NSN 6625-01-304-8034 8720A010, 8720A-010, 01-304-8034
Product Details | NETWORK ANALYZER
6625-01-304-8034 An instrument that measures transfer function and/or impedance function, or both, of linear networks through sine wave testing.
Part Alternates: 8720A010, 8720A-010, 6625-01-304-8034, 01-304-8034, 6625013048034, 013048034
Instruments and Laboratory Equipment | Electrical and Electronic Properties Measuring and Testing Instruments
Supply Group (FSG) | NSN Assign. | NIIN | Item Name Code (INC) |
---|---|---|---|
66 | 27 JUL 1989 | 01-304-8034 | 46562 ( ANALYZER, NETWORK ) |
Cross Reference | NSN 6625-01-304-8034
Part Number | Cage Code | Manufacturer |
---|---|---|
8720A-010 | 28480 | HEWLETT-PACKARD COMPANY DBA HEWLETT-PACKARD CO. OR HP |
Request a Quote
What Our Customers Say
Compare
NSNs for Compare ( up to 4 ): Add 6625-01-304-8034
Related Products | NSN 6625-01-304-8034
Technical Data | NSN 6625-01-304-8034
Characteristic | Specifications |
---|---|
INDICATOR TYPE | CATHODE RAY TUBE |
ELECTRICAL POWER SOURCE RELATIONSHIP | OPERATING |
SPECIAL FEATURES | OPT 010 IS TIME DOMAIN ANALYSIS; DYNAMIC RANGE FOR TRANSMISSION MEASUREMENTS: 70 DB FOR 0.13 TO 0.5 GHZ, 80 DB FOR 0.5 TO 2.0 GHZ, 85 DB FOR 2.0 TO 8.0 GHZ, 85 DB FOR 8.0 TO 20.0 GHZ; SOURCE FREQUENCY CHARACTERISTICS: RANGE IS 130.0 MHZ TO 20.0 GHZ, RESOLUTION IS 100 KHZ (1HZ W/OPT 001), STABILITY IS TYPICALLY PORM 7.5 PPM AT 0 TO 55 DEG. C, TYPICALLY PORM 3.0 PPM/YEAR, ACCURACY IS 10.0 PPM AT 25 DEG PORM 3 DEG. C; OUTPUT CHARACTERISTICS: POWER RANGE IS MINUS 10 TO MINUS 65 DBM IN 5DB STEPS, POWER LEVEL IS MINUS 10 DBM PORM 3DB, HARMONICS IS < MINUS 15 DBC AT MINUS 10 DBM (TYPICAL); TEST PORTS: CONNECTOR TYPE IS 3.5 MM MALE, IMPEDANCE IS 50 OHMS NOMINAL |
III FUNCTIONAL DESCRIPTION | PROVIDES VECTOR NETWORK MEASUREMENTS IN A COMPACT AND FULLY INTEGRATED NETWORK ANALYZER |
III REFERENCE DATA AND LITERATURE | HP 1989 PRODUCT CATALOG |
Restrictions/Controls & Freight Information | NSN 6625-01-304-8034
Category | Code | Description |
---|---|---|
Hazardous Material Indicator Code | P | There is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product |
Demilitarization Code: | A | Non-Munitions List Item/ Non-Strategic List Item - Demilitarization not required. |
Precious Metals Indicator Code: | A | Item does not contain precious metal |
Criticality Code: | X | The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. |
Automatic Data Processing Equipment: | 0 | Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9) |
Category | Code | Description |
---|---|---|
No Freight Information |