NSN 6625-00-005-1283 721A, 00-005-1283, 000051283
Product Details | VOLTAGE CALIBRATOR
6625-00-005-1283 An item specifically designed to determine by comparison accurate input and output voltages of major electronic components. Excludes VOLTMETER and VOLTMETER, ELECTRONIC.
Part Alternates: 721A, 6625-00-005-1283, 00-005-1283, 6625000051283, 000051283
Instruments and Laboratory Equipment | Electrical and Electronic Properties Measuring and Testing Instruments
Supply Group (FSG) | NSN Assign. | NIIN | Item Name Code (INC) |
---|---|---|---|
66 | 14 JUN 1972 | 00-005-1283 | 21329 ( CALIBRATOR, VOLTAGE ) |
Request a Quote
What Our Customers Say
Compare
NSNs for Compare ( up to 4 ): Add 6625-00-005-1283
Related Products | NSN 6625-00-005-1283
Technical Data | NSN 6625-00-005-1283
Characteristic | Specifications |
---|---|
OVERALL WIDTH | 19.500 INCHES NOMINAL |
OVERALL HEIGHT | 14.000 INCHES NOMINAL |
OVERALL DEPTH | 12.000 INCHES NOMINAL |
SPECIAL FEATURES | MFG NAME DC RATIO CALIBRATION SYSTEM |
III SUPPLEMENTARY FEATURES | C/O 6625000716219 P/N RV722, 6625009925884 P/N LC875B, 6625001680415 P/N 801 AND TEST LEADS |
III FUNCTIONAL DESCRIPTION | CALIBRATION OF DC RATIO DEVICES SUCH AS DECADE VOLTAGE DIVIDERS, VOLTBOXES, POTENTIOMETERS, BRIDGE RATIO ARMS, AND UNIVERSAL RATIO SETS |
MANUFACTURERS CODE | 11837 |
DESIGN CONTROL REFERENCE | 721A |
Restrictions/Controls & Freight Information | NSN 6625-00-005-1283
Category | Code | Description |
---|---|---|
Shelf-Life Code: | 0 | Nondeteriorative |
Hazardous Material Indicator Code | P | There is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product |
Demilitarization Code: | A | Non-Munitions List Item/ Non-Strategic List Item - Demilitarization not required. |
Controlled Inventory Item Code: | U | UNCLASSIFIED |
Electro-static Discharge Susceptible: | A | No known Electrostatic Discharge (ESD) or Electromagnetic Interference (EMI) sensitivity |
Precious Metals Indicator Code: | U | Precious metal type is unknown |
Criticality Code: | X | The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. |
Category | Code | Description |
---|---|---|
NMF Description | 061700 | ELEC APPLIANCES/INSTRUMENTS NOI |
Less than car load rating | P | 77.5 |
Less than truck load rating | J | 100.2 |
Water commodity Code | 738 | unknown |
Originating Activity Code | SE | San Antonio Air Logistics Center Kelly AFB, TX 78241-5000 |
Air Dimension Code | A | Shipment is not a consolidation and does not exceed 72 inches in any dimension. |
Air Commodity | H | Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc. |
Air Special Handling | Q | Extremely fragile items including delicate instruments. |
Special Handling Code | 9 | unknonwn |
HAZMAT | ||
Type of Cargo | Z | No special type of cargo code applicable |
Management | NSN 6625-00-005-1283
Category | Code | Description |
---|---|---|
Price Validation | N | The current standard price in Catalog Management Data (CMD) has not analyzed or coded for LP/LM.
|
Materiel Management Aggregation Code | RH | TG:AUTO TEST EQUIPMENT/AUTO TEST SYSTEMS (ATE/ATS) (FSC RESIDUAL MMAC) |
Budget Code | Y | variousO & M:AF centrally procured equipment items. They are separate, primary end items (other than the weapon system itself) needed by a user to perform an assigned mission. They are nonexpendable items (ERRCD NF or ND) which are not consumed in use, and they do not lose their original identity during periods of use by incorporation into, or attachment to another assembly. |
Source of Supply | FLZ | Warner Robins Air Logistics Center Robins AFB, GA 31098-5609 |
Agency | DF | Department of the Air Force |
Service Organization | L | Lead Service - 22 (Repairable) |
Reparability | S | AF Equipment Management System (AFEMS) |
Acquisition Advice Codes | J | NOT STOCKED, CENTRALLY PROCURED # (NON-STOCKED ITEMS) IMM/Service centrally managed but not stocked item. Procurement will be initiated only after receipt of a requisition. |
Controlled Item Code | U | UNCLASSIFIED |
Shelf Life Code | 0 | Nondeteriorative |
Purchasing | QTY UOM |
1 EA : Each |