NSN 6625-00-003-7040 AN/FRM-26, AN/ULQ-17M, ANFRM26
Product Details | OSCILLOSCOPE
6625-00-003-7040 A test instrument which is designed to give visual indications on an LCD display or a cathode ray tube of instantaneous values and variations in electrical voltage. It can also be used to indicate any quantity which can be converted into terms of electrical potential. It may include an integral pulse generator, the output of which can be used to trigger an external component; be triggered by pulses from an external source, or it may utilize an LCD display or a special type of multigun cathode ray tube and circuitry which permits a trace(s) to be sustained and displayed indefinitely, and the trace(s) may be erased when desired. For items which are not separable and operable when detached from equipment of which they are a part (built into operational equipment), see INDICATOR (2) (as modified); MONITOR (as modified); and RECORDER (as modified). See also OSCILLOGRAPH.
Part Alternates: AN/FRM-26, AN/ULQ-17M, ANFRM26, ANULQ17M, 1200B, 6625-00-003-7040, 00-003-7040, 6625000037040, 000037040
Instruments and Laboratory Equipment | Electrical and Electronic Properties Measuring and Testing Instruments
Supply Group (FSG) | NSN Assign. | NIIN | Item Name Code (INC) |
---|---|---|---|
66 | 26 MAY 1972 | 00-003-7040 | 00357 ( OSCILLOSCOPE ) |
Demand History | NSN 6625-00-003-7040
Part Number | Request Date | QTY | Origin |
---|---|---|---|
6625-00-003-7040 | 2008-11-330 | 1 | US |
Request a Quote
What Our Customers Say
Compare
Related Products | NSN 6625-00-003-7040
Technical Data | NSN 6625-00-003-7040
Characteristic | Specifications |
---|---|
SCREEN SIZE | 5 IN. |
BEAM QUANTITY | 1 |
SWEEP CIRCUITS | NOT INCLUDED |
AMPLIFIER DEFLECTION SENSITIVITY PROVISION | PROVIDED |
VERTICAL DEFLECTION SENSITIVITY VOLTAGE RATING | 0.1 MILLIVOLTS MINIMUM RMS PER INCH AND 20.0 MILLIVOLTS MAXIMUM RMS PER INCH |
HORIZONTAL DEFLECTION SENSITIVITY VOLTAGE RATING | 0.1 VOLTS MINIMUM RMS PER INCH AND 2.5 VOLTS MAXIMUM RMS PER INCH |
INPUT INTENSITY MODULATION FEATURE | PROVIDED |
VISUAL MODULATION SENSITIVITY VOLTAGE RATING | 5.0 KILOVOLTS NOMINAL |
PLATE DIRECT CONNECTION DEFLECTION SENSITIVITY PROVISION | NOT PROVIDED |
FREQUENCY RESPONSE RATING | NOT PROVIDED |
AMPLIFIER INPUT IMPEDANCE RATING PROVISION | PROVIDED |
AMPLITUDE CALIBRATING VOLTAGE WAVEFORM | SQUARE WAVE |
CALIBRATED SCREEN SCALE | INCLUDED |
TRACE STORAGE TUBE | INCLUDED |
CAMERA RECORDING DEVICE ACCOMMODATION | NOT PROVIDED |
CURRENT TYPE | AC |
VOLTAGE RATING | 115.0 VOLTS MINIMUM AND 230.0 VOLTS MAXIMUM |
FREQUENCY RATING | 50.0 HERTZ MINIMUM AND 400.0 HERTZ MAXIMUM |
PHASE | SINGLE |
OVERALL LENGTH | 18.688 INCHES NOMINAL |
OVERALL WIDTH | 8.312 INCHES NOMINAL |
OVERALL HEIGHT | 11.750 INCHES NOMINAL |
MOUNTING METHOD | RACK |
III FUNCTIONAL CLASSIFICATION | AA-3.2 |
III FUNCTIONAL DESCRIPTION | SOLID STATE DUAL CHANNEL OSCILLOSCOPE USED IN THE 500 KHZ FREQUENCY RANGE |
III REFERENCE DATA AND LITERATURE | 33A1-3-221-2 |
III ENTRY DATE | 89-04-06 |
MANUFACTURERS CODE | 1LQK8 |
DESIGN CONTROL REFERENCE | 1200B |
Restrictions/Controls & Freight Information | NSN 6625-00-003-7040
Category | Code | Description |
---|---|---|
Shelf-Life Code: | 0 | Nondeteriorative |
Hazardous Material Indicator Code | P | There is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product |
Demilitarization Code: | Q | Strategic List Item (SLI). Demilitarization not required. SLI are non-MLI(Munitions List Items) controlled by the U.S. Dept. of Commerce through the Export Administration Regulations (EAR) and indicated on the Commerce Control List (CCL). Each CCL entry is preceded by a four-digit Export Control Commerce Control List Item (CCLI) – MUT to the point of scrap required outside the United States. Inside the United States, MUT is required when the DEMIL integrity code (IC) is “3” and MUT is not required when the DEMIL IC is “6.” |
Controlled Inventory Item Code: | U | UNCLASSIFIED |
Precious Metals Indicator Code: | A | Item does not contain precious metal |
Criticality Code: | X | The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. |
Automatic Data Processing Equipment: | 0 | Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9) |
Category | Code | Description |
---|---|---|
NMF Description | 061700 | ELEC APPLIANCES/INSTRUMENTS NOI |
Less than car load rating | P | 77.5 |
Less than truck load rating | J | 100.2 |
Water commodity Code | 738 | unknown |
Originating Activity Code | SE | San Antonio Air Logistics Center Kelly AFB, TX 78241-5000 |
Air Dimension Code | A | Shipment is not a consolidation and does not exceed 72 inches in any dimension. |
Air Commodity | H | Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc. |
Air Special Handling | Q | Extremely fragile items including delicate instruments. |
Special Handling Code | 9 | unknonwn |
HAZMAT | ||
Type of Cargo | Z | No special type of cargo code applicable |
Management | NSN 6625-00-003-7040
Category | Code | Description |
---|---|---|
Price Validation | N | The current standard price in Catalog Management Data (CMD) has not analyzed or coded for LP/LM.
|
Materiel Management Aggregation Code | RH | TG:AUTO TEST EQUIPMENT/AUTO TEST SYSTEMS (ATE/ATS) (FSC RESIDUAL MMAC) |
Budget Code | Y | variousO & M:AF centrally procured equipment items. They are separate, primary end items (other than the weapon system itself) needed by a user to perform an assigned mission. They are nonexpendable items (ERRCD NF or ND) which are not consumed in use, and they do not lose their original identity during periods of use by incorporation into, or attachment to another assembly. |
Source of Supply | FLZ | Warner Robins Air Logistics Center Robins AFB, GA 31098-5609 |
Agency | DF | Department of the Air Force |
Service Organization | L | Lead Service - 22 (Repairable) |
Reparability | U | AF Equipment Management System (AFEMS) |
Acquisition Advice Codes | V | TERMINAL ITEM # Identifies items in stock, but future procurement is not authorized. Requisitions may continue to be submitted until stocks are exhausted. Preferred item National Stock Number is normally provided by application of the phrase: When Exhausted Use (NSN). Requisitions will be submitted in accordance with IMM/Service requisitioning procedures as applicable. |
Controlled Item Code | U | UNCLASSIFIED |
Shelf Life Code | 0 | Nondeteriorative |
Purchasing | QTY UOM |
1 EA : Each |