NSN 6625-01-262-0466 VENCAT30, 01-262-0466, 012620466
Product Details | ELECTRONIC TEST DIGITAL DATA ANALYZER
6625-01-262-0466 An instrument designed to receive and process digital signals from associated components in order to perform analysis of logic states, timing functions and microprocessor control. May include a display screen and/or triggering capabilities.
Part Alternates: VENCAT30, 6625-01-262-0466, 01-262-0466, 6625012620466, 012620466
Instruments and Laboratory Equipment | Electrical and Electronic Properties Measuring and Testing Instruments
Supply Group (FSG) | NSN Assign. | NIIN | Item Name Code (INC) |
---|---|---|---|
66 | 21 AUG 1987 | 01-262-0466 | 46820 ( ANALYZER, DIGITAL DATA, ELECTRONIC TEST ) |
Request a Quote
What Our Customers Say
Compare
NSNs for Compare ( up to 4 ): Add 6625-01-262-0466
Related Products | NSN 6625-01-262-0466
Technical Data | NSN 6625-01-262-0466
Characteristic | Specifications |
---|---|
ELECTRICAL POWER SOURCE RELATIONSHIP | ALTERNATE OPERATING |
AC VOLTAGE RATING | 230.0 VOLTS NOMINAL |
FREQUENCY RATING | 50.0 HERTZ NOMINAL |
PHASE | SINGLE |
OVERALL WIDTH | 10.000 INCHES NOMINAL |
OVERALL HEIGHT | 3.500 INCHES NOMINAL |
OVERALL LENGTH | 14.000 INCHES NOMINAL |
SPECIAL FEATURES | ALSO INPUT POWER -48 VDC; FREQUENCY RESPONSE 300 TO 3400 HZ; INCLUDES POWER CORD, OPERATING MANUAL AND RUBBER MOUNTING FEET |
III SUPPLEMENTARY FEATURES | MANUFACTURERS NAME: CHANNEL ACCESS TEST SET |
III FUNCTIONAL DESCRIPTION | A T-CARRIER CHANNEL SELECTOR TEST SET CAPABLE OF BREAKING OUT THE RECEIVE AND TRANSMIT SEGMENTS OF A CCITT DS-30 PCM DATA STREAM INTO INDIVIDUAL CHANNELS, AND ANALYZE THE SIGNALS TO DETERMINE IF THE DATA STREAM IS CORRECT |
MANUFACTURERS CODE | 55203 |
DESIGN CONTROL REFERENCE | VENCAT30 |
Restrictions/Controls & Freight Information | NSN 6625-01-262-0466
Category | Code | Description |
---|---|---|
Shelf-Life Code: | 0 | Nondeteriorative |
Hazardous Material Indicator Code | P | There is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product |
Demilitarization Code: | Q | Strategic List Item (SLI). Demilitarization not required. SLI are non-MLI(Munitions List Items) controlled by the U.S. Dept. of Commerce through the Export Administration Regulations (EAR) and indicated on the Commerce Control List (CCL). Each CCL entry is preceded by a four-digit Export Control Commerce Control List Item (CCLI) – MUT to the point of scrap required outside the United States. Inside the United States, MUT is required when the DEMIL integrity code (IC) is “3” and MUT is not required when the DEMIL IC is “6.” |
Controlled Inventory Item Code: | U | UNCLASSIFIED |
Precious Metals Indicator Code: | A | Item does not contain precious metal |
Criticality Code: | X | The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. |
Automatic Data Processing Equipment: | 0 | Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9) |
Category | Code | Description |
---|---|---|
NMF Description | 061700 | ELEC APPLIANCES/INSTRUMENTS NOI |
Less than car load rating | P | 77.5 |
Less than truck load rating | J | 100.2 |
Water commodity Code | 738 | unknown |
Originating Activity Code | SE | San Antonio Air Logistics Center Kelly AFB, TX 78241-5000 |
Air Dimension Code | A | Shipment is not a consolidation and does not exceed 72 inches in any dimension. |
Air Commodity | H | Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc. |
Air Special Handling | Q | Extremely fragile items including delicate instruments. |
Special Handling Code | 9 | unknonwn |
HAZMAT | ||
Type of Cargo | 3 | Electrostatic Sensitive Device (ESD), subject to damage caused by electrostatic discharge. (See DoD 4500.32-R, Volume 1, Appendix A, Section I for additional information on ESD devices). |
Management | NSN 6625-01-262-0466
Category | Code | Description |
---|---|---|
Fund Code | LP | Items initially authorized for local purchase. |
Price Validation | N | The current standard price in Catalog Management Data (CMD) has not analyzed or coded for LP/LM.
|
Materiel Management Aggregation Code | RH | TG:AUTO TEST EQUIPMENT/AUTO TEST SYSTEMS (ATE/ATS) (FSC RESIDUAL MMAC) |
Source of Supply | FLZ | Warner Robins Air Logistics Center Robins AFB, GA 31098-5609 |
Agency | DF | Department of the Air Force |
Service Organization | L | Lead Service - 22 (Repairable) |
Reparability | U | AF Equipment Management System (AFEMS) |
Acquisition Advice Codes | X | SEMIACTIVE ITEM-NO REPLACEMENT (NON-STOCKED ITEMS) A potentially inactive NSN which must be retained in the supply system as an item of supply because (1) stocks of the item are on hand or in use below the wholesale level and (2) the NSN is cited in equipment authorization documents TO & E, TA, TM, etc., or in-use assets are being reported. 1. Items are authorized for central procurement but not authorized for stockage at wholesale level. 2. Requisitions for in-use replacement will be authorized in accordance with individual Military Service directives. 3. Requisitions may be submitted as requirements generate. Repetitive demands may dictate an AAC change to permit wholesale stockage. |
Controlled Item Code | U | UNCLASSIFIED |
Shelf Life Code | 0 | Nondeteriorative |
Purchasing | QTY UOM |
1 EA : Each |