Product Details | SURGICAL SUCTION HANDLE

6515-01-549-9973 An item designed for blood and/or fluid suctioning during abdominal and other types of surgery. May have control vent or preconnected conductive or non-conductive tube.

Part Alternates: 201140, 20-1140, 6515-01-549-9973, 01-549-9973, 6515015499973, 015499973

Medical, Dental, and Veterinary Equipment and Supplies | Medical and Surgical Instruments, Equipment, and Supplies

Supply Group (FSG) NSN Assign. NIIN
65 04 APR 2007 01-549-9973

Cross Reference | NSN 6515-01-549-9973

Part Number Cage Code Manufacturer
20-1140 60650 BIOMET MICROFIXATION, INC

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 6515-01-549-9973

Technical Data | NSN 6515-01-549-9973

Characteristic Specifications
OVERALL LENGTH 1.5 MILLIMETERS MINIMUM AND 2.0 MILLIMETERS MAXIMUM
SPECIAL FEATURES TROCAR HANDLE W/CANNULA; USED ON LORENZ CMF INSTRUMENTATION KIT FOR MAXILLOFACIAL SURGERY

Restrictions/Controls & Freight Information | NSN 6515-01-549-9973

Category Code Description
Hazardous Material Indicator CodeNThere is no data in the HMIS and the NSN is in an FSC not generally suspected of containing hazardous materials
Demilitarization Code:ANon-Munitions List Item/ Non-Strategic List Item - Demilitarization not required.
Electro-static Discharge Susceptible:ANo known Electrostatic Discharge (ESD) or Electromagnetic Interference (EMI) sensitivity
Precious Metals Indicator Code:AItem does not contain precious metal
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Automatic Data Processing Equipment:0Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)
Category Code Description
No Freight Information