Product Details | VOLTMETER

6625-00-580-5298 An instrument which measures electrical potential and is calibrated in volts or any multiple and/or submultiple thereof. The value may be expressed by means of a pointer and calibrated dial or a digital readout display.

Part Alternates: ME30BU, 513C148, 6625-00-580-5298, 00-580-5298, 6625005805298, 005805298

Instruments and Laboratory Equipment | Electrical and Electronic Properties Measuring and Testing Instruments

Supply Group (FSG) NSN Assign. NIIN
66 01 JAN 1963 00-580-5298

Drawings & Photos | NSN 6625-00-580-5298


Cross Reference | NSN 6625-00-580-5298

Part Number Cage Code Manufacturer
513C148 26687 TELEDYNE TECHNOLOGIES INCORPORATED DBA TELEDYNE
ME30BU 80058 JOINT ELECTRONICS TYPE DESIGNATION SYSTEM

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 6625-00-580-5298

Technical Data | NSN 6625-00-580-5298

Characteristic Specifications
SENSITIVITY RATING 1.0 MILLIAMPERES
SCALE SELECTION METHOD SWITCH
POWER SOURCE EXTERNAL
FREQUENCY RATING 50.000 HERTZ MINIMUM AND 1.000 KILOHERTZ MAXIMUM
PHASE SINGLE
STYLE DESIGNATOR D1 RECTANGULAR OR SQUARE
OVERALL HEIGHT 8.250 INCHES NOMINAL
OVERALL LENGTH 8.000 INCHES NOMINAL
OVERALL WIDTH 12.000 INCHES NOMINAL
SURFACE TREATMENT ENAMEL
FURNISHED ITEMS AND QUANTITY STRAP,CARRYING 1
FEATURES PROVIDED ZERO ADJUSTER AND ZERO ADJUSTER
SPECIAL FEATURES NONLINEAR DECIBEL SCALE
MANUFACTURERS CODE 26687
DESIGN CONTROL REFERENCE 513C148

Restrictions/Controls & Freight Information | NSN 6625-00-580-5298

Category Code Description
Shelf-Life Code:0Nondeteriorative
Hazardous Material Indicator CodePThere is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product
Demilitarization Code:ANon-Munitions List Item/ Non-Strategic List Item - Demilitarization not required.
Controlled Inventory Item Code:UUNCLASSIFIED
Precious Metals Indicator Code:AItem does not contain precious metal
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Automatic Data Processing Equipment:0Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)
Category Code Description
NMF Description 061620 ELECTRIC CURRENT TESTERS
Less than car load rating J 100.2
Less than truck load rating J 100.2
Water commodity Code 658 unknown
Originating Activity Code XX
Air Dimension Code A Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Air Commodity H Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
Air Special Handling Z No special handling required.
Special Handling Code 9 unknonwn
HAZMAT
Type of Cargo Z No special type of cargo code applicable

Management | NSN 6625-00-580-5298

Category Code Description
Stores Account Code1Marine Corps Stock Fund Account Item.
Combat Essentiality Code5Critical Repair Part to a Combat Essential End Item. Those parts or components whose failure in a combat essential end item will render the end item inoperative or reduce its effectiveness below the minimum acceptable level of efficiency.
Materiel Management Code4Communications/Electronics Materiel5445, 58, 59, 60, 61, 6625, 6660, 6665
Echelon Management Code1ICP All Marine Corps-managed items which have not been assigned to integrated materiel management and which are centrally managed by the inventory control point on a system-wide basis.
Echelon Identification CodeAType 1 End Items 1
Operational Test Code3All items requiring calibration. Items may be technical or non-technical in nature, (i.e., electronic test equipment, meters, gauges, torque wrenches, etc.) All OTC 3 items require established calibration procedures.BLANK
Source of SupplyMPBCommanding General
Marine Corps Logistics Command
566-2, Bldg. 3700
Albany, GA 31704-5000
AgencyDMU.S. Marine Corps
Service OrganizationMU.S. Marine Corps
ReparabilityZNonreparable item. When unserviceable, condemn and dispose at the level indicated by the first digit of the maintenance code.
Acquisition Advice CodesVTERMINAL ITEM # Identifies items in stock, but future procurement is not authorized. Requisitions may continue to be submitted until stocks are exhausted. Preferred item National Stock Number is normally provided by application of the phrase: When Exhausted Use (NSN). Requisitions will be submitted in accordance with IMM/Service requisitioning procedures as applicable.
Controlled Item CodeUUNCLASSIFIED
Shelf Life Code0Nondeteriorative
Category Code Description
Cognizance Codes7ZGeneral purpose electronic test equipment to support various Naval Systems Commands equipment/programs.
Naval Inventory Control Point, Mechanicsburg
Special Material IDTEGeneral purpose electronic test equipment
Special Material Content9 Non-Hazardous or Non-Sensitive Item, does not require hazardous or special handling, packaging or precautions
Source of SupplyNRPNAVICP-ERP
700 Robbins Avenue
Philadelphia, PA 19111-5098
AgencyDNDepartment of the Navy
Service OrganizationLLead Service - 22 (Repairable)
ReparabilityHDepot Level Reparable
Acquisition Advice CodesVTERMINAL ITEM # Identifies items in stock, but future procurement is not authorized. Requisitions may continue to be submitted until stocks are exhausted. Preferred item National Stock Number is normally provided by application of the phrase: When Exhausted Use (NSN). Requisitions will be submitted in accordance with IMM/Service requisitioning procedures as applicable.
Controlled Item CodeUUNCLASSIFIED
Shelf Life Code0Nondeteriorative