Product Details | MULTIMETER

6625-01-098-8873 An instrument which is arranged to measure two or more different electrical quantities (such as volts, amps, and ohms) by means of associated circuits and switches. The value is usually expressed on a single calibrated dial or digital readout display. For items which are connected into a circuit and used chiefly to visually monitor an operation, see METER, MULTIPLE SCALE. See also COUNTER, ELECTRONIC, DIGITAL READOUT. Excludes BRIDGE (as modified).

Part Alternates: LO2931, 1128943, 112894-3, 6625-01-098-8873, 01-098-8873, 6625010988873, 010988873

Instruments and Laboratory Equipment | Electrical and Electronic Properties Measuring and Testing Instruments

Supply Group (FSG) NSN Assign. NIIN
66 08 AUG 1980 01-098-8873

Drawings & Photos | NSN 6625-01-098-8873


Cross Reference | NSN 6625-01-098-8873

Part Number Cage Code Manufacturer
112894-3 94271 LOCKHEED MARTIN CORPORATION DBA LOCKHEED MARTIN
LO2931 16236 DLA LAND AND MARITIME

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 6625-01-098-8873

Technical Data | NSN 6625-01-098-8873

Characteristic Specifications
INSTALLATION DESIGN PANEL
(NON-CORE DATA) PANEL FOR WHICH DESIGNED NONMAGNETIC
(NON-CORE DATA) CIRCUIT CONSTRUCTION TYPE NONELECTRONIC
INDICATOR TYPE DIAL W/POINTER
MEASUREMENT RANGE -30.0 TO 40.0 INCHES SINGLE INDICATOR 1ST RANGE 0.0 TO 120.0 PERCENT SINGLE INDICATOR 2ND RANGE
ACCURACY IN PERCENT -1.0 TO 1.0 AT FULL SCALE SINGLE INDICATOR ALL RANGES
SCALE GRADUATION TYPE LINEAR SINGLE INDICATOR ALL RANGES
SCALE DIVISION QUANTITY 70 SINGLE INDICATOR 1ST RANGE 60 SINGLE INDICATOR 2ND RANGE
POINTER COLOR BLACK SINGLE INDICATOR ALL RANGES
DIAL SCALE MARKING COLOR BLACK SINGLE INDICATOR ALL RANGES
BACKGROUND COLOR WHITE SINGLE INDICATOR ALL RANGES
MOVEMENT TYPE MOVING COIL, PERMANENT MAGNET
MOVEMENT SUSPENSION METHOD JEWEL PIVOT BASE
CIRCUIT ATTACHMENT METHOD AND QUANTITY 2 THREADED STUD
SENSITIVITY RATING 1.0 MILLIAMPERES
SCALE SELECTION METHOD TERMINAL
POWER SOURCE EXTERNAL
CIRCUIT CURRENT FOR WHICH DESIGNED DC
STYLE DESIGNATOR C2 RECTANGULAR FLUSH MTG
METER BODY DIAMETER BEHIND MOUNTING FLANGE 3.960 INCHES NOMINAL
METER DEPTH BEHIND MOUNTING FLANGE 2.813 INCHES NOMINAL
OVERALL HEIGHT 4.422 INCHES NOMINAL
OVERALL LENGTH 4.440 INCHES NOMINAL
OVERALL WIDTH 4.422 INCHES NOMINAL
MOUNTING FACILITY TYPE AND QUANTITY 4 THREADED STUD
MOUNTING STUD DIAMETER 0.250 INCHES NOMINAL
MOUNTING STUD LENGTH 0.630 INCHES NOMINAL
MOUNTING ARRANGEMENT STYLE E3 FOUR HOLE/STUD RECTANGULAR/SQUARE
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH 3.380 INCHES NOMINAL
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH 3.380 INCHES NOMINAL
ENVIRONMENTAL PROTECTION SHOCK RESISTANT
FURNISHED ITEMS AND QUANTITY MTG HDW 4; TERM. HDW 2
FEATURES PROVIDED ZERO ADJUSTER
SPECIAL FEATURES ITEM MUST COMPLY WITH REQUIREMENTS OF DEFENSE SUPPLY CENTER COLUMBUS PRODUCTION STANDARD NO. LO2931
REFERENCE NUMBER DIFFERENTIATING CHARACTERISTICS REFERENCE NUMBER DIFFERENTIATING MATERIAL WILL BE IN ACCORDANCE WITH NAVAL INVENTORY CONTROL POINT ACTIVITY HX QUALITY CONTROL. MANUFACTURING AND TESTING SPECIFICATIONS AVAILABLE AT THE DLA ICP
CRITICALITY CODE JUSTIFICATION ZZZY
III FSC APPLICATION DATA TEST SET,ELECT. EQUIP.

Restrictions/Controls & Freight Information | NSN 6625-01-098-8873

Category Code Description
Shelf-Life Code:0Nondeteriorative
Hazardous Material Indicator CodePThere is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product
Demilitarization Code:QStrategic List Item (SLI). Demilitarization not required. SLI are non-MLI(Munitions List Items) controlled by the U.S. Dept. of Commerce through the Export Administration Regulations (EAR) and indicated on the Commerce Control List (CCL). Each CCL entry is preceded by a four-digit Export Control Commerce Control List Item (CCLI) – MUT to the point of scrap required outside the United States. Inside the United States, MUT is required when the DEMIL integrity code (IC) is “3” and MUT is not required when the DEMIL IC is “6.”
Controlled Inventory Item Code:UUNCLASSIFIED
Precious Metals Indicator Code:AItem does not contain precious metal
Criticality Code:YThe item does not have a nuclear hardened feature but does have other critical feature(s) such as tolerance, fit restriction or application.
Automatic Data Processing Equipment:0Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)
Category Code Description
NMF Description 136740 METERS ELEC/PARTS
Less than car load rating
Less than truck load rating W Rating Variable
Water commodity Code 657 unknown
Originating Activity Code TX Defense Supply Center Columbus
Columbus, OH 43218
Air Dimension Code A Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Air Commodity H Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
Air Special Handling Z No special handling required.
Special Handling Code 9 unknonwn
HAZMAT
Type of Cargo Z No special type of cargo code applicable

Management | NSN 6625-01-098-8873

Category Code Description
Cognizance Codes9BNavy-owned stocks of DLA material
Naval Inventory Control Point, Mechanicsburg
Source of SupplySMSDefense Logistics Agency
Enterprise Business Systems
AgencyDNDepartment of the Navy
Service OrganizationNU.S. Navy
Acquisition Advice CodesJNOT STOCKED, CENTRALLY PROCURED # (NON-STOCKED ITEMS) IMM/Service centrally managed but not stocked item. Procurement will be initiated only after receipt of a requisition.
Controlled Item CodeUUNCLASSIFIED
Shelf Life Code0Nondeteriorative
Purchasing QTY
UOM
1
EA : Each