Product Details | SIGNAL GENERATOR

6625-01-008-2602 An instrument which produces a continuous audio and/or radio frequency voltage, and which is designed for test purposes only. It may provide an output at one or more fixed frequencies or be continuously variable over one or more bands. The fixed frequency type is distinguished from CALIBRATOR, FREQUENCY in that it is a voltage source and is not primarily intended for checking frequencies from other sources. Excludes GENERATOR, INTERFERENCE.

Part Alternates: 1606B, 6625-01-008-2602, 01-008-2602, 6625010082602, 010082602

Instruments and Laboratory Equipment | Electrical and Electronic Properties Measuring and Testing Instruments

Supply Group (FSG) NSN Assign. NIIN
66 19 AUG 1975 01-008-2602

Cross Reference | NSN 6625-01-008-2602

Part Number Cage Code Manufacturer
1606B 82199 ROHDE & SCHWARZ USA, INC.

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 6625-01-008-2602

Technical Data | NSN 6625-01-008-2602

Characteristic Specifications
FREQUENCY RANGE RATING 1.800 TO 4.600 GIGAHERTZ
FREQUENCY BAND QUANTITY 1
MODULATOR LOCATION ANY ACCEPTABLE
MODULATION TYPE FM AND PULSE AND SQUARE WAVE
MODULATION DEGREE 2.0 USEC PULSE MINIMUM AND 2000.0 USEC PULSE MAXIMUM
CURRENT TYPE AC
FREQUENCY RATING 50.0 HERTZ MINIMUM AND 60.0 HERTZ MAXIMUM
PHASE SINGLE
CASE MATERIAL METAL
OVERALL LENGTH 17.000 INCHES NOMINAL
OVERALL WIDTH 16.750 INCHES NOMINAL
OVERALL HEIGHT 7.000 INCHES NOMINAL
MOUNTING TYPE BENCH
III FUNCTIONAL CLASSIFICATION BB-1.1
III ENTRY DATE 90-10-11
MANUFACTURERS CODE 82199
DESIGN CONTROL REFERENCE 1606B

Restrictions/Controls & Freight Information | NSN 6625-01-008-2602

Category Code Description
Hazardous Material Indicator CodePThere is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product
Demilitarization Code:ANon-Munitions List Item/ Non-Strategic List Item - Demilitarization not required.
Electro-static Discharge Susceptible:ANo known Electrostatic Discharge (ESD) or Electromagnetic Interference (EMI) sensitivity
Precious Metals Indicator Code:AItem does not contain precious metal
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Automatic Data Processing Equipment:0Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)
Category Code Description
NMF Description 061700 ELEC APPLIANCES/INSTRUMENTS NOI
Less than car load rating P 77.5
Less than truck load rating W Rating Variable
Water commodity Code 72D unknown
Originating Activity Code SE San Antonio Air Logistics Center
Kelly AFB, TX 78241-5000
Air Dimension Code A Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Air Commodity
Air Special Handling Q Extremely fragile items including delicate instruments.
Special Handling Code Q unknonwn
HAZMAT
Type of Cargo Z No special type of cargo code applicable