Product Details | SIGNAL GENERATOR

6625-00-580-1918 An instrument which produces a continuous audio and/or radio frequency voltage, and which is designed for test purposes only. It may provide an output at one or more fixed frequencies or be continuously variable over one or more bands. The fixed frequency type is distinguished from CALIBRATOR, FREQUENCY in that it is a voltage source and is not primarily intended for checking frequencies from other sources. Excludes GENERATOR, INTERFERENCE.

Part Alternates: I196PAREN, 6625-00-580-1918, 00-580-1918, 6625005801918, 005801918

Instruments and Laboratory Equipment | Electrical and Electronic Properties Measuring and Testing Instruments

Supply Group (FSG) NSN Assign. NIIN
66 01 JAN 1963 00-580-1918

Cross Reference | NSN 6625-00-580-1918

Part Number Cage Code Manufacturer
I196PAREN 80063 US ARMY COMMUNICATIONS & ELECTRONICS MATERIEL READINESS

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 6625-00-580-1918

Technical Data | NSN 6625-00-580-1918

Characteristic Specifications
FREQUENCY RANGE RATING 157.000 TO 211.000 MEGAHERTZ
FREQUENCY BAND QUANTITY 3
CRYSTAL CONTROLLED FEATURE NOT PROVIDED
CALIBRATED SIGNAL OUTPUT RANGE NOT RATED
MODULATOR LOCATION INTERNAL
MODULATION TYPE PULSE
CURRENT TYPE DC
VOLTAGE RATING 1.5 VOLTS NOMINAL AND 135.0 VOLTS NOMINAL
INTERNAL BATTERY ACCOMMODATION INCLUDED
CASE MATERIAL WOOD
CASE SURFACE TREATMENT ANY ACCEPTABLE
OVERALL LENGTH 8.250 INCHES NOMINAL
OVERALL WIDTH 8.250 INCHES NOMINAL
OVERALL HEIGHT 12.500 INCHES NOMINAL
ACCESSORY COMPONENT QUANTITY 1
ACCESSORY COMPONENT NAME CONTAINER COVER
III END ITEM IDENTIFICATION TYPE NO. IE-46-A

Restrictions/Controls & Freight Information | NSN 6625-00-580-1918

Category Code Description
Hazardous Material Indicator CodePThere is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product
Demilitarization Code:ANon-Munitions List Item/ Non-Strategic List Item - Demilitarization not required.
Precious Metals Indicator Code:AItem does not contain precious metal
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Automatic Data Processing Equipment:0Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)
Category Code Description
No Freight Information