NSN 6625-00-902-7571 117A, 00-902-7571, 009027571
Product Details | SIGNAL COMPARATOR
6625-00-902-7571 A component which correlates information from two or more signals. For similar items having modular characteristics, see COMPARATOR MODULE, SIGNAL.20258950037Miscellaneous Communication Equipment66250070Electrical and Electronic Properties Measuring and Testing Instruments
Part Alternates: 117A, 6625-00-902-7571, 00-902-7571, 6625009027571, 009027571
Instruments and Laboratory Equipment | Electrical and Electronic Properties Measuring and Testing Instruments
Supply Group (FSG) | NSN Assign. | NIIN | Item Name Code (INC) |
---|---|---|---|
66 | 01 JAN 1960 | 00-902-7571 | 00324 ( COMPARATOR, SIGNAL ) |
Request a Quote
What Our Customers Say
Compare
NSNs for Compare ( up to 4 ): Add 6625-00-902-7571
Related Products | NSN 6625-00-902-7571
Technical Data | NSN 6625-00-902-7571
Characteristic | Specifications |
---|---|
INDICATOR TYPE | CHART RECORDING AND METER |
ELECTRICAL POWER SOURCE RELATIONSHIP | OPERATING |
AC VOLTAGE RATING | 115.0 VOLTS NOMINAL 230.0 VOLTS NOMINAL |
FREQUENCY RATING | 60.0 HERTZ NOMINAL |
PHASE | SINGLE |
INTERNAL BATTERY ACCOMMODATION | NOT INCLUDED |
EXTERNAL CONTROL | POWER SWITCH,METER FUNCTION SWITCH,AND CHART WIDTH ADJUSTMENT SWITCH |
INPUT IMPEDANCE RATING | 1.0 KILOHMS NOMINAL |
OUTPUT IMPEDANCE RATING | 5.0 KILOHMS NOMINAL |
OPERATING FREQUENCY | 60.0 KILOHERTZ MINIMUM AND 100.0 KILOHERTZ MAXIMUM |
SPECIAL FEATURES | 3.791 IN. BY 13.250 IN. BY 16.750 IN. O/A DIM. |
III FSC APPLICATION DATA | TEST SET,ELECTRONIC SYSTEMS,EXCEPT SPECIALLY DESIGNED |
MANUFACTURERS CODE | 1LQK8 |
DESIGN CONTROL REFERENCE | 117A |
Restrictions/Controls & Freight Information | NSN 6625-00-902-7571
Category | Code | Description |
---|---|---|
Shelf-Life Code: | 0 | Nondeteriorative |
Hazardous Material Indicator Code | P | There is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product |
Demilitarization Code: | Q | Strategic List Item (SLI). Demilitarization not required. SLI are non-MLI(Munitions List Items) controlled by the U.S. Dept. of Commerce through the Export Administration Regulations (EAR) and indicated on the Commerce Control List (CCL). Each CCL entry is preceded by a four-digit Export Control Commerce Control List Item (CCLI) – MUT to the point of scrap required outside the United States. Inside the United States, MUT is required when the DEMIL integrity code (IC) is “3” and MUT is not required when the DEMIL IC is “6.” |
Controlled Inventory Item Code: | U | UNCLASSIFIED |
Precious Metals Indicator Code: | U | Precious metal type is unknown |
Criticality Code: | X | The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. |
Automatic Data Processing Equipment: | 0 | Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9) |
Category | Code | Description |
---|---|---|
NMF Description | 061700 | ELEC APPLIANCES/INSTRUMENTS NOI |
Less than car load rating | P | 77.5 |
Less than truck load rating | J | 100.2 |
Water commodity Code | 738 | unknown |
Originating Activity Code | XX | |
Air Dimension Code | A | Shipment is not a consolidation and does not exceed 72 inches in any dimension. |
Air Commodity | H | Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc. |
Air Special Handling | Z | No special handling required. |
Special Handling Code | 9 | unknonwn |
HAZMAT | ||
Type of Cargo | 3 | Electrostatic Sensitive Device (ESD), subject to damage caused by electrostatic discharge. (See DoD 4500.32-R, Volume 1, Appendix A, Section I for additional information on ESD devices). |
Management | NSN 6625-00-902-7571
Category | Code | Description |
---|---|---|
Price Validation | N | The current standard price in Catalog Management Data (CMD) has not analyzed or coded for LP/LM.
|
Materiel Management Aggregation Code | RH | TG:AUTO TEST EQUIPMENT/AUTO TEST SYSTEMS (ATE/ATS) (FSC RESIDUAL MMAC) |
Budget Code | Y | variousO & M:AF centrally procured equipment items. They are separate, primary end items (other than the weapon system itself) needed by a user to perform an assigned mission. They are nonexpendable items (ERRCD NF or ND) which are not consumed in use, and they do not lose their original identity during periods of use by incorporation into, or attachment to another assembly. |
Source of Supply | FLZ | Warner Robins Air Logistics Center Robins AFB, GA 31098-5609 |
Agency | DF | Department of the Air Force |
Service Organization | L | Lead Service - 22 (Repairable) |
Reparability | S | AF Equipment Management System (AFEMS) |
Acquisition Advice Codes | V | TERMINAL ITEM # Identifies items in stock, but future procurement is not authorized. Requisitions may continue to be submitted until stocks are exhausted. Preferred item National Stock Number is normally provided by application of the phrase: When Exhausted Use (NSN). Requisitions will be submitted in accordance with IMM/Service requisitioning procedures as applicable. |
Controlled Item Code | U | UNCLASSIFIED |
Shelf Life Code | 0 | Nondeteriorative |
Purchasing | QTY UOM |
1 EA : Each |