Product Details | RADIO FREQUENCY DETECTOR

6625-00-224-2431 An electronic device which demodulates radio frequency energy and may also provide a direct current control potential.20512850045Fire Control Radar Equipment, except Airborne14300037Guided Missile Remote Control Systems58950037Miscellaneous Communication Equipment59630018Electronic Modules66250070Electrical and Electronic Properties Measuring and Testing Instruments

Part Alternates: 1297034P1, 414B, 41-4B, 51011, 6625-00-224-2431, 00-224-2431, 6625002242431, 002242431

Instruments and Laboratory Equipment | Electrical and Electronic Properties Measuring and Testing Instruments

Supply Group (FSG) NSN Assign. NIIN
66 16 MAR 1970 00-224-2431

Cross Reference | NSN 6625-00-224-2431

Part Number Cage Code Manufacturer
1297034P1 94117 BAE SYSTEMS INFORMATION AND ELECTRONIC SYSTEMS INTEGRATION INC.
41-4B 04901 BOONTON ELECTRONICS CORPORATION DIV BOONTON ELECTRONICS
51011 04901 BOONTON ELECTRONICS CORPORATION DIV BOONTON ELECTRONICS

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 6625-00-224-2431

Technical Data | NSN 6625-00-224-2431

Characteristic Specifications
CIRCUIT CONSTRUCTION TYPE SOLID STATE
FREQUENCY PER CHANNEL 0.1 MEGAHERTZ MINIMUM OPERATING CHANNEL AND 12400.0 MEGAHERTZ MAXIMUM OPERATING CHANNEL
IMPEDANCE RATING PER CHANNEL 50.000 OHMS OPERATING CHANNEL
INCLOSURE TYPE ENCASED
SPECIAL FEATURES TYPE N MALE CONNECTOR; OVERLOAD RATING 300MILLIW OR P25DBM; MAX SWR FROM1.12 TO 1.6 THRU RATED FREQUENCY
III END ITEM IDENTIFICATION 42 SERIES WATTMETERS
III RELATIONSHIP TO SIMILAR EQUIPMENT 5985-01-286-3690 IS 41-4B INCLUDING41-2A CABLE
MANUFACTURERS CODE 04901
DESIGN CONTROL REFERENCE 41-4B

Restrictions/Controls & Freight Information | NSN 6625-00-224-2431

Category Code Description
Shelf-Life Code:0Nondeteriorative
Hazardous Material Indicator CodePThere is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product
Demilitarization Code:ANon-Munitions List Item/ Non-Strategic List Item - Demilitarization not required.
Controlled Inventory Item Code:UUNCLASSIFIED
Precious Metals Indicator Code:AItem does not contain precious metal
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Category Code Description
NMF Description 061700 ELEC APPLIANCES/INSTRUMENTS NOI
Less than car load rating P 77.5
Less than truck load rating J 100.2
Water commodity Code 738 unknown
Originating Activity Code SE San Antonio Air Logistics Center
Kelly AFB, TX 78241-5000
Air Dimension Code A Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Air Commodity H Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
Air Special Handling Z No special handling required.
Special Handling Code 9 unknonwn
HAZMAT
Type of Cargo Z No special type of cargo code applicable

Management | NSN 6625-00-224-2431

Category Code Description
Price ValidationN The current standard price in Catalog Management Data (CMD) has not analyzed or coded for LP/LM.
  • The price has not been analyzed or reviewed for accuracy.
  • ZOP or Standard price challenges are permissible, but must be supported with adequate justification. However, if coded for Local Purchase (LP) or Fabrication/Manufacture as indicated with an (LM) Acquisition Advice Code of ?L? or?F?,the case must be evaluated locally where purchased or fabricated.
Materiel Management Aggregation CodeRHTG:AUTO TEST EQUIPMENT/AUTO TEST SYSTEMS (ATE/ATS) (FSC RESIDUAL MMAC)
Budget CodeY variousO & M:AF centrally procured equipment items. They are separate, primary end items (other than the weapon system itself) needed by a user to perform an assigned mission. They are nonexpendable items (ERRCD NF or ND) which are not consumed in use, and they do not lose their original identity during periods of use by incorporation into, or attachment to another assembly.
Source of SupplyFLZWarner Robins Air Logistics Center
Robins AFB, GA 31098-5609
AgencyDFDepartment of the Air Force
Service OrganizationLLead Service - 22 (Repairable)
ReparabilityUAF Equipment Management System (AFEMS)
Acquisition Advice CodesVTERMINAL ITEM # Identifies items in stock, but future procurement is not authorized. Requisitions may continue to be submitted until stocks are exhausted. Preferred item National Stock Number is normally provided by application of the phrase: When Exhausted Use (NSN). Requisitions will be submitted in accordance with IMM/Service requisitioning procedures as applicable.
Controlled Item CodeUUNCLASSIFIED
Shelf Life Code0Nondeteriorative
Purchasing QTY
UOM
1
EA : Each