NSN 6530-01-498-2642 AUTOCLAVEPRESTIGE21007, 021278, 02-1278
Product Details | SURGICAL INSTRUMENT STERILIZER
6530-01-498-2642 00001016530000000
Part Alternates: AUTOCLAVEPRESTIGE21007, 021278, 02-1278, 21007, 6530NCM991091, 6530-01-498-2642, 01-498-2642, 6530014982642, 014982642
Medical, Dental, and Veterinary Equipment and Supplies | Hospital Furniture, Equipment, Utensils, and Supplies
Supply Group (FSG) | NSN Assign. | NIIN | Item Name Code (INC) |
---|---|---|---|
65 | 20 JUN 2002 | 01-498-2642 | 04495 ( STERILIZER, SURGICAL INSTRUMENT0 ) |
Cross Reference | NSN 6530-01-498-2642
Request a Quote
What Our Customers Say
Compare
NSNs for Compare ( up to 4 ): Add 6530-01-498-2642
Related Products | NSN 6530-01-498-2642
Technical Data | NSN 6530-01-498-2642
Characteristic | Specifications |
---|---|
VOLTAGE RATING | 120.0 VOLTS MINIMUM AND 220.0 VOLTS MAXIMUM |
WATTAGE RATING IN WATTS | 1500.0 |
HEAT TRANSFER METHOD | PRESSURE STEAM |
HEATING METHOD | ELECTRICAL |
OVERALL HEIGHT | 420.0 MILLIMETERS NOMINAL |
OVERALL WIDTH | 340.0 MILLIMETERS NOMINAL |
MATERIAL | STEEL, CORROSION RESISTING |
CLOSURE METHOD | MECHANICAL INTERLOCK SYSTEM; TOP LOADING |
UNIT PACKAGE QUANTITY | 1 |
ACCESSORY COMPONENTS AND QUANTITY | TST STERILIZING STRIPS,1 PK; GREEN SILICONE SEALING GASKET,1; PERFORMANCE TEST CERTIFICATE,1; ELECTRICAL MAINS CORD,1; INSTRUMENT FURNITURE |
SPECIAL FEATURES | 1-STEP OPERATION; FULLY AUTOMATIC CYCLE; LIGHT INDICATORS; INTERLOCK SYSTEM PREVENTS LID FROM BEING REMOVED WHILE PRESSURE REMAINS IN THE CHAMBER; EXTENDED LIFE GREEN GASKET; ELECTRONIC DETECTORS; TST INDICATOR STRIPS VERIFY CORRECT COMBINATION OF TEMPERATURE, STEAM AND TIME |
III USAGE DESIGN | STERILIZATION OF INSTRUMENTS |
III UNPACKAGED UNIT WEIGHT | 4.5 KILOGRAMS |
III PART NAME ASSIGNED BY CONTROLLING AGENCY | STERILIZER SURGICAL INSTRUMENT 120/220V |
Restrictions/Controls & Freight Information | NSN 6530-01-498-2642
Category | Code | Description |
---|---|---|
Shelf-Life Code: | 9 | 60 months |
Hazardous Material Indicator Code | N | There is no data in the HMIS and the NSN is in an FSC not generally suspected of containing hazardous materials |
Demilitarization Code: | A | Non-Munitions List Item/ Non-Strategic List Item - Demilitarization not required. |
Controlled Inventory Item Code: | U | UNCLASSIFIED |
Precious Metals Indicator Code: | A | Item does not contain precious metal |
Criticality Code: | X | The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. |
Category | Code | Description |
---|---|---|
NMF Description | 179320 | STERILIZERS NOI |
Less than car load rating | ||
Less than truck load rating | W | Rating Variable |
Water commodity Code | 651 | unknown |
Originating Activity Code | KX | Defense Supply Center Philadelphia Philiadelphia, PA 19101 |
Air Dimension Code | A | Shipment is not a consolidation and does not exceed 72 inches in any dimension. |
Air Commodity | M | Medical supplies, equipment, samples records, etc. |
Air Special Handling | Z | No special handling required. |
Special Handling Code | 9 | unknonwn |
HAZMAT | ||
Type of Cargo | Z | No special type of cargo code applicable |
Management | NSN 6530-01-498-2642
Category | Code | Description |
---|---|---|
Materiel Category and Inventory Manager | C | Medical/Dental Materiel |
Appropriation and Budget Activity | 2 | Stock Fund Secondary Items |
Management Inventory Segment | 1 | REPARABLE ITEMS (Exclusive of Insurance and Provisioning Items.) This code will be used to identify serviceable or unserviceable items of a durable nature which when unserviceable normally can be repaired economically by depots or lower echelons of maintenance. |
Specific Group/Generic Code | 0 | Medical Materiel |
Weapons Systems/End Item or Homogeneous Group | 02 | Type 2 (Extendable) Potency Dated Item |
Accounting Requirements Code | N | Nonexpendable item. An item of Army property coded with an ARC of?N?in the AMDF. Nonexpendable items require property book accountability after issue from the stock record account. Commercial and fabricated items similar to items coded ?N? in the AMDF are considered nonexpendable items. |
Source of Supply | SMS | Defense Logistics Agency Enterprise Business Systems |
Agency | DA | Department of the Army |
Service Organization | A | U.S. Army |
Reparability | O | If condemned or economically unserviceable, dispose at organizational level. |
Acquisition Advice Codes | Y | TERMINAL ITEM #(NON-STOCKED ITEMS) Future procurement is not authorized. No wholesale stock is available for issue. 1. Requisitions will not be processed to the wholesale manager. 2. Internal Service/agency requisitioning may be continued in accordance with the Service/agency requisitioning policies. |
Controlled Item Code | U | UNCLASSIFIED |
Shelf Life Code | 9 | 60 months |
Purchasing | QTY UOM |
1 EA : Each |
Category | Code | Description |
---|---|---|
Cognizance Codes | 9B | Navy-owned stocks of DLA material Naval Inventory Control Point, Mechanicsburg |
Source of Supply | SMS | Defense Logistics Agency Enterprise Business Systems |
Agency | DN | Department of the Navy |
Service Organization | N | U.S. Navy |
Acquisition Advice Codes | Y | TERMINAL ITEM #(NON-STOCKED ITEMS) Future procurement is not authorized. No wholesale stock is available for issue. 1. Requisitions will not be processed to the wholesale manager. 2. Internal Service/agency requisitioning may be continued in accordance with the Service/agency requisitioning policies. |
Controlled Item Code | U | UNCLASSIFIED |
Shelf Life Code | 9 | 60 months |
Purchasing | QTY UOM |
1 EA : Each |