Product Details | SIGNAL GENERATOR

6625-01-407-6019 An instrument which produces a continuous audio and/or radio frequency voltage, and which is designed for test purposes only. It may provide an output at one or more fixed frequencies or be continuously variable over one or more bands. The fixed frequency type is distinguished from CALIBRATOR, FREQUENCY in that it is a voltage source and is not primarily intended for checking frequencies from other sources. Excludes GENERATOR, INTERFERENCE.

Part Alternates: TSG 130A, TSG130A, 6625-01-407-6019, 01-407-6019, 6625014076019, 014076019

Instruments and Laboratory Equipment | Electrical and Electronic Properties Measuring and Testing Instruments

Supply Group (FSG) NSN Assign. NIIN
66 31 JAN 1995 01-407-6019

Cross Reference | NSN 6625-01-407-6019

Part Number Cage Code Manufacturer
TSG 130A 80009 TEKTRONIX, INC. DBA TEKTRONIX

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 6625-01-407-6019

Technical Data | NSN 6625-01-407-6019

Characteristic Specifications
FREQUENCY RANGE RATING 48.000 TO 62.000 HERTZ
OUTPUT IMPEDANCE RATING 75.0 OHMS NOMINAL
CURRENT TYPE AC
VOLTAGE RATING 90.0 VOLTS MINIMUM AND 250.0 VOLTS MAXIMUM
OVERALL LENGTH 15.000 INCHES NOMINAL
OVERALL WIDTH 8.100 INCHES NOMINAL
OVERALL HEIGHT 1.710 INCHES NOMINAL
MOUNTING TYPE RACK

Restrictions/Controls & Freight Information | NSN 6625-01-407-6019

Category Code Description
Hazardous Material Indicator CodePThere is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product
Demilitarization Code:ANon-Munitions List Item/ Non-Strategic List Item - Demilitarization not required.
Electro-static Discharge Susceptible:ANo known Electrostatic Discharge (ESD) or Electromagnetic Interference (EMI) sensitivity
Precious Metals Indicator Code:AItem does not contain precious metal
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Automatic Data Processing Equipment:0Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)
Category Code Description
No Freight Information