NSN 6625-01-180-5865 2000023-36, 548A050608W10, 548A-05-06-08-W10
Product Details | DIGITAL READOUT ELECTRONIC COUNTER
6625-01-180-5865 An instrument used to count the frequency of recurrent electronic events and display the count on the panel of the instrument in numeric form. May also include facilities for a readout printed on tape. May include facilities for a very accurate output which can be used as a secondary transfer standard. It can be used to measure frequency, period, time interval, phase angle, frequency ratio, and for multiple period averaging. See also COUNTER, ELECTRONIC, DIGITAL and INDICATOR, DIGITAL DISPLAY.
Part Alternates: 2000023-36, 548A050608W10, 548A-05-06-08-W10, 548AW36, 548A-W36, 6625-01-180-5865, 01-180-5865, 6625011805865, 200002336, 011805865
Instruments and Laboratory Equipment | Electrical and Electronic Properties Measuring and Testing Instruments
Supply Group (FSG) | NSN Assign. | NIIN | Item Name Code (INC) |
---|---|---|---|
66 | 30 MAY 1984 | 01-180-5865 | 26835 ( COUNTER, ELECTRONIC, DIGITAL READOUT ) |
Request a Quote
What Our Customers Say
Compare
Related Products | NSN 6625-01-180-5865
Technical Data | NSN 6625-01-180-5865
Characteristic | Specifications |
---|---|
MEASUREMENT TYPE | FREQUENCY AND POWER |
FREQUENCY RANGE | 0.00000001 TO 110.00000000 GIGAHERTZ OVERALL |
ACCURACY RATING | PORM 1 COUNT PORM TIME BASE ERROR |
INTERNAL CALIBRATION FEATURE | INCLUDED |
DISPLAY TYPE | NUMERIC READOUT TUBE |
DISPLAY DIGIT QUANTITY | 12 |
DISPLAY UNITS INDICATOR | INCLUDED |
DISPLAY POSITIONED DECIMAL POINT | PROVIDED |
SOLID STATE FEATURE | INCLUDED |
PLUG-IN UNITS PROVISION | NOT INCLUDED |
MANUFACTURERS CODE | 34257 |
DESIGN CONTROL REFERENCE | 548A-W36 |
Restrictions/Controls & Freight Information | NSN 6625-01-180-5865
Category | Code | Description |
---|---|---|
Shelf-Life Code: | 0 | Nondeteriorative |
Hazardous Material Indicator Code | P | There is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product |
Demilitarization Code: | A | Non-Munitions List Item/ Non-Strategic List Item - Demilitarization not required. |
Controlled Inventory Item Code: | U | UNCLASSIFIED |
Electro-static Discharge Susceptible: | A | No known Electrostatic Discharge (ESD) or Electromagnetic Interference (EMI) sensitivity |
Precious Metals Indicator Code: | A | Item does not contain precious metal |
Criticality Code: | X | The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. |
Automatic Data Processing Equipment: | 0 | Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9) |
Category | Code | Description |
---|---|---|
NMF Description | 061700 | ELEC APPLIANCES/INSTRUMENTS NOI |
Less than car load rating | M | 85 |
Less than truck load rating | J | 100.2 |
Water commodity Code | 738 | unknown |
Originating Activity Code | SE | San Antonio Air Logistics Center Kelly AFB, TX 78241-5000 |
Air Dimension Code | A | Shipment is not a consolidation and does not exceed 72 inches in any dimension. |
Air Commodity | H | Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc. |
Air Special Handling | Z | No special handling required. |
Special Handling Code | 9 | unknonwn |
HAZMAT | ||
Type of Cargo | 3 | Electrostatic Sensitive Device (ESD), subject to damage caused by electrostatic discharge. (See DoD 4500.32-R, Volume 1, Appendix A, Section I for additional information on ESD devices). |
Management | NSN 6625-01-180-5865
Category | Code | Description |
---|---|---|
Materiel Management Aggregation Code | RH | TG:AUTO TEST EQUIPMENT/AUTO TEST SYSTEMS (ATE/ATS) (FSC RESIDUAL MMAC) |
Price Validation | X | The current standard price has been validated and the previous price was erroneous.
|
Budget Code | Y | variousO & M:AF centrally procured equipment items. They are separate, primary end items (other than the weapon system itself) needed by a user to perform an assigned mission. They are nonexpendable items (ERRCD NF or ND) which are not consumed in use, and they do not lose their original identity during periods of use by incorporation into, or attachment to another assembly. |
Source of Supply | FLZ | Warner Robins Air Logistics Center Robins AFB, GA 31098-5609 |
Agency | DF | Department of the Air Force |
Service Organization | L | Lead Service - 22 (Repairable) |
Reparability | S | AF Equipment Management System (AFEMS) |
Acquisition Advice Codes | V | TERMINAL ITEM # Identifies items in stock, but future procurement is not authorized. Requisitions may continue to be submitted until stocks are exhausted. Preferred item National Stock Number is normally provided by application of the phrase: When Exhausted Use (NSN). Requisitions will be submitted in accordance with IMM/Service requisitioning procedures as applicable. |
Controlled Item Code | U | UNCLASSIFIED |
Shelf Life Code | 0 | Nondeteriorative |
Purchasing | QTY UOM |
1 EA : Each |