Product Details | PATIENT VITAL SIGNS MONITOR

6515-01-484-3638 A portable, battery operated item which may include a blood pressure cuff, adapter, universal cuff, electrocardiogram cabling, direct plug-in adapter, and other related items. Item is designed to be used to monitor a patient's blood pressure, pulse and temperature. It is also used in the intensive care unit, emergency, operating and recovery rooms.

Part Alternates: PROPAQ 202ELSP02, PROPAQ ENCORE, PROPAQ202ELSP02, PROPAQENCORE, 6515-01-484-3638, 01-484-3638, 6515014843638, 014843638

Medical, Dental, and Veterinary Equipment and Supplies | Medical and Surgical Instruments, Equipment, and Supplies

Supply Group (FSG) NSN Assign. NIIN
65 26 APR 2001 01-484-3638

Cross Reference | NSN 6515-01-484-3638

Part Number Cage Code Manufacturer
PROPAQ 202ELSP02 0M4S4 WELCH ALLYN PROTOCOL INC DBA WELCH ALLYN MONITORING DIV
PROPAQ ENCORE 0M4S4 WELCH ALLYN PROTOCOL INC DBA WELCH ALLYN MONITORING DIV

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 6515-01-484-3638

Technical Data | NSN 6515-01-484-3638

Characteristic Specifications
VOLTAGE IN VOLTS 120.0 AND 28.0
FREQUENCY IN HERTZ 50.0 OR 60.0
PORTABILITY PORTABLE
OVERALL LENGTH 5.100 INCHES NOMINAL
OVERALL WIDTH 8.200 INCHES NOMINAL
OVERALL HEIGHT 6.600 INCHES NOMINAL
SPECIAL FEATURES OPT SP02: PULSE OXIMETRY OPTION, NELLCORE OXYGEN C-LOCK PLUS SENSORS; WAVEFORM AND PULSE AMPLITUDE METER, PULSE TONE, PITCH INDICATOR; NORMAL, FAST, SLOW MODES; SATURATION RANGE, PULSE RATE MEASUREMENT RANGE AND ACCURACY; ADULT, CHILD AND NEONATAL MODES; ELECTRO SURGERY INTERFERENCE SUPPRESSION ALL CHANNELS; MEASURES ECG; NONINVASIVE/INVASIVE BLOOD PRESSURES; TEMPERATURE

Restrictions/Controls & Freight Information | NSN 6515-01-484-3638

Category Code Description
Hazardous Material Indicator CodeNThere is no data in the HMIS and the NSN is in an FSC not generally suspected of containing hazardous materials
Demilitarization Code:ANon-Munitions List Item/ Non-Strategic List Item - Demilitarization not required.
Electro-static Discharge Susceptible:ANo known Electrostatic Discharge (ESD) or Electromagnetic Interference (EMI) sensitivity
Precious Metals Indicator Code:AItem does not contain precious metal
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Automatic Data Processing Equipment:0Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)
Category Code Description
No Freight Information