Product Details | BONE SCREW

6515-01-590-8153 A cylindrical rod incised with one or more helical or advancing spiral threads with smooth surfaces free from nicks, dents, burrs, and scratches suitable for use in orthopedic surgery and fabricated from implant-quality corrosion resisting material which is inert and biocompatible with human bones, tissues and internal chemistry.

Part Alternates: 17047, 201.772, 201772, 6515NCM104744, 6515-01-590-8153, 01-590-8153, 6515015908153, 015908153

Medical, Dental, and Veterinary Equipment and Supplies | Medical and Surgical Instruments, Equipment, and Supplies

Supply Group (FSG) NSN Assign. NIIN
65 22 DEC 2010 01-590-8153

Cross Reference | NSN 6515-01-590-8153

Part Number Cage Code Manufacturer
17047 89875 DEFENSE LOGISTICS AGENCY DIRECTORATE OF MEDICAL MATERIEL
201.772 63075 DEPUY SYNTHES SALES INC DBA DEPUY SYNTHES TRAUMA
6515NCM104744 64616 DEFENSE MEDICAL STANDARDIZATION BOARD

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 6515-01-590-8153

Technical Data | NSN 6515-01-590-8153

Characteristic Specifications
SPECIAL FEATURES SCREW, BONE, CORTEX, 2.4 MM; SELF-TAPPING; T8 STARDRIVE RECESS; LENGTH: 22 MM; STAINLESS STEEL; COMPONENT OF INSTRUMENT AND IMPLANT SET, MINI-FRAGMENT, NSN 6515-01-586-4997; FOR FIXATION OF FRACTURES, OSTEOTOMIES, NONUNIONS, REPLANTATIONS, AND FUSIONS OF SMALL BONES AND SMALL BONE FRAGMENTS
PART NAME ASSIGNED BY CONTROLLING AGENCY SCREW BONE CORTEX 2.4MM SELF TAPPING T8 STARDRIVE RECESS MINI FRAGMENT 22MM L
END ITEM IDENTIFICATION 6515-01-586-4997 INSTRUMENT AND IMPLANT SET, MINI-FRAGMENT
OVERALL LENGTH 22.0 MILLIMETERS NOMINAL
MATERIAL AND LOCATION STEEL, CORROSION RESISTING OVERALL

Restrictions/Controls & Freight Information | NSN 6515-01-590-8153

Category Code Description
Shelf-Life Code:0Nondeteriorative
Hazardous Material Indicator CodeNThere is no data in the HMIS and the NSN is in an FSC not generally suspected of containing hazardous materials
Demilitarization Code:ANon-Munitions List Item/ Non-Strategic List Item - Demilitarization not required.
Controlled Inventory Item Code:UUNCLASSIFIED
Precious Metals Indicator Code:AItem does not contain precious metal
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Category Code Description
No Freight Information

Management | NSN 6515-01-590-8153

Category Code Description
Materiel Category and Inventory ManagerC Medical/Dental Materiel
Appropriation and Budget Activity2 Stock Fund Secondary Items
Management Inventory Segment2 NONREPARABLE ITEMS (Exclusive of Insurance and Provisioning Items). This code will be used to identify items which are not reparable.
Specific Group/Generic Code0 Medical Materiel
Weapons Systems/End Item or Homogeneous Group03Not-Potency-Dated
Accounting Requirements CodeX Expendable item. An item of Army property coded with an ARC of ?X? in the AMDF. Expendable items require no formal accountability after issue from a stock record account. Commercial and fabricated items similar to items coded ?X? in the AMDF are considered expendable items.
Source of SupplySMSDefense Logistics Agency
Enterprise Business Systems
AgencyDADepartment of the Army
Service OrganizationAU.S. Army
Acquisition Advice CodesLLOCAL PURCHASE # (NON-STOCKED ITEMS) Defense Logistics Agency (DLA)/GSA/Service/Agency-managed items authorized for local purchase as normal means of support at base, post, camp or station level. Item not stocked in wholesale distribution system of IMM/Service/Agency ICP.
Controlled Item CodeUUNCLASSIFIED
Shelf Life Code0Nondeteriorative