NSN 6625-00-478-0597 4130310, 413-0310 , 7A22
Product Details | ELECTRICAL-ELECTRONIC TEST EQUIPMENT PLUG-IN UNIT
6625-00-478-0597 An electronic subassembly designed to be plugged into one or more basic pieces of test equipment to extend the capabilities of the basic instrument. The basic instrument cannot function without one or more plug-in units (as required) in position.20649200058Aircraft Maintenance and Repair Shop Specialized Equipment49310062Fire Control Maintenance and Repair Shop Specialized Equipment49330057Weapons Maintenance and Repair Shop Specialized Equipment49350070Guided Missile Maintenance, Repair, and Checkout Specialized Equipment66250070Electrical and Electronic Properties Measuring and Testing Instruments66350042Physical Properties Testing and Inspection
Part Alternates: 4130310, 413-0310 , 7A22, 6625-00-478-0597, 00-478-0597, 6625004780597, 004780597
Instruments and Laboratory Equipment | Electrical and Electronic Properties Measuring and Testing Instruments
Supply Group (FSG) | NSN Assign. | NIIN | Item Name Code (INC) |
---|---|---|---|
66 | 20 MAY 1970 | 00-478-0597 | 66495 ( PLUG-IN UNIT, ELECTRICAL-ELECTRONIC TEST EQUIPMENT ) |
Cross Reference | NSN 6625-00-478-0597
Part Number | Cage Code | Manufacturer |
---|---|---|
7A22 | 80009 | TEKTRONIX, INC. DBA TEKTRONIX |
Request a Quote
What Our Customers Say
Compare
Related Products | NSN 6625-00-478-0597
Technical Data | NSN 6625-00-478-0597
Characteristic | Specifications |
---|---|
UNIT TYPE | DIFFERENTIAL INPUT AMPLIFIER |
OVERALL LENGTH | 14.000 INCHES NOMINAL |
OVERALL WIDTH | 2.800 INCHES NOMINAL |
OVERALL HEIGHT | 5.000 INCHES NOMINAL |
FURNISHED ITEMS | MANUAL |
ACCESSORY COMPONENT QUANTITY | 2 |
ACCESSORY IDENTIFYING NUMBER | 070-0931-00 PART NO. |
SPECIAL FEATURES | DIFFERENTIAL AMPLIFIER PLUG IN UNIT |
III FUNCTIONAL CLASSIFICATION | AA-3.3 |
III FUNCTIONAL DESCRIPTION | PROVIDES MEASUREMENT CAPABILITIES IN BIOMEDICAL TRANSDUCERS; USED ON THE J-15/TF-33 AIRCRAFT |
III TYPE/MODEL DESIGNATION | AM-6786/U |
III REFERENCE DATA AND LITERATURE | TEKTRONIX 070-0931-00 |
III ENTRY DATE | 80-09-01 |
III FSC APPLICATION DATA | OSCILLOSCOPE,EXCEPT SPECIALLY DESIGNED |
Restrictions/Controls & Freight Information | NSN 6625-00-478-0597
Category | Code | Description |
---|---|---|
Shelf-Life Code: | 0 | Nondeteriorative |
Hazardous Material Indicator Code | P | There is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product |
Demilitarization Code: | A | Non-Munitions List Item/ Non-Strategic List Item - Demilitarization not required. |
Controlled Inventory Item Code: | 7 | NON-SENSITIVE (SRC-N/A) - UNCLASSIFIED AA&E: OR ITEMS ASSIGNED A DEMILITARIZATION CODE OTHER THAN A, B, Q, OR P FOR WHICH ANOTHER CIIC IS INAPPROPRIATE. (NOTE: THE LOSS, THEFT, UNLAWFUL DISPOSITION, AND/OR RECOVERY OF AN ITEM WITH CIIC 7 WILL BE INVESTIGATED IN ACCORDANCE WITH DOD-4000-25-2-M AND DOD 7200.14-R, VOLUME 12, CHAPTER 7). |
Electro-static Discharge Susceptible: | A | No known Electrostatic Discharge (ESD) or Electromagnetic Interference (EMI) sensitivity |
Precious Metals Indicator Code: | A | Item does not contain precious metal |
Criticality Code: | X | The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. |
Automatic Data Processing Equipment: | 0 | Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9) |
Category | Code | Description |
---|---|---|
NMF Description | 061700 | ELEC APPLIANCES/INSTRUMENTS NOI |
Less than car load rating | P | 77.5 |
Less than truck load rating | J | 100.2 |
Water commodity Code | 72D | unknown |
Originating Activity Code | SE | San Antonio Air Logistics Center Kelly AFB, TX 78241-5000 |
Air Dimension Code | A | Shipment is not a consolidation and does not exceed 72 inches in any dimension. |
Air Commodity | V | Vehicles, machinery, shop and warehouse equipment and supplies, including special tools and equipment, ground servicing and special purpose vehicles, marine equipment and supplies, repair and maintenance parts for the above. |
Air Special Handling | Z | No special handling required. |
Special Handling Code | 9 | unknonwn |
HAZMAT | ||
Type of Cargo | Z | No special type of cargo code applicable |
Management | NSN 6625-00-478-0597
Category | Code | Description |
---|---|---|
Materiel Category and Inventory Manager | L | Missiles, Missile Materiel |
Appropriation and Budget Activity | 2 | Stock Fund Secondary Items |
