Product Details | FREQUENCY STANDARD

6625-01-391-9080 An item that can generate a fundamental frequency with a high degree of accuracy. Harmonics of this fundamental are then used as a reference point for checking throughout the radio spectrum. The standard may be stable crystal oscillator, noncrystal oscillator, tuning fork, atomic beam, molecular beam, gas cell, quantum mechanical resonator, or the like.

Part Alternates: FTS 4065, FTS4065, 4065, 6625-01-391-9080, 01-391-9080, 6625013919080, 013919080

Instruments and Laboratory Equipment | Electrical and Electronic Properties Measuring and Testing Instruments

Supply Group (FSG) NSN Assign. NIIN
66 18 JUN 1994 01-391-9080

Cross Reference | NSN 6625-01-391-9080

Part Number Cage Code Manufacturer
4065 56219 MICROSEMI FREQUENCY AND TIME CORPORATION
FTS 4065 56219 MICROSEMI FREQUENCY AND TIME CORPORATION

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 6625-01-391-9080

Technical Data | NSN 6625-01-391-9080

Characteristic Specifications
UNIT TYPE STANDARD
FREQUENCY RANGE RATING 1.000 TO 10.000 MEGAHERTZ
INDIVIDUAL PLUG-IN UNIT FREQUENCY NOT RATED
INDIVIDUAL CHANNEL FREQUENCY 1.0 MEGAHERTZ NOMINAL AND 5.0 MEGAHERTZ NOMINAL AND 10.0 MEGAHERTZ NOMINAL
AC VOLTAGE RATING 115.0 VOLTS NOMINAL AND 230.0 VOLTS NOMINAL
FREQUENCY RATING 47.0 HERTZ MINIMUM AND 400.0 HERTZ MAXIMUM
PHASE SINGLE
OVERALL WIDTH 19.000 INCHES NOMINAL
OVERALL HEIGHT 5.200 INCHES NOMINAL
OVERALL DEPTH 21.000 INCHES NOMINAL
MOUNTING METHOD RACK
RECORDING DEVICE ACCOMMODATION NOT PROVIDED
SPECIAL FEATURES CESIUM TIME AND FREQUENCY STANDARD: PROVIDES OUTPUT FREQUENCIES OF 1, 5, AND 10 MHZ AND A 1PPS SIGNAL WHICH CAN BE DELAYED IN 100 NANOSECOND STEPS
III END ITEM IDENTIFICATION PRECISION MEASUREMENT EQUIPMANT LABS
III UNPACKAGED UNIT WEIGHT 63.000 POUNDS
MANUFACTURERS CODE 56219
DESIGN CONTROL REFERENCE FTS 4065

Restrictions/Controls & Freight Information | NSN 6625-01-391-9080

Category Code Description
Shelf-Life Code:0Nondeteriorative
Hazardous Material Indicator CodePThere is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product
Demilitarization Code:QStrategic List Item (SLI). Demilitarization not required. SLI are non-MLI(Munitions List Items) controlled by the U.S. Dept. of Commerce through the Export Administration Regulations (EAR) and indicated on the Commerce Control List (CCL). Each CCL entry is preceded by a four-digit Export Control Commerce Control List Item (CCLI) – MUT to the point of scrap required outside the United States. Inside the United States, MUT is required when the DEMIL integrity code (IC) is “3” and MUT is not required when the DEMIL IC is “6.”
Controlled Inventory Item Code:UUNCLASSIFIED
Precious Metals Indicator Code:AItem does not contain precious metal
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Automatic Data Processing Equipment:0Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)
Category Code Description
NMF Description 061700 ELEC APPLIANCES/INSTRUMENTS NOI
Less than car load rating P 77.5
Less than truck load rating J 100.2
Water commodity Code 738 unknown
Originating Activity Code TK HQ AFMC/GLSC 401 SCM/GUMB
Wright-Patterson AFB, OH 45433-5000
Air Dimension Code A Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Air Commodity H Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
Air Special Handling Z No special handling required.
Special Handling Code 9 unknonwn
HAZMAT
Type of Cargo 3 Electrostatic Sensitive Device (ESD), subject to damage caused by electrostatic discharge. (See DoD 4500.32-R, Volume 1, Appendix A, Section I for additional information on ESD devices).

Management | NSN 6625-01-391-9080

Category Code Description
Materiel Category and Inventory ManagerG Communications and Electronics Equipment, Electronics Materiel
Appropriation and Budget ActivityP Communications and Electronics Equipment (except Safeguard)
Management Inventory Segment1 REPARABLE ITEMS (Exclusive of Insurance and Provisioning Items.) This code will be used to identify serviceable or unserviceable items of a durable nature which when unserviceable normally can be repaired economically by depots or lower echelons of maintenance.
Specific Group/Generic Code0 Medical Materiel
Weapons Systems/End Item or Homogeneous Group00DLA/GSA-Managed Items that cannot be identified to a specific Army Weapons Systems/End Item
Accounting Requirements CodeN Nonexpendable item. An item of Army property coded with an ARC of?N?in the AMDF. Nonexpendable items require property book accountability after issue from the stock record account. Commercial and fabricated items similar to items coded ?N? in the AMDF are considered nonexpendable items.
Source of SupplyB16US Army Communications-Electronics
Command and Fort Monmouth
Fort Monmouth, NJ 07703-5016
AgencyDADepartment of the Army
Service OrganizationAU.S. Army
Acquisition Advice CodesVTERMINAL ITEM # Identifies items in stock, but future procurement is not authorized. Requisitions may continue to be submitted until stocks are exhausted. Preferred item National Stock Number is normally provided by application of the phrase: When Exhausted Use (NSN). Requisitions will be submitted in accordance with IMM/Service requisitioning procedures as applicable.
Controlled Item CodeUUNCLASSIFIED
Shelf Life Code0Nondeteriorative
Purchasing QTY
UOM
1
EA : Each
Category Code Description
Price ValidationE The current standard price is an estimated price.
  • Estimated Price challenges are allowed, but follow procedures in para 60.b. (3) of section L of this manual.
  • This code will be changed to a P code upon notification of a contract price or this code will be changed to an updated code upon determination of a valid price.
Materiel Management Aggregation CodeRHTG:AUTO TEST EQUIPMENT/AUTO TEST SYSTEMS (ATE/ATS) (FSC RESIDUAL MMAC)
Budget CodeY variousO & M:AF centrally procured equipment items. They are separate, primary end items (other than the weapon system itself) needed by a user to perform an assigned mission. They are nonexpendable items (ERRCD NF or ND) which are not consumed in use, and they do not lose their original identity during periods of use by incorporation into, or attachment to another assembly.
Source of SupplyFLZWarner Robins Air Logistics Center
Robins AFB, GA 31098-5609
AgencyDFDepartment of the Air Force
Service OrganizationLLead Service - 22 (Repairable)
ReparabilitySAF Equipment Management System (AFEMS)
Acquisition Advice CodesVTERMINAL ITEM # Identifies items in stock, but future procurement is not authorized. Requisitions may continue to be submitted until stocks are exhausted. Preferred item National Stock Number is normally provided by application of the phrase: When Exhausted Use (NSN). Requisitions will be submitted in accordance with IMM/Service requisitioning procedures as applicable.
Controlled Item CodeUUNCLASSIFIED
Shelf Life Code0Nondeteriorative
Purchasing QTY
UOM
1
EA : Each