NSN 6625-00-565-8729 X424A001002, X424A-001-002, X424AOPT001002
Product Details | RADIO FREQUENCY DETECTOR
6625-00-565-8729 An electronic device which demodulates radio frequency energy and may also provide a direct current control potential.20512850045Fire Control Radar Equipment, except Airborne14300037Guided Missile Remote Control Systems58950037Miscellaneous Communication Equipment59630018Electronic Modules66250070Electrical and Electronic Properties Measuring and Testing Instruments
Part Alternates: X424A001002, X424A-001-002, X424AOPT001002, X424AOPT001-002, 6625-00-565-8729, 00-565-8729, 6625005658729, 005658729
Instruments and Laboratory Equipment | Electrical and Electronic Properties Measuring and Testing Instruments
Supply Group (FSG) | NSN Assign. | NIIN | Item Name Code (INC) |
---|---|---|---|
66 | 21 NOV 1974 | 00-565-8729 | 05474 ( DETECTOR, RADIO FREQUENCY ) |
Request a Quote
What Our Customers Say
Compare
NSNs for Compare ( up to 4 ): Add 6625-00-565-8729
Related Products | NSN 6625-00-565-8729
Technical Data | NSN 6625-00-565-8729
Characteristic | Specifications |
---|---|
CIRCUIT CONSTRUCTION TYPE | SOLID STATE |
FREQUENCY PER CHANNEL | NOT RATED |
ATTENUATION IN DECIBELS | NOT RATED |
AVERAGE POWER RATING PER CHANNEL | NOT RATED |
SIGNAL VOLTAGE RATING PER CHANNEL | NOT RATED |
OVERALL GAIN | NOT RATED |
IMPEDANCE RATING PER CHANNEL | NOT RATED |
AVERAGE LIFE MEASUREMENT | NOT RATED |
MAXIMUM OPERATING ALTITUDE RATING | NOT RATED |
OPERATING TEMP RANGE | NOT RATED |
VIBRATION RESISTANCE RANGE IN HERTZ | NOT RATED |
SHOCK RESISTANCE RATING IN GRAVITATIONAL UNITS | NOT RATED |
INCLOSURE TYPE | ENCASED |
INSTALLATION DESIGN | MODULE |
BASIC SHAPE STYLE | 1 RECTANGULAR OR SQUARE |
OVERALL LENGTH | 3.000 INCHES NOMINAL |
OVERALL HEIGHT | 1.400 INCHES MAXIMUM |
OVERALL WIDTH | 1.400 INCHES MAXIMUM |
IDENTIFICATION DESIGNATOR | X24ACPT001-002-28480 |
Restrictions/Controls & Freight Information | NSN 6625-00-565-8729
Category | Code | Description |
---|---|---|
Hazardous Material Indicator Code | P | There is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product |
Demilitarization Code: | A | Non-Munitions List Item/ Non-Strategic List Item - Demilitarization not required. |
Precious Metals Indicator Code: | U | Precious metal type is unknown |
Criticality Code: | X | The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. |
Category | Code | Description |
---|---|---|
NMF Description | 061700 | ELEC APPLIANCES/INSTRUMENTS NOI |
Less than car load rating | ||
Less than truck load rating | W | Rating Variable |
Water commodity Code | 658 | unknown |
Originating Activity Code | TX | Defense Supply Center Columbus Columbus, OH 43218 |
Air Dimension Code | A | Shipment is not a consolidation and does not exceed 72 inches in any dimension. |
Air Commodity | H | Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc. |
Air Special Handling | Z | No special handling required. |
Special Handling Code | 9 | unknonwn |
HAZMAT | ||
Type of Cargo | Z | No special type of cargo code applicable |