Management Inventory Segment | 1 | REPARABLE ITEMS (Exclusive of Insurance and Provisioning Items.) This code will be used to identify serviceable or unserviceable items of a durable nature which when unserviceable normally can be repaired economically by depots or lower echelons of maintenance. |
Specific Group/Generic Code | T | Other Electronics Equipment |
Weapons Systems/End Item or Homogeneous Group | TE | Tool Kits |
Accounting Requirements Code | X | Expendable item. An item of Army property coded with an ARC of ?X? in the AMDF. Expendable items require no formal accountability after issue from a stock record account. Commercial and fabricated items similar to items coded ?X? in the AMDF are considered expendable items. |
Source of Supply | B64 | US Army Aviation and Missile Command ATTN: AMSMI-LC-MM-C Redstone Arsenal, AL 35898-5230 |
Agency | DA | Department of the Army |
Service Organization | A | U.S. Army |
Reparability | D | When repair is beyond lower level maintenance capability, evacuate the item to depot. Disposal is not authorized below wholesale level. |
Acquisition Advice Codes | J | NOT STOCKED, CENTRALLY PROCURED # (NON-STOCKED ITEMS) IMM/Service centrally managed but not stocked item. Procurement will be initiated only after receipt of a requisition. |
Controlled Item Code | 7 | NON-SENSITIVE (SRC-N/A) - UNCLASSIFIED AA&E: OR ITEMS ASSIGNED A DEMILITARIZATION CODE OTHER THAN A, B, Q, OR P FOR WHICH ANOTHER CIIC IS INAPPROPRIATE. (NOTE: THE LOSS, THEFT, UNLAWFUL DISPOSITION, AND/OR RECOVERY OF AN ITEM WITH CIIC 7 WILL BE INVESTIGATED IN ACCORDANCE WITH DOD-4000-25-2-M AND DOD 7200.14-R, VOLUME 12, CHAPTER 7). |
Shelf Life Code | 0 | Nondeteriorative |
Purchasing | QTY UOM |
1 EA : Each |
Category | Code | Description |
---|---|---|
Price Validation | N | The current standard price in Catalog Management Data (CMD) has not analyzed or coded for LP/LM.
|
Materiel Management Aggregation Code | RH | TG:AUTO TEST EQUIPMENT/AUTO TEST SYSTEMS (ATE/ATS) (FSC RESIDUAL MMAC) |
Budget Code | Y | variousO & M:AF centrally procured equipment items. They are separate, primary end items (other than the weapon system itself) needed by a user to perform an assigned mission. They are nonexpendable items (ERRCD NF or ND) which are not consumed in use, and they do not lose their original identity during periods of use by incorporation into, or attachment to another assembly. |
Source of Supply | FLZ | Warner Robins Air Logistics Center Robins AFB, GA 31098-5609 |
Agency | DF | Department of the Air Force |
Service Organization | L | Lead Service - 22 (Repairable) |
Reparability | S | AF Equipment Management System (AFEMS) |
Acquisition Advice Codes | V | TERMINAL ITEM # Identifies items in stock, but future procurement is not authorized. Requisitions may continue to be submitted until stocks are exhausted. Preferred item National Stock Number is normally provided by application of the phrase: When Exhausted Use (NSN). Requisitions will be submitted in accordance with IMM/Service requisitioning procedures as applicable. |
Controlled Item Code | U | UNCLASSIFIED |
Shelf Life Code | 0 | Nondeteriorative |
Purchasing | QTY UOM |
1 EA : Each |
Category | Code | Description |
---|---|---|
Cognizance Codes | 7Z | General purpose electronic test equipment to support various Naval Systems Commands equipment/programs. Naval Inventory Control Point, Mechanicsburg |
Special Material ID | TE | General purpose electronic test equipment |
Special Material Content | 9 | Non-Hazardous or Non-Sensitive Item, does not require hazardous or special handling, packaging or precautions |
Source of Supply | N35 | Naval Inventory Control Point Mechanicsburg, PA 17055-0788 |
Agency | DN | Department of the Navy |
Service Organization | N | U.S. Navy |
Reparability | H | Depot Level Reparable |
Acquisition Advice Codes | J | NOT STOCKED, CENTRALLY PROCURED # (NON-STOCKED ITEMS) IMM/Service centrally managed but not stocked item. Procurement will be initiated only after receipt of a requisition. |
Controlled Item Code | 7 | NON-SENSITIVE (SRC-N/A) - UNCLASSIFIED AA&E: OR ITEMS ASSIGNED A DEMILITARIZATION CODE OTHER THAN A, B, Q, OR P FOR WHICH ANOTHER CIIC IS INAPPROPRIATE. (NOTE: THE LOSS, THEFT, UNLAWFUL DISPOSITION, AND/OR RECOVERY OF AN ITEM WITH CIIC 7 WILL BE INVESTIGATED IN ACCORDANCE WITH DOD-4000-25-2-M AND DOD 7200.14-R, VOLUME 12, CHAPTER 7). |
Shelf Life Code | 0 | Nondeteriorative |
Purchasing | QTY UOM |
1 EA : Each |