NSN 6515-01-583-6214 013714, 01-3714, 01-583-6214
Product Details | CHEST WALL STABILIZAION STRUT
6515-01-583-6214 An item specifically designed for internal fixation after surgery of the anterior chest wall. Bent manually to hold the sternum in a slightly overcorrected position.
Part Alternates: 013714, 01-3714, 6515-01-583-6214, 01-583-6214, 6515015836214, 015836214
Medical, Dental, and Veterinary Equipment and Supplies | Medical and Surgical Instruments, Equipment, and Supplies
Supply Group (FSG) | NSN Assign. | NIIN | Item Name Code (INC) |
---|---|---|---|
65 | 30 MAR 2010 | 01-583-6214 | 40151 ( STRUT, CHEST WALL STABILIZAION ) |
Cross Reference | NSN 6515-01-583-6214
Part Number | Cage Code | Manufacturer |
---|---|---|
01-3714 | 60650 | BIOMET MICROFIXATION, INC |
Request a Quote
What Our Customers Say
Compare
NSNs for Compare ( up to 4 ): Add 6515-01-583-6214
Related Products | NSN 6515-01-583-6214
Technical Data | NSN 6515-01-583-6214
Characteristic | Specifications |
---|---|
OVERALL LENGTH | 14.000 INCHES NOMINAL |
DESIGN DESIGNATION | FLAT FLEXIBLE CURVE |
SUPPLEMENTARY FEATURES | MINIMALLY INVASIVE SURGICAL PROCEDURE DEVELOPED BY DR. DONALD NUSS AND CALLED MIRPE |
MATERIAL AND LOCATION | STEEL, CORROSION RESISTING OVERALL |
PART NAME ASSIGNED BY CONTROLLING AGENCY | PECTUS BAR IMPLANT |
FLEXIBILITY | RIGID |
SPECIAL FEATURES | STAINLESS STEEL ASTM F138;USES PECTUS BAR EMPLATE P/N 01-3814;EACH PECTUS BAR IS BENT TO PATIENT SPECIFICATIONS WITH A PECTUS BAR BENDER BEFORE BEING IMPLANTED |
END ITEM IDENTIFICATION | PECTUS EXCAVATUM AND OTHER STERNAL DEFORMITIES |
Restrictions/Controls & Freight Information | NSN 6515-01-583-6214
Category | Code | Description |
---|---|---|
Hazardous Material Indicator Code | N | There is no data in the HMIS and the NSN is in an FSC not generally suspected of containing hazardous materials |
Demilitarization Code: | A | Non-Munitions List Item/ Non-Strategic List Item - Demilitarization not required. |
Electro-static Discharge Susceptible: | A | No known Electrostatic Discharge (ESD) or Electromagnetic Interference (EMI) sensitivity |
Precious Metals Indicator Code: | A | Item does not contain precious metal |
Criticality Code: | X | The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. |
Automatic Data Processing Equipment: | 0 | Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9) |
Category | Code | Description |
---|---|---|
No Freight Information |