NSN 6525-00-616-9160 00-616-9160, 006169160
Product Details | MEDICAL X-RAY APPARATUS TUBE INSERT
6525-00-616-9160 A replacement tube insert for X-ray tubehead.
Part Alternates: 6525-00-616-9160, 00-616-9160, 6525006169160, 006169160
Medical, Dental, and Veterinary Equipment and Supplies | X-ray Equipment and Supplies: Medical, Dental, Veterinary
Supply Group (FSG) | NSN Assign. | NIIN | Item Name Code (INC) |
---|---|---|---|
65 | 01 JAN 1963 | 00-616-9160 | 14877 ( TUBE INSERT, MEDICAL X-RAY APPARATUS ) |
Request a Quote
What Our Customers Say
Compare
NSNs for Compare ( up to 4 ): Add 6525-00-616-9160
Related Products | NSN 6525-00-616-9160
Technical Data | NSN 6525-00-616-9160
Characteristic | Specifications |
---|---|
TUBE INSERT ANODE TYPE | STATIONARY |
TUBE INSERT RADIOGRAPHIC PEAK VOLTAGE RATING | 85.0 KILOVOLTS |
RADIOGRAPHIC PEAK CURRENT RATING | 15.0 MICROAMPERES |
FOCAL SPOT QUANTITY | 1 |
FOCAL SPOT SIZE | 2 MM SQ |
ACCESSORY COMPONENTS AND QUANTITY | PT OIL 1/2; GASKET 2; SET,CHART,RATING 1 |
III UNIT OF ISSUE WEIGHT | 1.25 POUNDS |
III UNIT OF ISSUE CUBE | 0.042 CUBIC FEET |
Restrictions/Controls & Freight Information | NSN 6525-00-616-9160
Category | Code | Description |
---|---|---|
Shelf-Life Code: | 0 | Nondeteriorative |
Hazardous Material Indicator Code | P | There is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product |
Demilitarization Code: | A | Non-Munitions List Item/ Non-Strategic List Item - Demilitarization not required. |
Controlled Inventory Item Code: | U | UNCLASSIFIED |
Precious Metals Indicator Code: | A | Item does not contain precious metal |
Criticality Code: | X | The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. |
Category | Code | Description |
---|---|---|
No Freight Information |
Management | NSN 6525-00-616-9160
Category | Code | Description |
---|---|---|
Cognizance Codes | 9L | Navy-owned stocks of defense medical material Naval Inventory Control Point, Mechanicsburg |
Source of Supply | S9M | Defense Supply Center Philadelphia Director of Medical Materiel Philadelphia, PA 19145 |
Agency | DN | Department of the Navy |
Service Organization | N | U.S. Navy |
Acquisition Advice Codes | Y | TERMINAL ITEM #(NON-STOCKED ITEMS) Future procurement is not authorized. No wholesale stock is available for issue. 1. Requisitions will not be processed to the wholesale manager. 2. Internal Service/agency requisitioning may be continued in accordance with the Service/agency requisitioning policies. |
Controlled Item Code | U | UNCLASSIFIED |
Shelf Life Code | 0 | Nondeteriorative |
Purchasing | QTY UOM |
1 EA : Each |