Product Details | CAPACITANCE-INDUCTANCE-RESISTANCE BRIDGE

6625-00-089-3492 An electrical test instrument designed to measure the value of an unknown capacitance, inductance, and/or resistance by comparison with calibrated known capacitances, inductances, and/or resistances.

Part Alternates: 250DA, 4300, 4600, 6625-00-089-3492, 00-089-3492, 6625000893492, 000893492

Instruments and Laboratory Equipment | Electrical and Electronic Properties Measuring and Testing Instruments

Supply Group (FSG) NSN Assign. NIIN
66 01 JUN 1967 00-089-3492

Drawings & Photos | NSN 6625-00-089-3492


Demand History | NSN 6625-00-089-3492

Part Number Request Date QTY Origin
4300 2012-03-75 2
4300 2011-05-139 1
4600 2011-03-61 1 ID

Cross Reference | NSN 6625-00-089-3492

Part Number Cage Code Manufacturer
250DA 11837 ELECTRO SCIENTIFIC INDUSTRIES INC
250DA 9Y504 ELECTRO SCIENTIFIC INDUSTRIES, INC. DBA E S I
4300 11837 ELECTRO SCIENTIFIC INDUSTRIES INC
4300 9Y504 ELECTRO SCIENTIFIC INDUSTRIES, INC. DBA E S I
4600 11837 ELECTRO SCIENTIFIC INDUSTRIES INC

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 6625-00-089-3492

Technical Data | NSN 6625-00-089-3492

Characteristic Specifications
CAPACITANCE SCALE RANGE 0.1 TO 1200000000.0 MICRO-MICROFARADS
CAPACITANCE SCALE OVERALL ACCURACY RATING IN PERCENT -0.2 TO 0.2
INDUCTANCE SCALE RANGE 0.1 TO 1200000000.0 MICROHENRIES
INDUCTANCE SCALE OVERALL ACCURACY RATING IN PERCENT -0.3 TO 0.3
RESISTANCE SCALE RANGE 0.0 TO 12.0 MEGOHMS
RESISTANCE SCALE OVERALL ACCURACY RATING IN PERCENT -0.15 TO 0.15
BALANCE INDICATOR TYPE ELECTRON-RAY TUBE
AC VOLTAGE RATING 115.0 VOLTS NOMINAL
FREQUENCY RATING 50.0 HERTZ MINIMUM AND 400.0 HERTZ MAXIMUM
PHASE SINGLE
INTERNAL BATTERY ACCOMMODATION NOT INCLUDED
OVERALL LENGTH 11.000 INCHES NOMINAL
OVERALL WIDTH 10.500 INCHES NOMINAL
OVERALL THICKNESS 9.000 INCHES NOMINAL
III REFERENCE DATA AND LITERATURE TO 33A1-6-63-1
MANUFACTURERS CODE 11837
DESIGN CONTROL REFERENCE 250DA

Restrictions/Controls & Freight Information | NSN 6625-00-089-3492

Category Code Description
Shelf-Life Code:0Nondeteriorative
Hazardous Material Indicator CodePThere is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product
Demilitarization Code:BMunitions List Item - Mutilation (MUT) to the point of scrap required. (Formerly: Demilitarization not required. Trade Security Controls (TSCs) required at disposition.)
Controlled Inventory Item Code:UUNCLASSIFIED
Precious Metals Indicator Code:AItem does not contain precious metal
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Automatic Data Processing Equipment:0Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)
Category Code Description
NMF Description 061700 ELEC APPLIANCES/INSTRUMENTS NOI
Less than car load rating D 200
Less than truck load rating J 100.2
Water commodity Code 738 unknown
Originating Activity Code SE San Antonio Air Logistics Center
Kelly AFB, TX 78241-5000
Air Dimension Code A Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Air Commodity H Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
Air Special Handling Z No special handling required.
Special Handling Code 9 unknonwn
HAZMAT
Type of Cargo 3 Electrostatic Sensitive Device (ESD), subject to damage caused by electrostatic discharge. (See DoD 4500.32-R, Volume 1, Appendix A, Section I for additional information on ESD devices).

Management | NSN 6625-00-089-3492

Category Code Description
Price ValidationN The current standard price in Catalog Management Data (CMD) has not analyzed or coded for LP/LM.
  • The price has not been analyzed or reviewed for accuracy.
  • ZOP or Standard price challenges are permissible, but must be supported with adequate justification. However, if coded for Local Purchase (LP) or Fabrication/Manufacture as indicated with an (LM) Acquisition Advice Code of ?L? or?F?,the case must be evaluated locally where purchased or fabricated.
Materiel Management Aggregation CodeRHTG:AUTO TEST EQUIPMENT/AUTO TEST SYSTEMS (ATE/ATS) (FSC RESIDUAL MMAC)
Budget CodeY variousO & M:AF centrally procured equipment items. They are separate, primary end items (other than the weapon system itself) needed by a user to perform an assigned mission. They are nonexpendable items (ERRCD NF or ND) which are not consumed in use, and they do not lose their original identity during periods of use by incorporation into, or attachment to another assembly.
Source of SupplyFLZWarner Robins Air Logistics Center
Robins AFB, GA 31098-5609
AgencyDFDepartment of the Air Force
Service OrganizationLLead Service - 22 (Repairable)
ReparabilitySAF Equipment Management System (AFEMS)
Acquisition Advice CodesVTERMINAL ITEM # Identifies items in stock, but future procurement is not authorized. Requisitions may continue to be submitted until stocks are exhausted. Preferred item National Stock Number is normally provided by application of the phrase: When Exhausted Use (NSN). Requisitions will be submitted in accordance with IMM/Service requisitioning procedures as applicable.
Controlled Item CodeUUNCLASSIFIED
Shelf Life Code0Nondeteriorative
Purchasing QTY
UOM
1
EA : Each