Product Details | ELECTRICAL TEST PANEL

6625-00-492-9789 A panel upon which are mounted items such as meters, switches, resistors, jacks, binding posts, and like items, It is designed to be connected to many different types of electrical parts, equipment, or circuits for testing purposes. Do not use for items having specific test applications, such as TESTER (as modified); and TEST SET (as modified).

Part Alternates: 7876657001, 787-6657-001, 6625-00-492-9789, 00-492-9789, 6625004929789, 004929789

Instruments and Laboratory Equipment | Electrical and Electronic Properties Measuring and Testing Instruments

Supply Group (FSG) NSN Assign. NIIN
66 11 FEB 1970 00-492-9789

Cross Reference | NSN 6625-00-492-9789

Part Number Cage Code Manufacturer
787-6657-001 13499 ROCKWELL COLLINS, INC. DBA GOVERNMENT SYSTEMS
787-6657-001 95105 ROCKWELL COLLINS, INC. DIV GOVERNMENT SYSTEMS - DALLAS

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 6625-00-492-9789

Technical Data | NSN 6625-00-492-9789

Characteristic Specifications
DC VOLTAGE RATING 5.0 VOLTS NOMINAL AND 12.0 VOLTS NOMINAL AND -12.0 VOLTS NOMINAL
PANEL MATERIAL ALUMINUM
OVERALL LENGTH 19.633 INCHES NOMINAL
OVERALL HEIGHT 7.600 INCHES NOMINAL
OVERALL WIDTH 0.700 INCHES NOMINAL
TEST ITEM MOUNTING ACCOMMODATION JACKS
III END ITEM IDENTIFICATION COMMUNICATION CENTRAL AN/TSC-60 (V)
III USAGE DESIGN AMPLIFIER,POWER ASSY P/N 777-5574-001
MANUFACTURERS CODE 13499
DESIGN CONTROL REFERENCE 787-6657-001

Restrictions/Controls & Freight Information | NSN 6625-00-492-9789

Category Code Description
Hazardous Material Indicator CodePThere is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product
Demilitarization Code:ANon-Munitions List Item/ Non-Strategic List Item - Demilitarization not required.
Precious Metals Indicator Code:UPrecious metal type is unknown
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Category Code Description
NMF Description 061680 ELEC WIRING PLUGS ETC SUB2
Less than car load rating
Less than truck load rating P 77.5
Water commodity Code 658 unknown
Originating Activity Code SX Oklahoma City Air Logistics Center
Tinker AFB, OK 73145-3043
Air Dimension Code A Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Air Commodity H Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
Air Special Handling Z No special handling required.
Special Handling Code Z unknonwn
HAZMAT
Type of Cargo Z No special type of cargo code applicable