NSN 6515-01-446-6766 BCI 3303 W/CONTAINER, BCI3303WCONTAINER, 980372
Product Details | PULSE OXIMETER
6515-01-446-6766 An item designed for use in monitoring oxygen saturation in the blood, pulse rate, saturated oxygen trend, and pulse amplitude. May include visual and audible alarms, preset alarm parameters, alarm silencer, reusable finger probes, and the like.
Part Alternates: BCI 3303 W/CONTAINER, BCI3303WCONTAINER, 980372, 98-0372, 3303GRC, 6515-01-446-6766, 01-446-6766, 6515014466766, 014466766
Medical, Dental, and Veterinary Equipment and Supplies | Medical and Surgical Instruments, Equipment, and Supplies
Supply Group (FSG) | NSN Assign. | NIIN | Item Name Code (INC) |
---|---|---|---|
65 | 14-JUL-97 | 01-446-6766 | 48302 ( OXIMETER, PULSE ) |
Demand History | NSN 6515-01-446-6766
Part Number | Request Date | QTY | Origin |
---|---|---|---|
6515-01-446-6766 | 2011-12-24 | 3 | DIBBS |
6515-01-446-6766 | 2011-01-31 | 1 | DIBBS |
6515-01-446-6766 | 2010-07-04 | 1 | DIBBS |
Request a Quote
What Our Customers Say
Compare
NSNs for Compare ( up to 4 ): Add 6515-01-446-6766
Related Products | NSN 6515-01-446-6766
Technical Data | NSN 6515-01-446-6766
Characteristic | Specifications |
---|---|
SPECIAL FEATURES | LIGHTWEIGHT; PORTABLE; FREESTANDING UNIT; WITH REUSABLE CONTAINER; SUITABLE FOR ATTACHMENT TO ANESTHESIA EQUIPMENT FOR USE IN SURGICAL ENVIRONMENT; 12 IN. W, 5 IN. H AND 12 IN. DEEP; 120/230 V; 50/60 HZ; AC OR BATTERY OPERATED; CONTINUOUS DIGITAL READOUT OF BOTH OXYGEN SATURATION LEVEL AND PULSE RATE; AUDIBLE/VISUAL ALARM FOR HIGH/LOW OXYGEN SATURATION, HIGH/LOW PULSE RATE AND PROBE FAILURE/DISCONNECTION; PRE-SET HIGH/LOW ALARM PARAMETERS AND USER ADJUSTABLE; ALARM SILENCER AND CONTINUOUS DISPLAY OF PARAMETERS; CAPABLE OF SIMULTANEOUS AND CONTINUOUS REAL-TIME MEASUREMENT OF ARTERIAL HEMOGLOBIN OXYGEN SATURATION, PULSE RATE AND PULSE RATE AMPLITUDE; SUPPLIED WITH ONE EACH NON-DISPOSABLE FINGER CLIP SENSOR, ONE EACH PATIENT INTERFACE SENSOR, ONE EACH PATIENT INTERFACE CABLE 9 FEET (2.74 METERS), ONE EACH BATTERY INTEGRAL WITH OXIMETER, ONE EACH POLE MOUNT SYSTEM, TWO EACH OPERATOR'S MANUAL; AEROMEDICALLY CERTIFIED FOR FIXED WING AND ROTARY AIRCRAFT |
III SUPPLEMENTARY FEATURES | ALL PROBES OR SENSORS MAY BE SPECIFICALLY SIZED FOR ADULT, PEDIATRIC, INFANT AND NEONATAL USE, OR ALLOW USE A SENSOR TYPE OF STYLE WITH REGARD TO PATIENT SIZE |
III UNIT OF ISSUE WEIGHT | 1.19 POUNDS |
III UNIT OF ISSUE CUBE | 0.026 CUBIC FEET |
III PART NAME ASSIGNED BY CONTROLLING AGENCY | OXIMETER PULSE: 120/230V 50/60HZ AC OR BATTERY OPERATED |
Restrictions/Controls & Freight Information | NSN 6515-01-446-6766
Category | Code | Description |
---|---|---|
Shelf-Life Code: | 0 | Nondeteriorative |
Hazardous Material Indicator Code | N | There is no data in the HMIS and the NSN is in an FSC not generally suspected of containing hazardous materials |
Demilitarization Code: | A | Non-Munitions List Item/ Non-Strategic List Item - Demilitarization not required. |
Controlled Inventory Item Code: | U | UNCLASSIFIED |
Precious Metals Indicator Code: | A | Item does not contain precious metal |
Criticality Code: | X | The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. |
Category | Code | Description |
---|---|---|
No Freight Information |