NSN 6625-01-062-7591 204-91600-3, 01-062-7591, 204916003
Product Details | POWER SUPPLY TEST SET
6625-01-062-7591 A group of components primarily designed for making examinations of power supplies. It may include facilities for determining the insulation breakdown qualities of motors, cables, and the like.
Part Alternates: 204-91600-3, 6625-01-062-7591, 01-062-7591, 6625010627591, 204916003, 010627591
Instruments and Laboratory Equipment | Electrical and Electronic Properties Measuring and Testing Instruments
Supply Group (FSG) | NSN Assign. | NIIN | Item Name Code (INC) |
---|---|---|---|
66 | 22 JUL 1978 | 01-062-7591 | 03658 ( TEST SET, POWER SUPPLY ) |
Cross Reference | NSN 6625-01-062-7591
Part Number | Cage Code | Manufacturer |
---|---|---|
204-91600-3 | 81205 | THE BOEING COMPANY DBA BOEING |
Request a Quote
What Our Customers Say
Compare
NSNs for Compare ( up to 4 ): Add 6625-01-062-7591
Related Products | NSN 6625-01-062-7591
Technical Data | NSN 6625-01-062-7591
Characteristic | Specifications |
---|---|
TEST TYPE FOR WHICH DESIGNED | CURRENT; VOLTAGE; RESISTANCE |
OPERATING TEST CAPABILITY | AC V RANGE 0-1000V RMS; PEAK TO PEAK VOLTAGES 0-1500 V PEAK TO PEAK AND 0-25000 V 0 TO PEAK; RESISTANCE RANGE 0-10 MEGOHMS; TIME INTERVAL RANGE 50 NANOSECONDS TO 3 SECONDS |
ELECTRICAL POWER SOURCE RELATIONSHIP | OPERATING |
AC VOLTAGE RATING | 108.0 VOLTS MINIMUM AND 228.8 VOLTS MAXIMUM 108.0 VOLTS MAXIMUM AND 228.8 VOLTS MAXIMUM |
FREQUENCY RATING | 55.0 HERTZ MINIMUM AND 65.0 HERTZ MAXIMUM 380.0 HERTZ MINIMUM AND 420.0 HERTZ MAXIMUM |
PHASE | THREE THREE |
DC VOLTAGE RATING | 0.0 VOLTS MINIMUM AND 40.0 VOLTS MAXIMUM 0.0 VOLTS MINIMUM AND 300.0 VOLTS MAXIMUM |
INTERNAL BATTERY ACCOMMODATION | NOT INCLUDED NOT INCLUDED |
MAJOR COMPONENTS | ADAPTER,TEST; AC VOLTMETER; OSCILLOSCOPE; DC VOLTMETER; PULSE GENERATOR; FUNCTION GERERATOR; DOUBLE RACK; WORK TABLE |
III SUPPLEMENTARY FEATURES | TEST SET WILL PROVIDE ALL REQUIRER COOLING AIR FOR TEST EQUIPMENT,CONTROL PANELS,LOADS WITHIN TEST CONSOLES |
MANUFACTURERS CODE | 81205 |
DESIGN CONTROL REFERENCE | 204-91600-3 |
Restrictions/Controls & Freight Information | NSN 6625-01-062-7591
Category | Code | Description |
---|---|---|
Shelf-Life Code: | 0 | Nondeteriorative |
Hazardous Material Indicator Code | P | There is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product |
Demilitarization Code: | A | Non-Munitions List Item/ Non-Strategic List Item - Demilitarization not required. |
Controlled Inventory Item Code: | U | UNCLASSIFIED |
Precious Metals Indicator Code: | A | Item does not contain precious metal |
Criticality Code: | X | The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. |
Automatic Data Processing Equipment: | 0 | Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9) |
Category | Code | Description |
---|---|---|
NMF Description | 061700 | ELEC APPLIANCES/INSTRUMENTS NOI |
Less than car load rating | P | 77.5 |
Less than truck load rating | J | 100.2 |
Water commodity Code | 738 | unknown |
Originating Activity Code | SE | San Antonio Air Logistics Center Kelly AFB, TX 78241-5000 |
Air Dimension Code | A | Shipment is not a consolidation and does not exceed 72 inches in any dimension. |
Air Commodity | H | Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc. |
Air Special Handling | Q | Extremely fragile items including delicate instruments. |
Special Handling Code | 9 | unknonwn |
HAZMAT | ||
Type of Cargo | 3 | Electrostatic Sensitive Device (ESD), subject to damage caused by electrostatic discharge. (See DoD 4500.32-R, Volume 1, Appendix A, Section I for additional information on ESD devices). |
Management | NSN 6625-01-062-7591
Category | Code | Description |
---|---|---|
Price Validation | N | The current standard price in Catalog Management Data (CMD) has not analyzed or coded for LP/LM.
|
Materiel Management Aggregation Code | RH | TG:AUTO TEST EQUIPMENT/AUTO TEST SYSTEMS (ATE/ATS) (FSC RESIDUAL MMAC) |
Budget Code | Y | variousO & M:AF centrally procured equipment items. They are separate, primary end items (other than the weapon system itself) needed by a user to perform an assigned mission. They are nonexpendable items (ERRCD NF or ND) which are not consumed in use, and they do not lose their original identity during periods of use by incorporation into, or attachment to another assembly. |
Source of Supply | FLZ | Warner Robins Air Logistics Center Robins AFB, GA 31098-5609 |
Agency | DF | Department of the Air Force |
Service Organization | L | Lead Service - 22 (Repairable) |
Reparability | S | AF Equipment Management System (AFEMS) |
Acquisition Advice Codes | V | TERMINAL ITEM # Identifies items in stock, but future procurement is not authorized. Requisitions may continue to be submitted until stocks are exhausted. Preferred item National Stock Number is normally provided by application of the phrase: When Exhausted Use (NSN). Requisitions will be submitted in accordance with IMM/Service requisitioning procedures as applicable. |
Controlled Item Code | U | UNCLASSIFIED |
Shelf Life Code | 0 | Nondeteriorative |
Purchasing | QTY UOM |
1 EA : Each |