Product Details | PULSE GENERATOR

6625-00-503-2709 An electronic device which develops a discontinuous electrical potential with an abrupt rate of change of voltage which determines the harmonic content of the pulse train. The duration of a single pulse output is relatively short compared to the time of the recurrence cycle. See also GENERATOR, SINGLE PULSE; and GENERATOR, ELECTRONIC MARKER.20358950037Miscellaneous Communication Equipment61150041Generators and Generator Sets, Electrical66250070Electrical and Electronic Properties Measuring and Testing Instruments

Part Alternates: SCD65662, SC-D-65662, GS55039, 6625-00-503-2709, 00-503-2709, 6625005032709, 005032709

Instruments and Laboratory Equipment | Electrical and Electronic Properties Measuring and Testing Instruments

Supply Group (FSG) NSN Assign. NIIN
66 10 AUG 1966 00-503-2709

Drawings & Photos | NSN 6625-00-503-2709


Cross Reference | NSN 6625-00-503-2709

Part Number Cage Code Manufacturer
GS55039 06KW9 LUCENT TECHNOLOGIES INC DBA FEDERAL MARKETING GROUP
GS55039 3B4M0 LUCENT TECHNOLOGIES INC CORPORATE HEADQUARTERS
GS55039 64959 AMERICAN TELEPHONE AND TELEGRAPH CO
SC-D-65662 80063 US ARMY COMMUNICATIONS & ELECTRONICS MATERIEL READINESS

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 6625-00-503-2709

Technical Data | NSN 6625-00-503-2709

Characteristic Specifications
CIRCUIT CONSTRUCTION TYPE ELECTRON TUBE
FREQUENCY PER CHANNEL 40.000 MEGAHERTZ MINIMUM OPERATING CHANNEL 122.000 MEGAHERTZ MAXIMUM OPERATING CHANNEL
IMPEDANCE RATING PER CHANNEL 75.000 OHMS OUTPUT CHANNEL
PULSE PEAK AMPLITUDE PER CHANNEL 5.000 MILLIVOLTS OUTPUT CHANNEL
POLARITY PER CHANNEL NEGATIVE OPERATING CHANNEL POSITIVE OPERATING CHANNEL
PULSE REPETITION RATE PER CHANNEL 0.500 PULSES PER SECOND MINIMUM OPERATING CHANNEL 2.500 PULSES PER SECOND MAXIMUM OPERATING CHANNEL
PULSE MODULATION TYPE PER CHANNEL AMPLITUDE OPERATING CHANNEL
EXTERNAL DC OPERATING VOLTAGE IN VOLTS 150.0 NOMINAL 1ST VOLTAGE 250.0 NOMINAL 2ND VOLTAGE
EXTERNAL AC OPERATING VOLTAGE IN VOLTS 6.3 NOMINAL SINGLE VOLTAGE
OPERATING AC FREQUENCY IN HERTZ 60.0 NOMINAL SINGLE VOLTAGE
PHASE SINGLE
BASIC SHAPE STYLE 1 RECTANGULAR OR SQUARE
OVERALL LENGTH 7.000 INCHES NOMINAL
OVERALL HEIGHT 4.875 INCHES NOMINAL
OVERALL WIDTH 5.938 INCHES NOMINAL
III FSC APPLICATION DATA RADIO TRANSMITTER,EXCEPT NAVIGATION,NONAIRBORNE
MANUFACTURERS CODE 80063
DESIGN CONTROL REFERENCE SC-D-65662

Restrictions/Controls & Freight Information | NSN 6625-00-503-2709

Category Code Description
Shelf-Life Code:0Nondeteriorative
Hazardous Material Indicator CodePThere is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product
Demilitarization Code:ANon-Munitions List Item/ Non-Strategic List Item - Demilitarization not required.
Controlled Inventory Item Code:UUNCLASSIFIED
Precious Metals Indicator Code:AItem does not contain precious metal
Criticality Code:NThe item does not have a critical feature such as tolerance, fit restrictions or application. Nuclear hardness properties have not been determined (not valid for input).
Category Code Description
NMF Description 061700 ELEC APPLIANCES/INSTRUMENTS NOI
Less than car load rating M 85
Less than truck load rating W Rating Variable
Water commodity Code 658 unknown
Originating Activity Code SG 403 SCMS/GUED
5215 Thurlow St, Suite 5, Bldg 70C
Wright-Patterson AFB OH 45433
Air Dimension Code A Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Air Commodity H Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
Air Special Handling Z No special handling required.
Special Handling Code 9 unknonwn
HAZMAT
Type of Cargo Z No special type of cargo code applicable

Management | NSN 6625-00-503-2709

Category Code Description
Materiel Category and Inventory ManagerG Communications and Electronics Equipment, Electronics Materiel
Appropriation and Budget Activity2 Stock Fund Secondary Items
Management Inventory Segment1 REPARABLE ITEMS (Exclusive of Insurance and Provisioning Items.) This code will be used to identify serviceable or unserviceable items of a durable nature which when unserviceable normally can be repaired economically by depots or lower echelons of maintenance.
Specific Group/Generic Code5 Communications Systems Equipment
Weapons Systems/End Item or Homogeneous Group5ZAB-216 A/U Tower
Accounting Requirements CodeX Expendable item. An item of Army property coded with an ARC of ?X? in the AMDF. Expendable items require no formal accountability after issue from a stock record account. Commercial and fabricated items similar to items coded ?X? in the AMDF are considered expendable items.
Source of SupplyB16US Army Communications-Electronics
Command and Fort Monmouth
Fort Monmouth, NJ 07703-5016
AgencyDADepartment of the Army
Service OrganizationLLead Service - 22 (Repairable)
ReparabilityLDisposal is not authorized below wholesale/specialized repair activity level.
Acquisition Advice CodesXSEMIACTIVE ITEM-NO REPLACEMENT (NON-STOCKED ITEMS) A potentially inactive NSN which must be retained in the supply system as an item of supply because (1) stocks of the item are on hand or in use below the wholesale level and (2) the NSN is cited in equipment authorization documents TO & E, TA, TM, etc., or in-use assets are being reported. 1. Items are authorized for central procurement but not authorized for stockage at wholesale level. 2. Requisitions for in-use replacement will be authorized in accordance with individual Military Service directives. 3. Requisitions may be submitted as requirements generate. Repetitive demands may dictate an AAC change to permit wholesale stockage.
Controlled Item CodeUUNCLASSIFIED
Shelf Life Code0Nondeteriorative
Purchasing QTY
UOM
1
EA : Each