Product Details | TEST ADAPTER

6625-01-353-7182 An adapter which provides facilities for electrically connecting an item to be tested and a piece of test equipment. Do not use for interconnecting cables. Includes plug-in electronic component socket adapters which provide terminations for dynamic testing while an electronic component is inserted. See also COUPLER, TEST SET.20649200058Aircraft Maintenance and Repair Shop Specialized Equipment49310062Fire Control Maintenance and Repair Shop Specialized Equipment49330057Weapons Maintenance and Repair Shop Specialized Equipment49350070Guided Missile Maintenance, Repair, and Checkout Specialized Equipment49400063Miscellaneous Maintenance and Repair Shop Specialized Equipment66250070Electrical and Electronic Properties Measuring and Testing Instruments

Part Alternates: 8508358001, 85-08358-001, 6625-01-353-7182, 01-353-7182, 6625013537182, 013537182

Instruments and Laboratory Equipment | Electrical and Electronic Properties Measuring and Testing Instruments

Supply Group (FSG) NSN Assign. NIIN
66 14 FEB 1992 01-353-7182

Cross Reference | NSN 6625-01-353-7182

Part Number Cage Code Manufacturer
85-08358-001 33875 RAYTHEON E-SYSTEMS INC

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 6625-01-353-7182

Technical Data | NSN 6625-01-353-7182

Characteristic Specifications
TEST ITEM CONNECTION METHOD CONNECTOR AND JACK
FREQUENCY RANGE NOT RATED
DC VOLTAGE RATING 5.0 VOLTS NOMINAL
III END ITEM IDENTIFICATION MULTI-SERVICE ADAPTER SECURITY MODULE 5998-01-3363643; CCA 5998-01-336-8654,AND CCA 5998-01-336-7185
III SUPPLEMENTARY FEATURES REQUIRES MLP-1 CABLE P/N 85-08365-8-001,CODEC CABLE P/N 85-08367-001,AND MLP-1 ADAPTER P/N 85-08360-001
III FUNCTIONAL DESCRIPTION PROVIDES TRANSITION FROM FIBER OPTIC LOGIC TO TTL AND/OR TTL TO FIBER OPTIC LOGIC
MANUFACTURERS CODE 33875
DESIGN CONTROL REFERENCE 85-08358-001

Restrictions/Controls & Freight Information | NSN 6625-01-353-7182

Category Code Description
Hazardous Material Indicator CodePThere is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product
Demilitarization Code:DMunitions List Item or Commerce Control List Item. Demilitarization required. Total destruction of the item and components so as to preclude restoration or repair to a usable condition by melting, cutting, tearing, scratching, crushing, breaking, punching, neutralizing, etc. (As an alternate, burial or deep water dumping may be used when coordinated with the DoD Demilitarization Program Office.)
Precious Metals Indicator Code:AItem does not contain precious metal
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Automatic Data Processing Equipment:0Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)
Category Code Description
NMF Description 061700 ELEC APPLIANCES/INSTRUMENTS NOI
Less than car load rating M 85
Less than truck load rating W Rating Variable
Water commodity Code 658 unknown
Originating Activity Code TA Sacramento Air Logistics Center
McClellan AFB, CA 95652-5609
Air Dimension Code A Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Air Commodity
Air Special Handling Z No special handling required.
Special Handling Code Z unknonwn
HAZMAT
Type of Cargo Z No special type of cargo code applicable