Product Details | SIGNAL GENERATOR

6625-01-488-7428 An instrument which produces a continuous audio and/or radio frequency voltage, and which is designed for test purposes only. It may provide an output at one or more fixed frequencies or be continuously variable over one or more bands. The fixed frequency type is distinguished from CALIBRATOR, FREQUENCY in that it is a voltage source and is not primarily intended for checking frequencies from other sources. Excludes GENERATOR, INTERFERENCE.

Part Alternates: 7011672355, 7011672-355, 6625-01-488-7428, 01-488-7428, 6625014887428, 014887428

Instruments and Laboratory Equipment | Electrical and Electronic Properties Measuring and Testing Instruments

Supply Group (FSG) NSN Assign. NIIN
66 31 AUG 2001 01-488-7428

Cross Reference | NSN 6625-01-488-7428

Part Number Cage Code Manufacturer
7011672-355 07187 HONEYWELL INTERNATIONAL INC. DBA HONEYWELL

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 6625-01-488-7428

Technical Data | NSN 6625-01-488-7428

Characteristic Specifications
SPECIAL FEATURES THE SG-805 IS A COMPONENT IN THE EDZ ELECTRONIC FLIGHT INSTRUMENT SYSTEM. THE SG-805 IS THE FOCAL POINT OF INFORMATION FLOW IN THE SYSTEM. THE SYMBOL GENERATOR'S MAJOR TASKS ARE TO CONVERT THE INFORMATION PRESENT AT ITS INPUTS TO VIDEO AND DEFLECTION FORMATS REQUIRED BY THE DISPLAY UNITS TO FORM THE ADI AND HIS DISPLAYS. THIS UNIT REPLACES THE -155 UNIT
III END ITEM IDENTIFICATION CHINOOK
III PART NAME ASSIGNED BY CONTROLLING AGENCY EFIS, SG-705 SYMBOL

Restrictions/Controls & Freight Information | NSN 6625-01-488-7428

Category Code Description
Hazardous Material Indicator CodePThere is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product
Demilitarization Code:DMunitions List Item or Commerce Control List Item. Demilitarization required. Total destruction of the item and components so as to preclude restoration or repair to a usable condition by melting, cutting, tearing, scratching, crushing, breaking, punching, neutralizing, etc. (As an alternate, burial or deep water dumping may be used when coordinated with the DoD Demilitarization Program Office.)
Electro-static Discharge Susceptible:ANo known Electrostatic Discharge (ESD) or Electromagnetic Interference (EMI) sensitivity
Precious Metals Indicator Code:AItem does not contain precious metal
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Automatic Data Processing Equipment:0Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)
Category Code Description