NSN 6525-01-013-2201 S25328, 652500C959051, 01-013-2201
Product Details | MEDICAL X-RAY APPARATUS TUBE UNIT
6525-01-013-2201 Consists of a tube insert in a suitable housing equipped with cable receptacles; without cables.
Part Alternates: S25328, 652500C959051, 6525-01-013-2201, 01-013-2201, 6525010132201, 010132201
Medical, Dental, and Veterinary Equipment and Supplies | X-ray Equipment and Supplies: Medical, Dental, Veterinary
Supply Group (FSG) | NSN Assign. | NIIN | Item Name Code (INC) |
---|---|---|---|
65 | 27-NOV-75 | 01-013-2201 | 15750 ( TUBE UNIT, MEDICAL X-RAY APPARATUS ) |
Request a Quote
What Our Customers Say
Compare
NSNs for Compare ( up to 4 ): Add 6525-01-013-2201
Related Products | NSN 6525-01-013-2201
Technical Data | NSN 6525-01-013-2201
Characteristic | Specifications |
---|---|
PORT TO CABLE RECEPTACLE ANGLE IN DEG | 90.0 |
TUBE INSERT ANODE TYPE | HIGH SPEED ROTATING |
TARGET BASE MATERIAL | MOLYBDENUM |
TARGET FACE MATERIAL | TUNGSTEN-RHENIUM ALLOY |
TUBE INSERT FLUOROSCOPIC PEAK VOLTAGE RATING | NOT RATED |
TUBE INSERT RADIOGRAPHIC PEAK VOLTAGE RATING | 150.0 KILOVOLTS |
FOCAL SPOT QUANTITY | 2 |
FOCAL SPOT SIZE | 0.6 MM SQ; 1.2 MM SQ |
TARGET ANGLE IN DEG | 12.0 |
FEATURES PROVIDED | HIGH EMISSION |
ANODE HEAT CAPACITY RATING IN HEAT UNITS | 300000 |
HOUSING X-RAY PROTECTIVE VALUE | X-RAY PROTECTIVE VALUE OF HOUSING SHALL BE IN ACCORDANCE WITH DHEW PUBLICATION NO. FDA 75-8003 JUL 1974 |
CONTAINER TYPE | ANY ACCEPTABLE |
III UNIT OF ISSUE WEIGHT | 73.00 POUNDS |
III UNIT OF ISSUE CUBE | 1.63 CUBIC FEET |
III PART NAME ASSIGNED BY CONTROLLING AGENCY | TUBE UNIT MED X-RAY APPAR HI-SPEED TUNGSTEN-RHENIUM 150KILOVOLT |
MANUFACTURERS CODE | 81923 |
DESIGN CONTROL REFERENCE | 652500C959051 |
Restrictions/Controls & Freight Information | NSN 6525-01-013-2201
Category | Code | Description |
---|---|---|
Shelf-Life Code: | 0 | Nondeteriorative |
Hazardous Material Indicator Code | P | There is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product |
Demilitarization Code: | A | Non-Munitions List Item/ Non-Strategic List Item - Demilitarization not required. |
Controlled Inventory Item Code: | U | UNCLASSIFIED |
Precious Metals Indicator Code: | A | Item does not contain precious metal |
Criticality Code: | X | The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. |
Category | Code | Description |
---|---|---|
No Freight Information |