NSN 6625-00-581-0274 7423640-10, 00-581-0274, 742364010
Product Details | ELECTRICAL POWER TEST SET
6625-00-581-0274 A test set primarily designed for use in making examinations of electrical power generating or converting equipments and/or transmission systems. See also TEST SET, VIBRATOR; WATTMETER; METER, POWER FACTOR; METER, ELECTRICAL FREQUENCY; and TEST SET, RADIO FREQUENCY POWER.
Part Alternates: 7423640-10, 6625-00-581-0274, 00-581-0274, 6625005810274, 742364010, 005810274
Instruments and Laboratory Equipment | Electrical and Electronic Properties Measuring and Testing Instruments
Supply Group (FSG) | NSN Assign. | NIIN | Item Name Code (INC) |
---|---|---|---|
66 | 19 DEC 1974 | 00-581-0274 | 03637 ( TEST SET, ELECTRICAL POWER ) |
Request a Quote
What Our Customers Say
Compare
NSNs for Compare ( up to 4 ): Add 6625-00-581-0274
Related Products | NSN 6625-00-581-0274
Technical Data | NSN 6625-00-581-0274
Characteristic | Specifications |
---|---|
TEST TYPE FOR WHICH DESIGNED | POWER |
OPERATING TEST CAPABILITY | VOLTMETER RANGE 0-200 VOLTS DC; AMMETER RANGE 0-200 MILLAMPERES DC |
ELECTRICAL POWER SOURCE RELATIONSHIP | SELF-CONTAINED |
INCLOSURE FEATURE | SINGLE ITEM W/CARRYING CASE |
HEIGHT | 5.500 INCHES NOMINAL |
LENGTH | 11.000 INCHES NOMINAL |
WIDTH | 9.000 INCHES NOMINAL |
MAJOR COMPONENTS | CABLE ASSEMBLY |
ACCESSORY COMPONENT QUANTITY | 1 AND 1 |
ACCESSORY CONTROLLING AGENCY | SANDIA LABORATORIES |
ACCESSORY IDENTIFYING NUMBER | 7423645-10 PART NO. AND 7423646-10 PART NO. |
JOINT ELECTRONICS TYPE DESIGNATION SYSTEM ITEM NAME | TEST SET,ELECTRICAL POWER |
JOINT ELECTRONICS TYPE DESIGNATION SYSTEM ITEM TYPE NUMBER | AN/GSM-254 |
SPECIAL FEATURES | PROVIDES MANUALLY VARIABLE LOAD AND VOLTAGE AND CURRENT MONITORING CAPABILITIES FOR TESTING CURRENT LIMITING CIRCUITS IN THE ACADS SYSTEM; WATERPROOF |
MANUFACTURERS CODE | 50464 |
DESIGN CONTROL REFERENCE | 7423640-10 |
Restrictions/Controls & Freight Information | NSN 6625-00-581-0274
Category | Code | Description |
---|---|---|
Shelf-Life Code: | 0 | Nondeteriorative |
Hazardous Material Indicator Code | P | There is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product |
Demilitarization Code: | Q | Strategic List Item (SLI). Demilitarization not required. SLI are non-MLI(Munitions List Items) controlled by the U.S. Dept. of Commerce through the Export Administration Regulations (EAR) and indicated on the Commerce Control List (CCL). Each CCL entry is preceded by a four-digit Export Control Commerce Control List Item (CCLI) – MUT to the point of scrap required outside the United States. Inside the United States, MUT is required when the DEMIL integrity code (IC) is “3” and MUT is not required when the DEMIL IC is “6.” |
Controlled Inventory Item Code: | U | UNCLASSIFIED |
Precious Metals Indicator Code: | A | Item does not contain precious metal |
Criticality Code: | X | The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. |
Category | Code | Description |
---|---|---|
NMF Description | 061700 | ELEC APPLIANCES/INSTRUMENTS NOI |
Less than car load rating | P | 77.5 |
Less than truck load rating | W | Rating Variable |
Water commodity Code | 657 | unknown |
Originating Activity Code | SE | San Antonio Air Logistics Center Kelly AFB, TX 78241-5000 |
Air Dimension Code | A | Shipment is not a consolidation and does not exceed 72 inches in any dimension. |
Air Commodity | H | Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc. |
Air Special Handling | Q | Extremely fragile items including delicate instruments. |
Special Handling Code | Q | unknonwn |
HAZMAT | ||
Type of Cargo | Z | No special type of cargo code applicable |
Management | NSN 6625-00-581-0274
Category | Code | Description |
---|---|---|
Budget Code | K | 8357X3080:Cryptologic and Other USAF Security Service Equipment |
Price Validation | N | The current standard price in Catalog Management Data (CMD) has not analyzed or coded for LP/LM.
|
Materiel Management Aggregation Code | SM | SJ:MISSION AND SECURITY PRODUCTS |
Source of Supply | FPD | Air Force Cryptologic Support Center (ESC) San Antonio, TX 78243-5000 |
Agency | DF | Department of the Air Force |
Service Organization | L | Lead Service - 22 (Repairable) |
Reparability | U | AF Equipment Management System (AFEMS) |
Acquisition Advice Codes | X | SEMIACTIVE ITEM-NO REPLACEMENT (NON-STOCKED ITEMS) A potentially inactive NSN which must be retained in the supply system as an item of supply because (1) stocks of the item are on hand or in use below the wholesale level and (2) the NSN is cited in equipment authorization documents TO & E, TA, TM, etc., or in-use assets are being reported. 1. Items are authorized for central procurement but not authorized for stockage at wholesale level. 2. Requisitions for in-use replacement will be authorized in accordance with individual Military Service directives. 3. Requisitions may be submitted as requirements generate. Repetitive demands may dictate an AAC change to permit wholesale stockage. |
Controlled Item Code | U | UNCLASSIFIED |
Shelf Life Code | 0 | Nondeteriorative |