Product Details | PORTABLE VOLUME VENTILATOR

6515-01-491-1759 An item designed to provide ventilation to a patient in transport and/or during institutional care. It may be in a transport case and provide time cycled, pressure limited, piston driven constant flow, be microprocessor controlled, with three modes, control, assist-control, synchronous intermittent mandatory ventilation providing sensitivity control, rechargeable battery, hoses, tubing, connectors, patient valve, and other related features.20265150057Medical and Surgical Instruments, Equipment, and Supplies65300053Hospital Furniture, Equipment, Utensils, and Supplies

Part Alternates: 15345, 6515-01-491-1759, 01-491-1759, 6515014911759, 014911759

Medical, Dental, and Veterinary Equipment and Supplies | Medical and Surgical Instruments, Equipment, and Supplies

Supply Group (FSG) NSN Assign. NIIN
65 15 OCT 2001 01-491-1759

Cross Reference | NSN 6515-01-491-1759

Part Number Cage Code Manufacturer
15345 0026U DUTCHMED INTERNATIONAL OOD
15345 56712 BIRD PRODUCTS CORP

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 6515-01-491-1759

Technical Data | NSN 6515-01-491-1759

Characteristic Specifications
CURRENT TYPE AC/DC
VOLTAGE IN VOLTS 250.0 AND 30.0
FREQUENCY IN HERTZ 50.0 AND 400.0
PORTABILITY PORTABLE
OVERALL LENGTH 5.000 INCHES NOMINAL
OVERALL WIDTH 12.000 INCHES NOMINAL
OVERALL HEIGHT 10.000 INCHES NOMINAL
SPECIAL FEATURES AVIAN TRANSPORT VENTILATOR; INTERNAL BATTERY 6 VOLT; OPERATING TEMP - MINUS 20 DEG C TO 40 DEG C; BREATH RATE - 0 TO 150 BPM; FLOW - 5 TO 100 LPM; INSPIRATORY TIME - 0.1 TO 3.0 SEC; TIDAL VOLUM - 50 TO 2000 ML

Restrictions/Controls & Freight Information | NSN 6515-01-491-1759

Category Code Description
Hazardous Material Indicator CodeNThere is no data in the HMIS and the NSN is in an FSC not generally suspected of containing hazardous materials
Demilitarization Code:ANon-Munitions List Item/ Non-Strategic List Item - Demilitarization not required.
Electro-static Discharge Susceptible:ANo known Electrostatic Discharge (ESD) or Electromagnetic Interference (EMI) sensitivity
Precious Metals Indicator Code:AItem does not contain precious metal
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Automatic Data Processing Equipment:0Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)
Category Code Description
No Freight Information