NSN 6625-01-187-3334 G1714361, G171436-1, G2278791
Product Details | RADIO FREQUENCY POWER TEST SET
6625-01-187-3334 A test set primarily designed for use in making examinations of the power output of radio frequency oscillators and radio and radar transmitters. See also TEST SET, ELECTRICAL POWER; and WATTMETER.20211900057Specialized Test and Handling Equipment, Nuclear Ordnance66250070Electrical and Electronic Properties Measuring and Testing Instruments
Part Alternates: G1714361, G171436-1, G2278791, G227879-1, 6625-01-187-3334, 01-187-3334, 6625011873334, 011873334
Instruments and Laboratory Equipment | Electrical and Electronic Properties Measuring and Testing Instruments
Supply Group (FSG) | NSN Assign. | NIIN | Item Name Code (INC) |
---|---|---|---|
66 | 21 AUG 1984 | 01-187-3334 | 21191 ( TEST SET, RADIO FREQUENCY POWER ) |
Request a Quote
What Our Customers Say
Compare
NSNs for Compare ( up to 4 ): Add 6625-01-187-3334
Related Products | NSN 6625-01-187-3334
Technical Data | NSN 6625-01-187-3334
Characteristic | Specifications |
---|---|
INPUT FREQUENCY RANGE | 60.000 TO 400.000 HERTZ |
RADIO FREQUENCY INPUT POWER RATING | 3.0 WATTS NOMINAL |
MEASUREMENT UNIT | AVERAGE POWER AND PEAK POWER |
SCALE UNIT OF MEASURE INSCRIPTION | ALTERNATING CURRENT AND DIRECT CURRENT |
AC VOLTAGE RATING | 115.0 VOLTS NOMINAL |
PHASE | SINGLE |
DC VOLTAGE RATING | 300.0 VOLTS NOMINAL |
INCLOSURE FEATURE | MULTIPLE ITEM W/CARRYING CASE |
LENGTH | 19.000 INCHES NOMINAL |
HEIGHT | 18.000 INCHES NOMINAL |
DEPTH | 12.000 INCHES NOMINAL |
FURNISHED ITEMS | TRANSFORMER;CONVERTER;FAINT AND INVERTER MODULES |
JOINT ELECTRONICS TYPE DESIGNATION SYSTEM ITEM NAME | RADIO TERMINAL SET |
JOINT ELECTRONICS TYPE DESIGNATION SYSTEM ITEM TYPE NUMBER | AN/TRC-170 |
MANUFACTURERS CODE | 3B150 |
DESIGN CONTROL REFERENCE | G171436-1 |
Restrictions/Controls & Freight Information | NSN 6625-01-187-3334
Category | Code | Description |
---|---|---|
Shelf-Life Code: | 0 | Nondeteriorative |
Hazardous Material Indicator Code | P | There is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product |
Demilitarization Code: | A | Non-Munitions List Item/ Non-Strategic List Item - Demilitarization not required. |
Controlled Inventory Item Code: | U | UNCLASSIFIED |
Precious Metals Indicator Code: | A | Item does not contain precious metal |
Criticality Code: | X | The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. |
Automatic Data Processing Equipment: | 0 | Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9) |
Category | Code | Description |
---|---|---|
NMF Description | 061700 | ELEC APPLIANCES/INSTRUMENTS NOI |
Less than car load rating | P | 77.5 |
Less than truck load rating | W | Rating Variable |
Water commodity Code | 72D | unknown |
Originating Activity Code | TA | Sacramento Air Logistics Center McClellan AFB, CA 95652-5609 |
Air Dimension Code | A | Shipment is not a consolidation and does not exceed 72 inches in any dimension. |
Air Commodity | H | Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc. |
Air Special Handling | Z | No special handling required. |
Special Handling Code | Z | unknonwn |
HAZMAT | ||
Type of Cargo | Z | No special type of cargo code applicable |