Product Details | ELECTRONIC TEST PLUG-IN UNIT CHASSIS

6625-00-188-3894 An open framework designed for plug-in mounting of (but does not include) modular electronic test instruments. May provide power supply, electrical and/or mechanical interface, or cooling facilities for each electronic test plug-in unit slot. Entire chassis may be rack mounted. For mounting of electrical components other than modular test equipment, see RACK, ELECTRICAL EQUIPMENT or CHASSIS, ELECTRICAL EQUIPMENT. See also OSCILLOSCOPE MAINFRAME.

Part Alternates: 1901A, 6625-00-188-3894, 00-188-3894, 6625001883894, 001883894

Instruments and Laboratory Equipment | Electrical and Electronic Properties Measuring and Testing Instruments

Supply Group (FSG) NSN Assign. NIIN
66 14 MAR 1973 00-188-3894

Cross Reference | NSN 6625-00-188-3894

Part Number Cage Code Manufacturer
1901A 1LQK8 KEYSIGHT TECHNOLOGIES, INC.
1901A 28480 HEWLETT-PACKARD COMPANY DBA HEWLETT-PACKARD CO. OR HP

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 6625-00-188-3894

Technical Data | NSN 6625-00-188-3894

Characteristic Specifications
UNIT TYPE MAIN FRAME TEST SIGNAL
OVERALL LENGTH 21.375 INCHES NOMINAL
OVERALL WIDTH 16.750 INCHES NOMINAL
OVERALL HEIGHT 5.125 INCHES NOMINAL
FURNISHED ITEMS RACK MOUNTING TABS, POWER CORD
SPECIAL FEATURES ACCOMODATES 3 INSTRUMENTS; OPERATING POWER REQUIREMENTS: 115.0 OR 230.0 VAC; 48.0/66.0 HZ; 250.0 WATTS MAX; MAINFRAME CONTAINS POWER SUPPLIES AND CABLES TO PROVIDE CONNECTIONS BETWEEN PLUG-INS; BUILT IN SHIELDING
III SUPPLEMENTARY FEATURES USES HP SERIES 1900 PLUG-INS; UNUSED SLOTS MUST BE FILLED WITH BLANK PLUG-INS, ASSIGNED NAME WAS MAINFRAME, PULSE GENERATOR
III FUNCTIONAL DESCRIPTION PULSE GENERATION WITH DIGITAL FORMATTING
MANUFACTURERS CODE 1LQK8
DESIGN CONTROL REFERENCE 1901A

Restrictions/Controls & Freight Information | NSN 6625-00-188-3894

Category Code Description
Shelf-Life Code:0Nondeteriorative
Hazardous Material Indicator CodePThere is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product
Demilitarization Code:ANon-Munitions List Item/ Non-Strategic List Item - Demilitarization not required.
Controlled Inventory Item Code:UUNCLASSIFIED
Precious Metals Indicator Code:UPrecious metal type is unknown
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Automatic Data Processing Equipment:0Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)
Category Code Description
NMF Description 061700 ELEC APPLIANCES/INSTRUMENTS NOI
Less than car load rating P 77.5
Less than truck load rating J 100.2
Water commodity Code 738 unknown
Originating Activity Code SE San Antonio Air Logistics Center
Kelly AFB, TX 78241-5000
Air Dimension Code A Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Air Commodity H Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
Air Special Handling Q Extremely fragile items including delicate instruments.
Special Handling Code 9 unknonwn
HAZMAT
Type of Cargo 3 Electrostatic Sensitive Device (ESD), subject to damage caused by electrostatic discharge. (See DoD 4500.32-R, Volume 1, Appendix A, Section I for additional information on ESD devices).

Management | NSN 6625-00-188-3894

Category Code Description
Materiel Management Aggregation CodeRHTG:AUTO TEST EQUIPMENT/AUTO TEST SYSTEMS (ATE/ATS) (FSC RESIDUAL MMAC)
Price ValidationX The current standard price has been validated and the previous price was erroneous.
  • The item was overpriced and the contractor has refunded the overcharge or DoD activities did not actually pay the previous price. The price paid is within the analyzed acceptable range.
  • If the difference from the previous price exceeds $99.99, or if the price change exceeds 500 percent and the extended value of any affected transaction exceeds $99.99, then reverse-post procedures will apply where the stock fund has overcharged unit O&M Funds. These corrections will be limited to the current fiscal year.
    • ZOP or Standard Price challenges are permissible, but should be supported by adequate justification
Budget CodeY variousO & M:AF centrally procured equipment items. They are separate, primary end items (other than the weapon system itself) needed by a user to perform an assigned mission. They are nonexpendable items (ERRCD NF or ND) which are not consumed in use, and they do not lose their original identity during periods of use by incorporation into, or attachment to another assembly.
Source of SupplyFLZWarner Robins Air Logistics Center
Robins AFB, GA 31098-5609
AgencyDFDepartment of the Air Force
Service OrganizationLLead Service - 22 (Repairable)
ReparabilitySAF Equipment Management System (AFEMS)
Acquisition Advice CodesVTERMINAL ITEM # Identifies items in stock, but future procurement is not authorized. Requisitions may continue to be submitted until stocks are exhausted. Preferred item National Stock Number is normally provided by application of the phrase: When Exhausted Use (NSN). Requisitions will be submitted in accordance with IMM/Service requisitioning procedures as applicable.
Controlled Item CodeUUNCLASSIFIED
Shelf Life Code0Nondeteriorative
Purchasing QTY
UOM
1
EA : Each