Product Details | DENTAL IMPRESSION TRAY

6520-00-562-4650 An item used for taking full impressions of the edentulous maxilla used with dental elastic materials. Excludes IMPRESSION MATERIAL, DENTAL.

Part Alternates: GGT626, 6520-00-562-4650, 00-562-4650, 6520005624650, 005624650

Medical, Dental, and Veterinary Equipment and Supplies | Dental Instruments, Equipment, and Supplies

Supply Group (FSG) NSN Assign. NIIN
65 01 JAN 1963 00-562-4650

Cross Reference | NSN 6520-00-562-4650

Part Number Cage Code Manufacturer
GGT626 81348 FEDERAL SPECIFICATIONS PROMULGATED BY GENERAL SERVICES

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 6520-00-562-4650

Technical Data | NSN 6520-00-562-4650

Characteristic Specifications
MATERIAL ALUMINUM
WIDTH 2.969 INCHES NOMINAL
FRONT TO BACK LENGTH 2.188 INCHES NOMINAL
UNIT TYPE EDENTULOUS IMPRESSION
JAW FOR WHICH DESIGNED LOWER
RIM LOCKING FEATURE NOT PROVIDED
HYDROCOLLOID USAGE FEATURE NOT INCLUDED
HANDLE TYPE INTEGRAL
NONDEFINITIVE SPEC/STD DATA II TYPE AND 2 CLASS AND 53 SIZE
MANUFACTURERS CODE 81348
NON-DEFINITIVE GOVERNMENT SPEC/STD REFERENCE GGT626

Restrictions/Controls & Freight Information | NSN 6520-00-562-4650

Category Code Description
Shelf-Life Code:Z240 months
Hazardous Material Indicator CodePThere is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product
Demilitarization Code:ANon-Munitions List Item/ Non-Strategic List Item - Demilitarization not required.
Controlled Inventory Item Code:UUNCLASSIFIED
Precious Metals Indicator Code:UPrecious metal type is unknown
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Category Code Description
No Freight Information

Management | NSN 6520-00-562-4650

Category Code Description
Cognizance Codes9LNavy-owned stocks of defense medical material
Naval Inventory Control Point, Mechanicsburg
Source of SupplyS9MDefense Supply Center Philadelphia
Director of Medical Materiel
Philadelphia, PA 19145
AgencyDNDepartment of the Navy
Service OrganizationNU.S. Navy
Acquisition Advice CodesVTERMINAL ITEM # Identifies items in stock, but future procurement is not authorized. Requisitions may continue to be submitted until stocks are exhausted. Preferred item National Stock Number is normally provided by application of the phrase: When Exhausted Use (NSN). Requisitions will be submitted in accordance with IMM/Service requisitioning procedures as applicable.
Controlled Item CodeUUNCLASSIFIED
Shelf Life CodeZ240 months
Purchasing QTY
UOM
B
EA : Each