NSN 6625-01-171-9783 HP1980B909, 1980B909, 54720D
Product Details | OSCILLOSCOPE
6625-01-171-9783 A test instrument which is designed to give visual indications on an LCD display or a cathode ray tube of instantaneous values and variations in electrical voltage. It can also be used to indicate any quantity which can be converted into terms of electrical potential. It may include an integral pulse generator, the output of which can be used to trigger an external component; be triggered by pulses from an external source, or it may utilize an LCD display or a special type of multigun cathode ray tube and circuitry which permits a trace(s) to be sustained and displayed indefinitely, and the trace(s) may be erased when desired. For items which are not separable and operable when detached from equipment of which they are a part (built into operational equipment), see INDICATOR (2) (as modified); MONITOR (as modified); and RECORDER (as modified). See also OSCILLOGRAPH.
Part Alternates: HP1980B909, 1980B909, 54720D, 6625-01-171-9783, 01-171-9783, 6625011719783, 011719783
Instruments and Laboratory Equipment | Electrical and Electronic Properties Measuring and Testing Instruments
Supply Group (FSG) | NSN Assign. | NIIN | Item Name Code (INC) |
---|---|---|---|
66 | 15 FEB 1984 | 01-171-9783 | 00357 ( OSCILLOSCOPE ) |
Cross Reference | NSN 6625-01-171-9783
Request a Quote
What Our Customers Say
Compare
Related Products | NSN 6625-01-171-9783
Technical Data | NSN 6625-01-171-9783
Characteristic | Specifications |
---|---|
SCREEN SIZE | 10 BY 12 CENTIMETERS |
SWEEP CIRCUITS | INCLUDED |
CURRENT TYPE | AC |
VOLTAGE RATING | 100.0 VOLTS MINIMUM AND 240.0 VOLTS MAXIMUM |
FREQUENCY RATING | 48.0 HERTZ MINIMUM AND 440.0 HERTZ MAXIMUM |
PHASE | SINGLE |
OVERALL LENGTH | 21.400 INCHES NOMINAL |
OVERALL WIDTH | 16.800 INCHES NOMINAL |
OVERALL HEIGHT | 5.600 INCHES NOMINAL |
Restrictions/Controls & Freight Information | NSN 6625-01-171-9783
Category | Code | Description |
---|---|---|
Hazardous Material Indicator Code | P | There is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product |
Demilitarization Code: | Q | Strategic List Item (SLI). Demilitarization not required. SLI are non-MLI(Munitions List Items) controlled by the U.S. Dept. of Commerce through the Export Administration Regulations (EAR) and indicated on the Commerce Control List (CCL). Each CCL entry is preceded by a four-digit Export Control Commerce Control List Item (CCLI) – MUT to the point of scrap required outside the United States. Inside the United States, MUT is required when the DEMIL integrity code (IC) is “3” and MUT is not required when the DEMIL IC is “6.” |
Precious Metals Indicator Code: | U | Precious metal type is unknown |
Criticality Code: | X | The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. |
Category | Code | Description |
---|---|---|
No Freight Information |