NSN 6530-00-708-4250 00-708-4250, 007084250
Product Details | SURGICAL DRESSING STERILIZER
6530-00-708-4250 00001016530000000
Part Alternates: 6530-00-708-4250, 00-708-4250, 6530007084250, 007084250
Medical, Dental, and Veterinary Equipment and Supplies | Hospital Furniture, Equipment, Utensils, and Supplies
Supply Group (FSG) | NSN Assign. | NIIN | Item Name Code (INC) |
---|---|---|---|
65 | 01 JAN 1963 | 00-708-4250 | 04494 ( STERILIZER, SURGICAL DRESSING0 ) |
Request a Quote
What Our Customers Say
Compare
NSNs for Compare ( up to 4 ): Add 6530-00-708-4250
Related Products | NSN 6530-00-708-4250
Technical Data | NSN 6530-00-708-4250
Characteristic | Specifications |
---|---|
HEAT TRANSFER METHOD | PRESSURE STEAM |
HEATING METHOD | GASOLINE BURNER |
OVERALL HEIGHT | 35.250 INCHES NOMINAL |
OVERALL LENGTH | 36.000 INCHES NOMINAL |
OVERALL WIDTH | 19.500 INCHES NOMINAL |
MATERIAL | METAL, CORROSION RESISTING |
CLOSURE METHOD | HINGED DOOR SECURED BY LOCKING LEVER |
MOUNTING TYPE | TUBULAR STAND |
INSIDE LENGTH | 24.000 INCHES NOMINAL |
INSIDE DIAMETER | 16.000 INCHES NOMINAL |
ACCESSORY COMPONENTS AND QUANTITY | ASSEMBLY,STEAM RETURN RETURN LINE 1! BOX,METAL 1! DISK,STEAM REGULATOR 2! GAGE,STEAM PRESSURE 1! GAGE,WATER,W/WASHERS 1! GASKET,FILLER PLUG 1! GASKET,STERILIZER DOOR 2! GENERATOR,1! PACKING,ECCENTRIC STEM 3! PACKING,VALVE STEM 3! PLUNGER,PUMP,LEATHER2! SCRAPER,CLEANOUT 1! STOVE,GASOLINE BURNER 1! TRAP ELEMENT,THERMOSTATIC,W/WASHER 1! TRAY,PERFORATED 1! VALVE,1/2 IN. 1!VALVE,FUEL CONTROL 1 |
NONDEFINITIVE SPEC/STD DATA | 2 SIZE |
Restrictions/Controls & Freight Information | NSN 6530-00-708-4250
Category | Code | Description |
---|---|---|
Hazardous Material Indicator Code | N | There is no data in the HMIS and the NSN is in an FSC not generally suspected of containing hazardous materials |
Demilitarization Code: | A | Non-Munitions List Item/ Non-Strategic List Item - Demilitarization not required. |
Precious Metals Indicator Code: | A | Item does not contain precious metal |
Criticality Code: | X | The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. |
Category | Code | Description |
---|---|---|
NMF Description | 179320 | STERILIZERS NOI |
Less than car load rating | J | 100.2 |
Less than truck load rating | W | Rating Variable |
Water commodity Code | 534 | unknown |
Originating Activity Code | XX | |
Air Dimension Code | A | Shipment is not a consolidation and does not exceed 72 inches in any dimension. |
Air Commodity | M | Medical supplies, equipment, samples records, etc. |
Air Special Handling | Z | No special handling required. |
Special Handling Code | 9 | unknonwn |
HAZMAT | ||
Type of Cargo | Z | No special type of cargo code applicable |