUM
OVERALL LENGTH 18.600 INCHES NOMINAL
OVERALL WIDTH 17.000 INCHES NOMINAL
OVERALL HEIGHT 7.000 INCHES NOMINAL
SHAPE RECTANGULAR
III UNPACKAGED UNIT WEIGHT 49.000 POUNDS
III FUNCTIONAL DESCRIPTION SOURCES DIRECT VOLTAGE AND CURRENT ALTERNATING VOLTAGE AND CURRENT WITHMULTIPLE WAVEFORMS AND HARMONICS TWO SIMULTANEOUS VOLTAGE OUTPUTS OR VOLTAGEAND CURRENT TO SIMULATE DC AND AC POW ER WITH PHASE CONTROL, RISISTANCE, CAPACITANCE, THERMOCOUPLES AND RTD'S

Restrictions/Controls & Freight Information | NSN 6625-01-494-6968

Category Code Description
Hazardous Material Indicator CodePThere is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product
Demilitarization Code:ANon-Munitions List Item/ Non-Strategic List Item - Demilitarization not required.
Electro-static Discharge Susceptible:ANo known Electrostatic Discharge (ESD) or Electromagnetic Interference (EMI) sensitivity
Precious Metals Indicator Code:AItem does not contain precious metal
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Automatic Data Processing Equipment:0Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)
Category Code Description
No Freight Information