Product Details | ELECTRICAL TEST PANEL

6625-01-134-2047 A panel upon which are mounted items such as meters, switches, resistors, jacks, binding posts, and like items, It is designed to be connected to many different types of electrical parts, equipment, or circuits for testing purposes. Do not use for items having specific test applications, such as TESTER (as modified); and TEST SET (as modified).

Part Alternates: 1264TE3, 6625-01-134-2047, 01-134-2047, 6625011342047, 011342047

Instruments and Laboratory Equipment | Electrical and Electronic Properties Measuring and Testing Instruments

Supply Group (FSG) NSN Assign. NIIN
66 30 JUN 1982 01-134-2047

Cross Reference | NSN 6625-01-134-2047

Part Number Cage Code Manufacturer
1264TE3 72314 BAE SYSTEMS INFORMATION AND ELECTRONIC SYSTEMS INTEGRATION I

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 6625-01-134-2047

Technical Data | NSN 6625-01-134-2047

Characteristic Specifications
AC VOLTAGE RATING 115.0 VOLTS NOMINAL
FREQUENCY RATING 400.0 HERTZ NOMINAL
III FSC APPLICATION DATA TEST SET,CAMERA
MANUFACTURERS CODE 72314
DESIGN CONTROL REFERENCE 1264TE3

Restrictions/Controls & Freight Information | NSN 6625-01-134-2047

Category Code Description
Shelf-Life Code:0Nondeteriorative
Hazardous Material Indicator CodePThere is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product
Demilitarization Code:DMunitions List Item or Commerce Control List Item. Demilitarization required. Total destruction of the item and components so as to preclude restoration or repair to a usable condition by melting, cutting, tearing, scratching, crushing, breaking, punching, neutralizing, etc. (As an alternate, burial or deep water dumping may be used when coordinated with the DoD Demilitarization Program Office.)
Controlled Inventory Item Code:7NON-SENSITIVE (SRC-N/A) - UNCLASSIFIED AA&E: OR ITEMS ASSIGNED A DEMILITARIZATION CODE OTHER THAN A, B, Q, OR P FOR WHICH ANOTHER CIIC IS INAPPROPRIATE. (NOTE: THE LOSS, THEFT, UNLAWFUL DISPOSITION, AND/OR RECOVERY OF AN ITEM WITH CIIC 7 WILL BE INVESTIGATED IN ACCORDANCE WITH DOD-4000-25-2-M AND DOD 7200.14-R, VOLUME 12, CHAPTER 7).
Precious Metals Indicator Code:AItem does not contain precious metal
Criticality Code:NThe item does not have a critical feature such as tolerance, fit restrictions or application. Nuclear hardness properties have not been determined (not valid for input).
Automatic Data Processing Equipment:0Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)
Category Code Description
NMF Description 061700 ELEC APPLIANCES/INSTRUMENTS NOI
Less than car load rating W Rating Variable
Less than truck load rating W Rating Variable
Water commodity Code 658 unknown
Originating Activity Code KE Naval ICP
Philadelphia, PA 19111
Air Dimension Code A Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Air Commodity H Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
Air Special Handling Z No special handling required.
Special Handling Code 9 unknonwn
HAZMAT
Type of Cargo Z No special type of cargo code applicable

Management | NSN 6625-01-134-2047

Category Code Description
Cognizance Codes7RAeronautical Depot Level Repairable Spares
Naval Inventory Control Point, Philadelphia
Special Material IDPFFIGHTERAIRCRAFT(F14)
Issue Repair, or RequisitionARRepairable item subject to centrally managed rework program at designated sites. Mandatory turn-in of item required except when initial issue or replacement of surveyed item is involved.
Special Material Content2 Electrostatic Discharge (ESD)/Electromagnetic (EM) Sensitive Item
Source of SupplyNRPNAVICP-ERP
700 Robbins Avenue
Philadelphia, PA 19111-5098
AgencyDNDepartment of the Navy
Service OrganizationLLead Service - 22 (Repairable)
ReparabilityHDepot Level Reparable
Acquisition Advice CodesCSERVICE/AGENCY-MANAGED (Service/Agency use only.) # Issue, transfer, or shipment is not subject to specialized controls other than those imposed by individual Services supply policy. 1. The item is centrally managed, stocked, and issued. 2. Requisitions will be submitted in accordance with Service requisitioning procedures.
Controlled Item Code7NON-SENSITIVE (SRC-N/A) - UNCLASSIFIED AA&E: OR ITEMS ASSIGNED A DEMILITARIZATION CODE OTHER THAN A, B, Q, OR P FOR WHICH ANOTHER CIIC IS INAPPROPRIATE. (NOTE: THE LOSS, THEFT, UNLAWFUL DISPOSITION, AND/OR RECOVERY OF AN ITEM WITH CIIC 7 WILL BE INVESTIGATED IN ACCORDANCE WITH DOD-4000-25-2-M AND DOD 7200.14-R, VOLUME 12, CHAPTER 7).
Shelf Life Code0Nondeteriorative