Product Details | TEST ADAPTER

6625-01-135-1846 An adapter which provides facilities for electrically connecting an item to be tested and a piece of test equipment. Do not use for interconnecting cables. Includes plug-in electronic component socket adapters which provide terminations for dynamic testing while an electronic component is inserted. See also COUPLER, TEST SET.20649200058Aircraft Maintenance and Repair Shop Specialized Equipment49310062Fire Control Maintenance and Repair Shop Specialized Equipment49330057Weapons Maintenance and Repair Shop Specialized Equipment49350070Guided Missile Maintenance, Repair, and Checkout Specialized Equipment49400063Miscellaneous Maintenance and Repair Shop Specialized Equipment66250070Electrical and Electronic Properties Measuring and Testing Instruments

Part Alternates: 707288-801, 6625-01-135-1846, 01-135-1846, 6625011351846, 707288801, 011351846

Instruments and Laboratory Equipment | Electrical and Electronic Properties Measuring and Testing Instruments

Supply Group (FSG) NSN Assign. NIIN
66 18 JUL 1982 01-135-1846

Cross Reference | NSN 6625-01-135-1846

Part Number Cage Code Manufacturer
707288-801 37695 RAYTHEON COMPANY DBA RAYTHEON

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 6625-01-135-1846

Technical Data | NSN 6625-01-135-1846

Characteristic Specifications
TEST ITEM CONNECTION METHOD CABLE
FREQUENCY RANGE NOT RATED
DC VOLTAGE RATING 24.0 VOLTS MINIMUM AND 25.0 VOLTS MAXIMUM
OVERALL LENGTH 20.000 INCHES NOMINAL
OVERALL WIDTH 8.000 INCHES NOMINAL
OVERALL HEIGHT 16.000 INCHES NOMINAL
SPECIAL FEATURES UHF RADIO TEST SET ADAPTER EXTENDER FOR THE AN/URC-117 GROUND WAVE EMERGENCY NETWORK (GWEN)
III UNPACKAGED UNIT WEIGHT 18.000 POUNDS
III END ITEM IDENTIFICATION 5820-01-108-6622 RADIO SET,AN/VRC-83(V)

Restrictions/Controls & Freight Information | NSN 6625-01-135-1846

Category Code Description
Shelf-Life Code:0Nondeteriorative
Hazardous Material Indicator CodePThere is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product
Demilitarization Code:BMunitions List Item - Mutilation (MUT) to the point of scrap required. (Formerly: Demilitarization not required. Trade Security Controls (TSCs) required at disposition.)
Controlled Inventory Item Code:UUNCLASSIFIED
Precious Metals Indicator Code:AItem does not contain precious metal
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Automatic Data Processing Equipment:0Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)
Category Code Description
NMF Description 061700 ELEC APPLIANCES/INSTRUMENTS NOI
Less than car load rating M 85
Less than truck load rating J 100.2
Water commodity Code 738 unknown
Originating Activity Code TA Sacramento Air Logistics Center
McClellan AFB, CA 95652-5609
Air Dimension Code A Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Air Commodity H Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
Air Special Handling Q Extremely fragile items including delicate instruments.
Special Handling Code 9 unknonwn
HAZMAT
Type of Cargo Z No special type of cargo code applicable

Management | NSN 6625-01-135-1846

Category Code Description
Materiel Management Aggregation CodeRYTG:RADIO/TV (FSC RESIDUAL MMAC)
Price ValidationX The current standard price has been validated and the previous price was erroneous.
  • The item was overpriced and the contractor has refunded the overcharge or DoD activities did not actually pay the previous price. The price paid is within the analyzed acceptable range.
  • If the difference from the previous price exceeds $99.99, or if the price change exceeds 500 percent and the extended value of any affected transaction exceeds $99.99, then reverse-post procedures will apply where the stock fund has overcharged unit O&M Funds. These corrections will be limited to the current fiscal year.
    • ZOP or Standard Price challenges are permissible, but should be supported by adequate justification
Budget CodeY variousO & M:AF centrally procured equipment items. They are separate, primary end items (other than the weapon system itself) needed by a user to perform an assigned mission. They are nonexpendable items (ERRCD NF or ND) which are not consumed in use, and they do not lose their original identity during periods of use by incorporation into, or attachment to another assembly.
Source of SupplyFLZWarner Robins Air Logistics Center
Robins AFB, GA 31098-5609
AgencyDFDepartment of the Air Force
Service OrganizationLLead Service - 22 (Repairable)
ReparabilitySAF Equipment Management System (AFEMS)
Acquisition Advice CodesVTERMINAL ITEM # Identifies items in stock, but future procurement is not authorized. Requisitions may continue to be submitted until stocks are exhausted. Preferred item National Stock Number is normally provided by application of the phrase: When Exhausted Use (NSN). Requisitions will be submitted in accordance with IMM/Service requisitioning procedures as applicable.
Controlled Item CodeUUNCLASSIFIED
Shelf Life Code0Nondeteriorative
Purchasing QTY
UOM
1
EA : Each