Product Details | URETHRAL CATHETERIZATION SET

6515-01-207-9949 A collection of items designed for use in performing urinary catheterization of adults. It is prepackaged, ready for use. May include compartment tray, catheter, drainage tube/bag, gloves, jelly, lubricating, rayon balls, clamps, underpads, disposable drapes, and other related items.

Part Alternates: P5966A, 5966A, 6515-01-207-9949, 01-207-9949, 6515012079949, 012079949

Medical, Dental, and Veterinary Equipment and Supplies | Medical and Surgical Instruments, Equipment, and Supplies

Supply Group (FSG) NSN Assign. NIIN
65 08 MAY 1985 01-207-9949

Cross Reference | NSN 6515-01-207-9949

Part Number Cage Code Manufacturer
5966A 12073 BAXTER HEALTHCARE CORP BAXTER PHARMASEAL CONVERTORS DIV
P5966A 12073 BAXTER HEALTHCARE CORP BAXTER PHARMASEAL CONVERTORS DIV

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 6515-01-207-9949

Technical Data | NSN 6515-01-207-9949

Characteristic Specifications
UNABLE TO DECODE UNABLE TO DECODE
CATHETER OVERALL LENGTH 16.000 INCHES NOMINAL
COMPONENT AND QUANTITY CLOSED DRAINAGE BAG WITH SPOUT,VALVE,9/32 INCH TUBING,VENTED PORT,1; ONE OZ. PROVIDONE IODINE SOLUTION,1; SYRINGE PREFILLED WITH STERILE WATER,1; LARGE RAYON BALLS,5; 10 CC SYRINGE PREFILLED WITH LUBE JELLY,1; LARGE WATERPROOF UNDERWRAP,1; FENESTRATED DRAPE,1; TOWEL,1; PLASTIC FORCEPS,1; TWO GLOVE WALLET,1; CALIBRATED SPECIMEN CONTAINER,1
SPECIAL FEATURES SILICONE ELASTOMER COATED FOLEY CATHETER,10 TRAYS PER CASE
STERILITY STERILE
CATHETER FRENCH SIZE 16
CATHETER PROVIDED

Restrictions/Controls & Freight Information | NSN 6515-01-207-9949

Category Code Description
Shelf-Life Code:Xmore than 60 months
Hazardous Material Indicator CodeNThere is no data in the HMIS and the NSN is in an FSC not generally suspected of containing hazardous materials
Demilitarization Code:ANon-Munitions List Item/ Non-Strategic List Item - Demilitarization not required.
Controlled Inventory Item Code:UUNCLASSIFIED
Precious Metals Indicator Code:AItem does not contain precious metal
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Automatic Data Processing Equipment:0Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)
Category Code Description
No Freight Information