6625-00-249-5519 An item specifically designed to determine by comparison accurate input and output voltages of major electronic components. Excludes VOLTMETER and VOLTMETER, ELECTRONIC.

Part Alternates: 332A, 6625-00-249-5519, 00-249-5519, 6625002495519, 002495519

Instruments and Laboratory Equipment | Electrical and Electronic Properties Measuring and Testing Instruments

Supply Group (FSG) NSN Assign. NIIN
66 10 NOV 1969 00-249-5519

Cross Reference | NSN 6625-00-249-5519

Part Number Cage Code Manufacturer
332A 49673 DOWTY RFL INDUSTRIES INC

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 6625-00-249-5519

Technical Data | NSN 6625-00-249-5519

Characteristic Specifications
INSTRUMENT CALIBRATION RANGE 0.0 TO 11.111110 IN 1 UV STEPS,0.0 TO 11110.0 IN 10 UV STEPS,0.0 TO 1111.1110 IN 100 UV STEPS
CALIBRATION RANGE QUANTITY 3
CALIBRATION ACCURACY RATING PORM 0.003 PER CENT OF SETTING PLUS 10 UV ON 10V RANGE,PORM 0.003 PER CENT OF SETTING PLUS 20 UV ON 100V RANGE,PORM 0.003 PER CENT OF SETTING PLUS 40 UV ON 1000V RANGE
AC VOLTAGE RATING 115.0 VOLTS MINIMUM AND 230.0 VOLTS MAXIMUM
FREQUENCY RATING 50.0 HERTZ MINIMUM AND 60.0 HERTZ MAXIMUM
PHASE SINGLE
OVERALL WIDTH 19.000 INCHES NOMINAL
OVERALL HEIGHT 7.000 INCHES NOMINAL
OVERALL DEPTH 18.000 INCHES NOMINAL
MOUNTING METHOD RACK
MOUNTING CONFIGURATION STANDARD EIA RELAY RACK
MANUFACTURERS CODE 49673
DESIGN CONTROL REFERENCE 332A

Restrictions/Controls & Freight Information | NSN 6625-00-249-5519

Category Code Description
Hazardous Material Indicator CodePThere is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product
Demilitarization Code:BMunitions List Item - Mutilation (MUT) to the point of scrap required. (Formerly: Demilitarization not required. Trade Security Controls (TSCs) required at disposition.)
Precious Metals Indicator Code:UPrecious metal type is unknown
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Category Code Description
NMF Description 061700 ELEC APPLIANCES/INSTRUMENTS NOI
Less than car load rating J 100.2
Less than truck load rating W Rating Variable
Water commodity Code 72D unknown
Originating Activity Code SE San Antonio Air Logistics Center
Kelly AFB, TX 78241-5000
Air Dimension Code A Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Air Commodity
Air Special Handling Z No special handling required.
Special Handling Code 9 unknonwn
HAZMAT
Type of Cargo Z No special type of cargo code applicable