NSN 6515-01-452-6178 SP020098D8001, SP0200-98-D-8001, PLUM LIFECARE 5000
Product Details | INTRAVENOUS INFUSION PUMP
6515-01-452-6178 A portable, volumetric, electric or battery operated item designed to be used for fluid administration therapy. It may also be used with other intravenous delivery systems.
Part Alternates: SP020098D8001, SP0200-98-D-8001, PLUM LIFECARE 5000, PLUMLIFECARE5000, 250707, 2507-07, 6515-01-452-6178, 01-452-6178, 6515014526178, 014526178
Medical, Dental, and Veterinary Equipment and Supplies | Medical and Surgical Instruments, Equipment, and Supplies
Supply Group (FSG) | NSN Assign. | NIIN | Item Name Code (INC) |
---|---|---|---|
65 | 02-FEB-98 | 01-452-6178 | 45742 ( PUMP, INTRAVENOUS INFUSION ) |
Request a Quote
What Our Customers Say
Compare
NSNs for Compare ( up to 4 ): Add 6515-01-452-6178
Related Products | NSN 6515-01-452-6178
Technical Data | NSN 6515-01-452-6178
Characteristic | Specifications |
---|---|
CURRENT TYPE | AC/DC |
VOLTAGE IN VOLTS | 110.0 AND 8.0 |
FREQUENCY IN HERTZ | 50.0 AND 60.0 |
LAMPHOLDER QUANTITY | ANY ACCEPTABLE |
MIRROR OVERALL DIAMETER | ANY ACCEPTABLE |
PORTABILITY | PORTABLE |
OVERALL LENGTH | 9.000 INCHES NOMINAL |
OVERALL WIDTH | 7.000 INCHES NOMINAL |
OVERALL HEIGHT | 9.000 INCHES NOMINAL |
SPECIAL FEATURES | VOLUMETRIC INFUSER SYSTEM; ONE OR TWO 0.1-99.9 ML/HR MICRO INFUSION RATE; 1-999 ML/HR MACRO INFUSION RATE; 0.1-999 ML MICRO VTBI; 1-9999 MACRO VTBI, SECONDARY INFUSIONS, -2-10 PSIG OPERATING BACKPRESSURE RANGE, CONCURRENT DELIVERY SECONDARY MODE, DISTAL AND PROXIMAL OCCLUSION ALARMS; DISTAL AND PROXIMAL AIR-IN-LINE ALARMS; NURSE CALL SYSTEM; MINIMUM/MAXIMUM ORDER QUANTITY 1 TO 49 |
III PART NAME ASSIGNED BY CONTROLLING AGENCY | PUMP IV INFUSION VOLUMETRIC INFUSER SYS ONE OR TWO CHANNEL |
Restrictions/Controls & Freight Information | NSN 6515-01-452-6178
Category | Code | Description |
---|---|---|
Shelf-Life Code: | 0 | Nondeteriorative |
Hazardous Material Indicator Code | N | There is no data in the HMIS and the NSN is in an FSC not generally suspected of containing hazardous materials |
Demilitarization Code: | A | Non-Munitions List Item/ Non-Strategic List Item - Demilitarization not required. |
Controlled Inventory Item Code: | U | UNCLASSIFIED |
Precious Metals Indicator Code: | A | Item does not contain precious metal |
Criticality Code: | X | The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. |
Category | Code | Description |
---|---|---|
No Freight Information |