Product Details | PULSE OXIMETER

6515-01-489-1239 An item designed for use in monitoring oxygen saturation in the blood, pulse rate, saturated oxygen trend, and pulse amplitude. May include visual and audible alarms, preset alarm parameters, alarm silencer, reusable finger probes, and the like.

Part Alternates: 515C, 6515-01-489-1239, 01-489-1239, 6515014891239, 014891239

Medical, Dental, and Veterinary Equipment and Supplies | Medical and Surgical Instruments, Equipment, and Supplies

Supply Group (FSG) NSN Assign. NIIN
65 12 SEP 2001 01-489-1239

Cross Reference | NSN 6515-01-489-1239

Part Number Cage Code Manufacturer
515C 64793 RESPIRONICS NOVAMETRIX, LLC DIV SAME

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 6515-01-489-1239

Technical Data | NSN 6515-01-489-1239

Characteristic Specifications
PORTABILITY NONPORTABLE
MOUNTING STAND NOT PROVIDED
CARRYING CASE NOT PROVIDED
DISPOSITION AFTER INITIAL USE REUSABLE
SPECIAL FEATURES OXYGEN SATURATION: 0-100 PCT; 1 PCT RESOLUTION; 8 SECOND AVERAGING; PULSE RATE - RANGE: 30-250 BPM, ACCURACY: PORM 2 BPM, RESOLUTION: 1 BPM, 8 SECOND AVERAGING; REUSABLE Y SENSOR AND REUSABLE ADULT FINGER SENSOR; INCLUDES PLETHYSMOGRAM WITH PULSATILE WAVEFORM AND AUTOGAIN; ALERTS: AUTOMATIC AND ADJUSTABLE LIMITS FOR OXYGEN SATURATION AND PULSE RATE, AUDIO ADJUSTABLE VOLUME, 2 MIN SILENCE OR OFF (LED INDICATORS), VISUAL FLASHING NUMBERICS UPON VIOLATED LIMIT & RED ALERT BAR INDICATION OF SENSOR DISCONNECT, SENSOR OFF PATIENT, LOW SIGNAL, INSUFFICIENT LIGHT, LIGHT INTERFERENCE, PULSE OUT OF RANGE SENSOR FAULTY AND MONITOR FAULTY CONDITIONS; 7-SEGMENT LED NUMERICS; LED PULSE BAR GRAPH PROPORTIONAL TO SIGNAL STRENGTH

Restrictions/Controls & Freight Information | NSN 6515-01-489-1239

Category Code Description
Hazardous Material Indicator CodeNThere is no data in the HMIS and the NSN is in an FSC not generally suspected of containing hazardous materials
Demilitarization Code:ANon-Munitions List Item/ Non-Strategic List Item - Demilitarization not required.
Electro-static Discharge Susceptible:ANo known Electrostatic Discharge (ESD) or Electromagnetic Interference (EMI) sensitivity
Precious Metals Indicator Code:AItem does not contain precious metal
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Automatic Data Processing Equipment:0Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)
Category Code Description
No Freight Information