Product Details | SWEEP GENERATOR

6625-01-176-8286 An electronic device which applies voltage or current to the deflection elements in a cathode ray tube in a way to make the deflection for the electron beam a known function of time or other data base, against which other periodically occurring electrical phenomena may be examined, compared, or measured. It is often referred to as a timing axis oscillator.20258950037Miscellaneous Communication Equipment66250070Electrical and Electronic Properties Measuring and Testing Instruments

Part Alternates: 121A, 6625-01-176-8286, 01-176-8286, 6625011768286, 011768286

Instruments and Laboratory Equipment | Electrical and Electronic Properties Measuring and Testing Instruments

Supply Group (FSG) NSN Assign. NIIN
66 17 APR 1984 01-176-8286

Drawings & Photos | NSN 6625-01-176-8286


Cross Reference | NSN 6625-01-176-8286

Part Number Cage Code Manufacturer
121A 34511 FLUKE BIOMEDICAL CORPORATION

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 6625-01-176-8286

Technical Data | NSN 6625-01-176-8286

Characteristic Specifications
CIRCUIT CONSTRUCTION TYPE SOLID STATE
FREQUENCY PER CHANNEL 0.02 HERTZ MINIMUM OUTPUT CHANNEL AND 2.2 MEGAHERTZ MAXIMUM OUTPUT CHANNEL
IMPEDANCE RATING PER CHANNEL 50.000 OHMS OUTPUT CHANNEL
OUTPUT WAVE SHAPE PULSE, SWEEP AND SAWTOOTH AND SQUARE AND SQUARE
EXTERNAL AC OPERATING VOLTAGE IN VOLTS 117.0 MINIMUM SINGLE VOLTAGE AND 230.0 MAXIMUM SINGLE VOLTAGE
OPERATING AC FREQUENCY IN HERTZ 50.0 MINIMUM SINGLE VOLTAGE AND 400.0 MAXIMUM SINGLE VOLTAGE
PHASE SINGLE
INCLOSURE TYPE ENCASED
INSTALLATION DESIGN TOP OF CABINET/COUNTER
BASIC SHAPE STYLE 1 RECTANGULAR OR SQUARE
OVERALL LENGTH 11.484 INCHES NOMINAL
OVERALL HEIGHT 2.847 INCHES NOMINAL
OVERALL WIDTH 8.424 INCHES NOMINAL

Restrictions/Controls & Freight Information | NSN 6625-01-176-8286

Category Code Description
Hazardous Material Indicator CodePThere is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product
Demilitarization Code:ANon-Munitions List Item/ Non-Strategic List Item - Demilitarization not required.
Precious Metals Indicator Code:UPrecious metal type is unknown
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Category Code Description
No Freight Information