Product Details | SIGNAL GENERATOR

6625-01-437-5285 An instrument which produces a continuous audio and/or radio frequency voltage, and which is designed for test purposes only. It may provide an output at one or more fixed frequencies or be continuously variable over one or more bands. The fixed frequency type is distinguished from CALIBRATOR, FREQUENCY in that it is a voltage source and is not primarily intended for checking frequencies from other sources. Excludes GENERATOR, INTERFERENCE.

Part Alternates: 2410A, 6625-01-437-5285, 01-437-5285, 6625014375285, 014375285

Instruments and Laboratory Equipment | Electrical and Electronic Properties Measuring and Testing Instruments

Supply Group (FSG) NSN Assign. NIIN
66 17 OCT 1996 01-437-5285

Cross Reference | NSN 6625-01-437-5285

Part Number Cage Code Manufacturer
2410A 34280 WAVETEK RF PRODUCTS INC

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 6625-01-437-5285

Technical Data | NSN 6625-01-437-5285

Characteristic Specifications
RELATIONSHIP TO SIMILAR EQUIPMENT SIMILAR TO 6625-01-293-7227
OVERALL WIDTH 12.500 INCHES NOMINAL
FREQUENCY RANGE RATING +0.010/+1100.000 MEGAHERTZ
OVERALL LENGTH 21.000 INCHES NOMINAL
OVERALL HEIGHT 5.200 INCHES NOMINAL
FUNCTIONAL DESCRIPTION T6,L4,SH1,AH1,RL1,DC1,DT1,E2,SR1,TE0,LE0,PP0,C0
SPECIAL FEATURES IEEE-488 INTERFACE STANDARD;EXTENSIVE SELF DIAGNOSTICS AND AUTOCAL

Restrictions/Controls & Freight Information | NSN 6625-01-437-5285

Category Code Description
Hazardous Material Indicator CodePThere is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product
Demilitarization Code:BMunitions List Item - Mutilation (MUT) to the point of scrap required. (Formerly: Demilitarization not required. Trade Security Controls (TSCs) required at disposition.)
Precious Metals Indicator Code:AItem does not contain precious metal
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Automatic Data Processing Equipment:0Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)
Category Code Description
No Freight Information