Product Details | INSULATION BREAKDOWN TEST SET

6625-00-801-3863 A test set primarily designed to detect and indicate insulation breakdown in electric motors, transformers, and the like, at specific test voltages. See also TEST SET, ARMATURE; and OHMMETER.

Part Alternates: 106-2.5W, 10625, 106-2-5, 10625W, 6625-00-801-3863, 00-801-3863, 6625008013863, 008013863

Instruments and Laboratory Equipment | Electrical and Electronic Properties Measuring and Testing Instruments

Supply Group (FSG) NSN Assign. NIIN
66 01 JAN 1962 00-801-3863

Cross Reference | NSN 6625-00-801-3863

Part Number Cage Code Manufacturer
106-2-5 05611 STS INSTRUMENTS INC.
106-2.5W 05611 STS INSTRUMENTS INC.

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 6625-00-801-3863

Technical Data | NSN 6625-00-801-3863

Characteristic Specifications
OUTPUT CURRENT TYPE AC
OUTPUT VOLTAGE RATING 2.500 KILOVOLTS NOMINAL
OUTPUT FREQUENCY RATING 60.000 HERTZ NOMINAL
VOLT-AMPERE RATING 75.000
INSTALLATION DESIGN PORTABLE
METER QUANTITY 1
METER TYPE VOLTMETER
SCALE RANGE 0.0 TO 2500.0 VOLTS
TEST LEAD QUANTITY 2
WIRE LEAD LENGTH 48.000 INCHES NOMINAL
WIRE TERMINATION TYPE PROD
AC VOLTAGE RATING 117.0 VOLTS NOMINAL
FREQUENCY RATING 60.000 HERTZ NOMINAL
PHASE SINGLE
OVERALL DEPTH 6.000 INCHES NOMINAL
OVERALL LENGTH 9.000 INCHES NOMINAL
OVERALL WIDTH 7.000 INCHES NOMINAL
MANUFACTURERS CODE 05611
DESIGN CONTROL REFERENCE 106-2.5W

Restrictions/Controls & Freight Information | NSN 6625-00-801-3863

Category Code Description
Shelf-Life Code:0Nondeteriorative
Hazardous Material Indicator CodePThere is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product
Demilitarization Code:QStrategic List Item (SLI). Demilitarization not required. SLI are non-MLI(Munitions List Items) controlled by the U.S. Dept. of Commerce through the Export Administration Regulations (EAR) and indicated on the Commerce Control List (CCL). Each CCL entry is preceded by a four-digit Export Control Commerce Control List Item (CCLI) – MUT to the point of scrap required outside the United States. Inside the United States, MUT is required when the DEMIL integrity code (IC) is “3” and MUT is not required when the DEMIL IC is “6.”
Controlled Inventory Item Code:UUNCLASSIFIED
Precious Metals Indicator Code:AItem does not contain precious metal
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Automatic Data Processing Equipment:0Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)
Category Code Description
NMF Description 061700 ELEC APPLIANCES/INSTRUMENTS NOI
Less than car load rating P 77.5
Less than truck load rating J 100.2
Water commodity Code 738 unknown
Originating Activity Code XX
Air Dimension Code A Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Air Commodity H Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
Air Special Handling Q Extremely fragile items including delicate instruments.
Special Handling Code 9 unknonwn
HAZMAT
Type of Cargo 3 Electrostatic Sensitive Device (ESD), subject to damage caused by electrostatic discharge. (See DoD 4500.32-R, Volume 1, Appendix A, Section I for additional information on ESD devices).

Management | NSN 6625-00-801-3863

Category Code Description
Materiel Management Aggregation CodeRHTG:AUTO TEST EQUIPMENT/AUTO TEST SYSTEMS (ATE/ATS) (FSC RESIDUAL MMAC)
Price ValidationX The current standard price has been validated and the previous price was erroneous.
  • The item was overpriced and the contractor has refunded the overcharge or DoD activities did not actually pay the previous price. The price paid is within the analyzed acceptable range.
  • If the difference from the previous price exceeds $99.99, or if the price change exceeds 500 percent and the extended value of any affected transaction exceeds $99.99, then reverse-post procedures will apply where the stock fund has overcharged unit O&M Funds. These corrections will be limited to the current fiscal year.
    • ZOP or Standard Price challenges are permissible, but should be supported by adequate justification
Budget CodeY variousO & M:AF centrally procured equipment items. They are separate, primary end items (other than the weapon system itself) needed by a user to perform an assigned mission. They are nonexpendable items (ERRCD NF or ND) which are not consumed in use, and they do not lose their original identity during periods of use by incorporation into, or attachment to another assembly.
Source of SupplyFLZWarner Robins Air Logistics Center
Robins AFB, GA 31098-5609
AgencyDFDepartment of the Air Force
Service OrganizationLLead Service - 22 (Repairable)
ReparabilityUAF Equipment Management System (AFEMS)
Acquisition Advice CodesVTERMINAL ITEM # Identifies items in stock, but future procurement is not authorized. Requisitions may continue to be submitted until stocks are exhausted. Preferred item National Stock Number is normally provided by application of the phrase: When Exhausted Use (NSN). Requisitions will be submitted in accordance with IMM/Service requisitioning procedures as applicable.
Controlled Item CodeUUNCLASSIFIED
Shelf Life Code0Nondeteriorative
Purchasing QTY
UOM
1
EA : Each