Product Details | INSTRUMENT SHUNT

6625-01-301-9831 A fixed precision resistor consisting of a bar or bars of metal specifically designed for use in parallel with a basic direct current instrument to permit determination of current values exceeding the actual range of the instrument itself.

Part Alternates: 840680, 8406-80, 6625-01-301-9831, 01-301-9831, 6625013019831, 013019831

Instruments and Laboratory Equipment | Electrical and Electronic Properties Measuring and Testing Instruments

Supply Group (FSG) NSN Assign. NIIN
66 07 JUN 1989 01-301-9831

Cross Reference | NSN 6625-01-301-9831

Part Number Cage Code Manufacturer
8406-80 91812 JANCO CORPORATION DBA ESTERLINE MASON

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 6625-01-301-9831

Technical Data | NSN 6625-01-301-9831

Characteristic Specifications
TERMINAL LOCATION ONE SIDE
UNTHREADED MOUNTING HOLE DIAMETER 0.205 INCHES NOMINAL
SPECIAL TEST FEATURES CONFORMS TO MIL-S-61B
TERMINAL TYPE AND QUANTITY 2 SCREW
OVERALL HEIGHT 1.562 INCHES MINIMUM AND 1.688 INCHES MAXIMUM
OVERALL LENGTH 1.938 INCHES MINIMUM AND 2.062 INCHES MAXIMUM
OVERALL WIDTH 1.188 INCHES MINIMUM AND 1.312 INCHES MAXIMUM
SUPPLEMENTARY FEATURES 0.5 PCT ACCURACY
MOUNTING METHOD UNTHREADED HOLE
SPECIAL FEATURES ALKYD BASE
USAGE DESIGN EXTERNAL
MOUNTING PROVISION QUANTITY 2
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH 0.865 INCHES MINIMUM AND 0.885 INCHES MAXIMUM
FURNISHED ITEMS AND QUANTITY NUT 4; WASHER 4
CURRENT RATING AND TYPE 80.0 AMPERES NOMINAL DC
SPECIAL MARKINGS 100 MV,80 AMPS
ELEMENT MATERIAL MANGANESE
VOLTAGE DROP IN MILLIVOLTS 100.0 NOMINAL

Restrictions/Controls & Freight Information | NSN 6625-01-301-9831

Category Code Description
Hazardous Material Indicator CodePThere is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product
Demilitarization Code:ANon-Munitions List Item/ Non-Strategic List Item - Demilitarization not required.
Precious Metals Indicator Code:AItem does not contain precious metal
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Automatic Data Processing Equipment:0Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)
Category Code Description
No Freight Information