NSN 6625-00-820-0119 TS1389U, 624N, 00-820-0119
Product Details | RADIO FREQUENCY POWER TEST SET
6625-00-820-0119 A test set primarily designed for use in making examinations of the power output of radio frequency oscillators and radio and radar transmitters. See also TEST SET, ELECTRICAL POWER; and WATTMETER.20211900057Specialized Test and Handling Equipment, Nuclear Ordnance66250070Electrical and Electronic Properties Measuring and Testing Instruments
Part Alternates: TS1389U, 624N, 6625-00-820-0119, 00-820-0119, 6625008200119, 008200119
Instruments and Laboratory Equipment | Electrical and Electronic Properties Measuring and Testing Instruments
Supply Group (FSG) | NSN Assign. | NIIN | Item Name Code (INC) |
---|---|---|---|
66 | 01 JAN 1962 | 00-820-0119 | 21191 ( TEST SET, RADIO FREQUENCY POWER ) |
Request a Quote
What Our Customers Say
Compare
NSNs for Compare ( up to 4 ): Add 6625-00-820-0119
Related Products | NSN 6625-00-820-0119
Technical Data | NSN 6625-00-820-0119
Characteristic | Specifications |
---|---|
INPUT FREQUENCY RANGE | 1.000 TO 1000.000 MEGAHERTZ |
RADIO FREQUENCY INPUT POWER RATING | 10.0 MILLIWATTS MINIMUM AND 4.0 WATTS MAXIMUM |
INPUT IMPEDANCE RATING | 51.5 OHMS NOMINAL |
MEASUREMENT UNIT | AVERAGE POWER |
SCALE UNIT OF MEASURE INSCRIPTION | WATTS |
SCALE DIRECTION AND RANGE | 0 TO 4 CLOCKWISE |
MATERIAL AND LOCATION | STEEL HOUSING |
SURFACE TREATMENT | PAINT |
LENGTH | 5.750 INCHES NOMINAL |
HEIGHT | 4.250 INCHES NOMINAL |
WIDTH | 4.250 INCHES NOMINAL |
JOINT ELECTRONICS TYPE DESIGNATION SYSTEM ITEM NAME | TEST SET,RADIO FREQUENCY POWER |
JOINT ELECTRONICS TYPE DESIGNATION SYSTEM ITEM TYPE NUMBER | TS-1389/U |
Restrictions/Controls & Freight Information | NSN 6625-00-820-0119
Category | Code | Description |
---|---|---|
Shelf-Life Code: | 0 | Nondeteriorative |
Hazardous Material Indicator Code | P | There is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product |
Demilitarization Code: | A | Non-Munitions List Item/ Non-Strategic List Item - Demilitarization not required. |
Controlled Inventory Item Code: | U | UNCLASSIFIED |
Precious Metals Indicator Code: | A | Item does not contain precious metal |
Criticality Code: | X | The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. |
Automatic Data Processing Equipment: | 0 | Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9) |
Category | Code | Description |
---|---|---|
NMF Description | 061700 | ELEC APPLIANCES/INSTRUMENTS NOI |
Less than car load rating | ||
Less than truck load rating | W | Rating Variable |
Water commodity Code | 658 | unknown |
Originating Activity Code | XX | |
Air Dimension Code | A | Shipment is not a consolidation and does not exceed 72 inches in any dimension. |
Air Commodity | H | Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc. |
Air Special Handling | Z | No special handling required. |
Special Handling Code | 9 | unknonwn |
HAZMAT | ||
Type of Cargo | Z | No special type of cargo code applicable |
Management | NSN 6625-00-820-0119
Category | Code | Description |
---|---|---|
Stores Account Code | 1 | Marine Corps Stock Fund Account Item. |
Combat Essentiality Code | 5 | Critical Repair Part to a Combat Essential End Item. Those parts or components whose failure in a combat essential end item will render the end item inoperative or reduce its effectiveness below the minimum acceptable level of efficiency. |
Materiel Management Code | B | All CommoditiesDefense Logistics Agency, (DLA,) |
Echelon Management Code | 2 | ICP/DSSC Marine Corps-managed Recoverability Code D items and Defense Logistics Agency (DLA)/TACOM/GSA) items which the integrated manager has not decontrolled. |
Operational Test Code | 3 | All items requiring calibration. Items may be technical or non-technical in nature, (i.e., electronic test equipment, meters, gauges, torque wrenches, etc.) All OTC 3 items require established calibration procedures.BLANK |
Physical Category Code | 1 | Bin |
Source of Supply | SMS | Defense Logistics Agency Enterprise Business Systems |
Agency | DM | U.S. Marine Corps |
Service Organization | M | U.S. Marine Corps |
Reparability | F | Reparable item. When uneconomically reparable, condemn and dispose at the third echelon level. |
Acquisition Advice Codes | V | TERMINAL ITEM # Identifies items in stock, but future procurement is not authorized. Requisitions may continue to be submitted until stocks are exhausted. Preferred item National Stock Number is normally provided by application of the phrase: When Exhausted Use (NSN). Requisitions will be submitted in accordance with IMM/Service requisitioning procedures as applicable. |
Controlled Item Code | U | UNCLASSIFIED |
Shelf Life Code | 0 | Nondeteriorative |